메뉴 건너뛰기




Volumn 37, Issue 1, 2009, Pages 160-167

A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: A biomechanical study in a porcine model

Author keywords

All inside anterior cruciate ligament reconstructions; RetroScrew; Soft tissue graft fixation; Suture button; Tibial tunnel

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ANTERIOR CRUCIATE LIGAMENT; ARTICLE; BIODEGRADABLE IMPLANT; BIOMECHANICS; BONE DENSITOMETRY; BONE SCREW; COMPARATIVE STUDY; CONTROLLED STUDY; DUAL ENERGY X RAY ABSORPTIOMETRY; FRACTURE FIXATION; LIGAMENT SURGERY; NONHUMAN; PARAMETER; PRIORITY JOURNAL; RETROGRADE INTERFERENCE SCREW; SURGICAL TECHNIQUE; SUTURE; SUTURE BUTTON; SWINE; TENDON GRAFT; TIBIA FRACTURE;

EID: 58149231143     PISSN: 03635465     EISSN: 15523365     Source Type: Journal    
DOI: 10.1177/0363546508323747     Document Type: Article
Times cited : (72)

References (32)
  • 1
    • 1942439016 scopus 로고    scopus 로고
    • Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction
    • Ahmad CS, Gardner TR, Groh M., Arnouk J., Levine WN Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction. Am J Sports Med. 2004 ; 32: 635-640.
    • (2004) Am J Sports Med , vol.32 , pp. 635-640
    • Ahmad, C.S.1    Gardner, T.R.2    Groh, M.3    Arnouk, J.4    Levine, W.N.5
  • 2
    • 0029914015 scopus 로고    scopus 로고
    • Total and regional bone mass in female soccer players
    • Alfredson H., Nordstrom P., Lorentzon R. Total and regional bone mass in female soccer players. Calcif Tissue Int 1996 ; 59: 438-442.
    • (1996) Calcif Tissue Int , vol.59 , pp. 438-442
    • Alfredson, H.1    Nordstrom, P.2    Lorentzon, R.3
  • 3
    • 0033802701 scopus 로고    scopus 로고
    • Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque
    • Brand JC Jr, Pienkowski D., Steenlage E., Hamilton D., Johnson DL, Caborn DN Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am J Sports Med. 2000 ; 28: 705-710.
    • (2000) Am J Sports Med , vol.28 , pp. 705-710
    • Brand Jr., J.C.1    Pienkowski, D.2    Steenlage, E.3    Hamilton, D.4    Johnson, D.L.5    Caborn, D.N.6
  • 4
    • 21444442026 scopus 로고    scopus 로고
    • Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35-mm Delta Screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae
    • Chang HC, Nyland J., Nawab A., Burden R., Caborn DN Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35-mm Delta Screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae. Am J Sports Med. 2005 ; 33: 1057-1064.
    • (2005) Am J Sports Med , vol.33 , pp. 1057-1064
    • Chang, H.C.1    Nyland, J.2    Nawab, A.3    Burden, R.4    Caborn, D.N.5
  • 5
    • 0034321805 scopus 로고    scopus 로고
    • Technical note: Alternative soft-tissue graft preparation technique for cruciate ligament reconstruction
    • Charlick DA, Caborn DN Technical note: alternative soft-tissue graft preparation technique for cruciate ligament reconstruction. Arthroscopy. 2000 ; 16: E20.
    • (2000) Arthroscopy. , vol.16 , pp. 20
    • Charlick, D.A.1    Caborn, D.N.2
  • 6
    • 0035032478 scopus 로고    scopus 로고
    • Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons
    • Donahue TL, Gregersen C., Hull ML, Howell SM Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons. J Biomech Eng. 2001 ; 123: 162-169.
    • (2001) J Biomech Eng , vol.123 , pp. 162-169
    • Donahue, T.L.1    Gregersen, C.2    Hull, M.L.3    Howell, S.M.4
  • 7
    • 0025946612 scopus 로고
    • Anatomy and function of the cruciate ligaments of the domestic pig (Sus scrofa domestica): A comparison with human cruciates
    • Fuss FK Anatomy and function of the cruciate ligaments of the domestic pig (Sus scrofa domestica): a comparison with human cruciates. J Anat. 1991 ; 178: 11-20.
    • (1991) J Anat , vol.178 , pp. 11-20
    • Fuss, F.K.1
  • 8
    • 0032847047 scopus 로고    scopus 로고
    • Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction
    • Giurea M., Zorilla P., Amis AA, Aichroth P. Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med. 1999 ; 27: 621-625.
    • (1999) Am J Sports Med , vol.27 , pp. 621-625
    • Giurea, M.1    Zorilla, P.2    Amis, A.A.3    Aichroth, P.4
  • 9
    • 13444258712 scopus 로고    scopus 로고
    • Early tension loss in an anterior cruciate ligament graft: A cadaver study of four tibial fixation devices
    • Grover DM, Howell SM, Hull ML Early tension loss in an anterior cruciate ligament graft: a cadaver study of four tibial fixation devices. J Bone Joint Surg Am. 2005 ; 87: 381-390.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 381-390
    • Grover, D.M.1    Howell, S.M.2    Hull, M.L.3
  • 10
    • 0025453134 scopus 로고
    • The effects of test environment and cyclic stretching on the failure properties of human patellar tendons
    • Haut RC, Powlison AC The effects of test environment and cyclic stretching on the failure properties of human patellar tendons. J Orthop Res. 1990 ; 8: 532-540.
    • (1990) J Orthop Res , vol.8 , pp. 532-540
    • Haut, R.C.1    Powlison, A.C.2
  • 11
    • 0036329978 scopus 로고    scopus 로고
    • Bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction: An in vitro comparison of mechanical behavior under failure tensile loading and cyclic submaximal tensile loading
    • Honl M., Carrero V., Hille E., Schneider E., Morlock MM Bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction: an in vitro comparison of mechanical behavior under failure tensile loading and cyclic submaximal tensile loading. Am J Sports Med. 2002 ; 30: 549-557.
    • (2002) Am J Sports Med , vol.30 , pp. 549-557
    • Honl, M.1    Carrero, V.2    Hille, E.3    Schneider, E.4    Morlock, M.M.5
  • 12
    • 0037347246 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction, part I: Femoral site
    • Kousa P., Jarvinen TL, Vihavainen M., Kannus P., Jarvinen M. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction, part I: femoral site. Am J Sports Med. 2003 ; 31: 174-181.
    • (2003) Am J Sports Med , vol.31 , pp. 174-181
    • Kousa, P.1    Jarvinen, T.L.2    Vihavainen, M.3    Kannus, P.4    Jarvinen, M.5
  • 13
    • 0037346994 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction, part II: Tibial site
    • Kousa P., Jarvinen TL, Vihavainen M., Kannus P., Jarvinen M. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction, part II: tibial site. Am J Sports Med. 2003 ; 31: 182-188.
    • (2003) Am J Sports Med , vol.31 , pp. 182-188
    • Kousa, P.1    Jarvinen, T.L.2    Vihavainen, M.3    Kannus, P.4    Jarvinen, M.5
  • 14
    • 33746826507 scopus 로고    scopus 로고
    • No-tunnel anterior cruciate ligament reconstruction: The transtibial all-inside technique
    • Lubowitz JH: No-tunnel anterior cruciate ligament reconstruction: the transtibial all-inside technique. Arthroscopy. 2006 ; 22: 900.e1-900.e11.
    • (2006) Arthroscopy , vol.22
    • Lubowitz, J.H.1
  • 15
    • 0032950678 scopus 로고    scopus 로고
    • Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts
    • Magen HE, Howell SM, Hull ML Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med. 1999 ; 27: 35-43.
    • (1999) Am J Sports Med , vol.27 , pp. 35-43
    • Magen, H.E.1    Howell, S.M.2    Hull, M.L.3
  • 16
    • 0025271495 scopus 로고
    • Direct measurement of resultant forces in the anterior cruciate ligament: An in vitro study performed with a new experimental technique
    • Markolf KL, Gorek JF, Kabo JM, Shapiro MS Direct measurement of resultant forces in the anterior cruciate ligament: an in vitro study performed with a new experimental technique. J Bone Joint Surg Am. 1990 ; 72: 557-567.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 557-567
    • Markolf, K.L.1    Gorek, J.F.2    Kabo, J.M.3    Shapiro, M.S.4
  • 17
    • 25844508254 scopus 로고    scopus 로고
    • Anatomic graft fixation using a retrograde biointerference screw for endoscopic anterior cruciate ligament reconstruction: Single-bundle and 2-bundle techniques
    • Morgan CD, Caborn DN: Anatomic graft fixation using a retrograde biointerference screw for endoscopic anterior cruciate ligament reconstruction: single-bundle and 2-bundle techniques. Tech Orthop. 2005 ; 20: 297-302.
    • (2005) Tech Orthop , vol.20 , pp. 297-302
    • Morgan, C.D.1    Caborn, D.N.2
  • 18
    • 53949098607 scopus 로고    scopus 로고
    • Anatomic tibial graft fixation using a retrograde bio-interference screw for endoscopic anterior cruciate ligament reconstruction
    • Morgan CD, Stein DA, Leitman EH, Kalman VR Anatomic tibial graft fixation using a retrograde bio-interference screw for endoscopic anterior cruciate ligament reconstruction. Arthroscopy. 2002 ; 18: E38.
    • (2002) Arthroscopy. , vol.18 , pp. 38
    • Morgan, C.D.1    Stein, D.A.2    Leitman, E.H.3    Kalman, V.R.4
  • 19
    • 0035121512 scopus 로고    scopus 로고
    • Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation
    • Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med. 2001 ; 29: 67-71.
    • (2001) Am J Sports Med , vol.29 , pp. 67-71
    • Nagarkatti, D.G.1    McKeon, B.P.2    Donahue, B.S.3    Fulkerson, J.P.4
  • 20
    • 0033967975 scopus 로고    scopus 로고
    • Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction: Biomechanical evaluation with cyclic elongation
    • Bristol, Avon).
    • Nakano H., Yasuda K., Tohyama H., Yamanaka M., Wada T., Kaneda K. Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction: biomechanical evaluation with cyclic elongation. Clin Biomech (Bristol, Avon). 2000 ; 15: 188-195.
    • (2000) Clin Biomech , vol.15 , pp. 188-195
    • Nakano, H.1    Yasuda, K.2    Tohyama, H.3    Yamanaka, M.4    Wada, T.5    Kaneda, K.6
  • 21
    • 0037269438 scopus 로고    scopus 로고
    • Modeling elite male athletes' peripheral bone mass, assessed using regional dual x-ray absorptiometry
    • Nevill AM, Holder RL, Stewart AD Modeling elite male athletes' peripheral bone mass, assessed using regional dual x-ray absorptiometry. Bone. 2003 ; 32: 62-68.
    • (2003) Bone , vol.32 , pp. 62-68
    • Nevill, A.M.1    Holder, R.L.2    Stewart, A.D.3
  • 22
    • 0029857872 scopus 로고    scopus 로고
    • Site-specific bone mass differences of the lower extremities in 17-year-old ice hockey players
    • Nordstrom P., Lorentzon R. Site-specific bone mass differences of the lower extremities in 17-year-old ice hockey players. Calcif Tissue Int. 1996 ; 59: 443-448.
    • (1996) Calcif Tissue Int , vol.59 , pp. 443-448
    • Nordstrom, P.1    Lorentzon, R.2
  • 23
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions
    • Noyes FR, Butler DL, Grood ES, Zernicke RF, Hefzy MS Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am. 1984 ; 66: 344-352.
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 344-352
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3    Zernicke, R.F.4    Hefzy, M.S.5
  • 24
    • 0029916205 scopus 로고    scopus 로고
    • Comparison of failure strength between metallic and absorbable interference screws: Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference
    • Pena F., Grontvedt T., Brown GA, Aune AK, Engebretsen L. Comparison of failure strength between metallic and absorbable interference screws: influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference. Am J Sports Med. 1996 ; 24: 329-334.
    • (1996) Am J Sports Med , vol.24 , pp. 329-334
    • Pena, F.1    Grontvedt, T.2    Brown, G.A.3    Aune, A.K.4    Engebretsen, L.5
  • 25
    • 0035085342 scopus 로고    scopus 로고
    • Quantitative ultrasound of the tibia depends on both cortical density and thickness
    • Prevrhal S., Fuerst T., Fan B., et al. Quantitative ultrasound of the tibia depends on both cortical density and thickness. Osteoporos Int. 2001 ; 12: 28-34.
    • (2001) Osteoporos Int , vol.12 , pp. 28-34
    • Prevrhal, S.1    Fuerst, T.2    Fan, B.3
  • 26
    • 0036524466 scopus 로고    scopus 로고
    • Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading
    • Scheffler SU, Sudkamp NP, Gockenjan A., Hoffmann RF, Weiler A. Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy. 2002 ; 18: 304-315.
    • (2002) Arthroscopy , vol.18 , pp. 304-315
    • Scheffler, S.U.1    Sudkamp, N.P.2    Gockenjan, A.3    Hoffmann, R.F.4    Weiler, A.5
  • 27
    • 0031730815 scopus 로고    scopus 로고
    • Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model
    • Seil R., Rupp S., Krauss PW, Benz A., Kohn DM Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med. 1998 ; 26: 815-819.
    • (1998) Am J Sports Med , vol.26 , pp. 815-819
    • Seil, R.1    Rupp, S.2    Krauss, P.W.3    Benz, A.4    Kohn, D.M.5
  • 28
    • 0028198578 scopus 로고
    • Anterior cruciate ligament graft fixation: Comparison of hamstring and patellar tendon grafts
    • Steiner ME, Hecker AT, Brown CH Jr, Hayes WC Anterior cruciate ligament graft fixation: comparison of hamstring and patellar tendon grafts. Am J Sports Med. 1994 ; 22: 240-246.
    • (1994) Am J Sports Med , vol.22 , pp. 240-246
    • Steiner, M.E.1    Hecker, A.T.2    Brown Jr., C.H.3    Hayes, W.C.4
  • 29
    • 33744488253 scopus 로고    scopus 로고
    • Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: A biomechanical study in porcine tibial bone
    • Tetsumura S., Fujita A., Nakajima M., Abe M. Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: a biomechanical study in porcine tibial bone. J Orthop Sci. 2006 ; 11: 278-282.
    • (2006) J Orthop Sci , vol.11 , pp. 278-282
    • Tetsumura, S.1    Fujita, A.2    Nakajima, M.3    Abe, M.4
  • 30
    • 0031885152 scopus 로고    scopus 로고
    • Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws
    • Weiler A., Windhagen HJ, Raschke MJ, Laumeyer A., Hoffmann RF Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med. 1998 ; 26: 119-126.
    • (1998) Am J Sports Med , vol.26 , pp. 119-126
    • Weiler, A.1    Windhagen, H.J.2    Raschke, M.J.3    Laumeyer, A.4    Hoffmann, R.F.5
  • 31
    • 0033000311 scopus 로고    scopus 로고
    • Mechanical testing of ligament fixation devices
    • Weiss JA, Paulos LE: Mechanical testing of ligament fixation devices. Tech Orthop. 1999 ; 14: 14-21.
    • (1999) Tech Orthop , vol.14 , pp. 14-21
    • Weiss, J.A.1    Paulos, L.E.2
  • 32
    • 0032727741 scopus 로고    scopus 로고
    • The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions
    • Yamanaka M., Yasuda K., Tohyama H., Nakano H., Wada T. The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions. Am J Sports Med. 1999 ; 27: 772-777.
    • (1999) Am J Sports Med , vol.27 , pp. 772-777
    • Yamanaka, M.1    Yasuda, K.2    Tohyama, H.3    Nakano, H.4    Wada, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.