메뉴 건너뛰기




Volumn 22, Issue 8, 2006, Pages 900.e1-900.e11

No-Tunnel Anterior Cruciate Ligament Reconstruction: The Transtibial All-Inside Technique

Author keywords

ACL; All inside; Minimally invasive; No incision; Retrocutter; Retrodrill

Indexed keywords

NITINOL;

EID: 33746826507     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2006.06.003     Document Type: Article
Times cited : (65)

References (16)
  • 1
    • 0002124459 scopus 로고
    • Knee injuries
    • Crenshaw A.H. (Ed), Mosby Year Book, St. Louis
    • Sisk D.T. Knee injuries. In: Crenshaw A.H. (Ed). Campbell's operative orthopaedics. Ed 8. (1992), Mosby Year Book, St. Louis 1487-1632
    • (1992) Campbell's operative orthopaedics. Ed 8. , pp. 1487-1632
    • Sisk, D.T.1
  • 2
    • 0003348990 scopus 로고
    • Arthroscopy of lower extremity
    • Crenshaw A.H. (Ed), Mosby Year Book, St. Louis
    • Miller R.H. Arthroscopy of lower extremity. In: Crenshaw A.H. (Ed). Campbell's operative orthopaedics. Ed 8. (1992), Mosby Year Book, St. Louis 1787-1864
    • (1992) Campbell's operative orthopaedics. Ed 8. , pp. 1787-1864
    • Miller, R.H.1
  • 3
    • 0028788134 scopus 로고
    • Isometry testing for anterior cruciate ligament reconstruction revisited
    • Morgan C.D., Kalman V.H., and Grawl D. Isometry testing for anterior cruciate ligament reconstruction revisited. Arthroscopy 11 (1995) 647-659
    • (1995) Arthroscopy , vol.11 , pp. 647-659
    • Morgan, C.D.1    Kalman, V.H.2    Grawl, D.3
  • 4
    • 0012545054 scopus 로고
    • The all-inside ACL reconstruction
    • Arthrex Inc, Naples, Fla
    • Morgan C.D. The all-inside ACL reconstruction. Operative technique manual (1995), Arthrex Inc, Naples, Fla
    • (1995) Operative technique manual
    • Morgan, C.D.1
  • 5
    • 0031466307 scopus 로고    scopus 로고
    • All-inside anterior cruciate ligament reconstruction using a semitendinosus tendon and soft threaded biodegradable interference screw fixation
    • Stahelin A., and Weiler A. All-inside anterior cruciate ligament reconstruction using a semitendinosus tendon and soft threaded biodegradable interference screw fixation. Arthroscopy 13 (1997) 773-779
    • (1997) Arthroscopy , vol.13 , pp. 773-779
    • Stahelin, A.1    Weiler, A.2
  • 6
    • 53949098607 scopus 로고    scopus 로고
    • Anatomic tibial graft fixation using a retrograde bio-interference screw for endoscopic anterior cruciate ligament reconstruction
    • Morgan C.D., Stein D.A., Leitman E.H., and Kalman V.H. Anatomic tibial graft fixation using a retrograde bio-interference screw for endoscopic anterior cruciate ligament reconstruction. Arthroscopy 18 (2002) E38
    • (2002) Arthroscopy , vol.18
    • Morgan, C.D.1    Stein, D.A.2    Leitman, E.H.3    Kalman, V.H.4
  • 7
    • 25844507008 scopus 로고    scopus 로고
    • My technique in femoral tunnel preparation. The "Retro-Drill" technique
    • Puddu G., and Cerullo G. My technique in femoral tunnel preparation. The "Retro-Drill" technique. Tech Orthop 20 (2005) 224-227
    • (2005) Tech Orthop , vol.20 , pp. 224-227
    • Puddu, G.1    Cerullo, G.2
  • 8
    • 0028871306 scopus 로고
    • Endoscopic anterior cruciate ligament reconstruction. Modified technique and radiographic review
    • O'Donnell J.B., and Scerpella T.A. Endoscopic anterior cruciate ligament reconstruction. Modified technique and radiographic review. Arthroscopy 11 (1995) 577-584
    • (1995) Arthroscopy , vol.11 , pp. 577-584
    • O'Donnell, J.B.1    Scerpella, T.A.2
  • 9
    • 0028308770 scopus 로고
    • Bone tunnel enlargement after anterior cruciate ligament replacement
    • Fahey M., and Indelicato P. Bone tunnel enlargement after anterior cruciate ligament replacement. Am J Sports Med 22 (1994) 410-414
    • (1994) Am J Sports Med , vol.22 , pp. 410-414
    • Fahey, M.1    Indelicato, P.2
  • 10
    • 0028039953 scopus 로고
    • Anterior cruciate ligament reconstruction with patellar tendon-An ex vivo study of wear-related damage and failure at the femoral tunnel
    • Graf B., Henry J., Rothenberg M., and Vanderby R. Anterior cruciate ligament reconstruction with patellar tendon-An ex vivo study of wear-related damage and failure at the femoral tunnel. Am J Sports Med 22 (1994) 181-185
    • (1994) Am J Sports Med , vol.22 , pp. 181-185
    • Graf, B.1    Henry, J.2    Rothenberg, M.3    Vanderby, R.4
  • 11
    • 0012437947 scopus 로고
    • The effect of the anterior cruciate ligament graft fixation level on knee stability
    • Ishibashi Y., Rudy T., Kim H., Fu F., and Woo S. The effect of the anterior cruciate ligament graft fixation level on knee stability. Arthroscopy 11 (1995) 373
    • (1995) Arthroscopy , vol.11 , pp. 373
    • Ishibashi, Y.1    Rudy, T.2    Kim, H.3    Fu, F.4    Woo, S.5
  • 12
    • 0030912837 scopus 로고    scopus 로고
    • The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability. Evaluation using a robotic testing system
    • Ishibashi Y., Rudy T., Livesay G., et al. The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability. Evaluation using a robotic testing system. Arthroscopy 13 (1997) 177-182
    • (1997) Arthroscopy , vol.13 , pp. 177-182
    • Ishibashi, Y.1    Rudy, T.2    Livesay, G.3
  • 13
    • 0000179464 scopus 로고
    • Radiographic tunnel changes following arthroscopic anterior cruciate ligament reconstruction
    • Schulte K., Majewski M., Irrgang J., Fu F., and Harner C. Radiographic tunnel changes following arthroscopic anterior cruciate ligament reconstruction. Am J Sports Med 30 (1995) 372-373
    • (1995) Am J Sports Med , vol.30 , pp. 372-373
    • Schulte, K.1    Majewski, M.2    Irrgang, J.3    Fu, F.4    Harner, C.5
  • 14
    • 0030034160 scopus 로고    scopus 로고
    • Comparison of inside-out and outside-in interference screw fixation of anterior cruciate ligament surgery in a bovine knee
    • Bryan J., Bach B., Bush-Joseph C., Fisher I., and Hsu K. Comparison of inside-out and outside-in interference screw fixation of anterior cruciate ligament surgery in a bovine knee. Arthroscopy 12 (1996) 76-86
    • (1996) Arthroscopy , vol.12 , pp. 76-86
    • Bryan, J.1    Bach, B.2    Bush-Joseph, C.3    Fisher, I.4    Hsu, K.5
  • 15
    • 0028917810 scopus 로고
    • Assessment of initial fixation of endoscopic interference femoral screws with divergent and parallel placement
    • Lemos M.J., Jackson D.W., Lee T.Q., and Simon T.M. Assessment of initial fixation of endoscopic interference femoral screws with divergent and parallel placement. Arthroscopy 11 (1995) 37-41
    • (1995) Arthroscopy , vol.11 , pp. 37-41
    • Lemos, M.J.1    Jackson, D.W.2    Lee, T.Q.3    Simon, T.M.4
  • 16
    • 0029009214 scopus 로고
    • The effect of Kurosaka screw divergence on the holding strength of bone-tendon-bone grafts
    • Pierz K., Baltz M., and Fulkerson J. The effect of Kurosaka screw divergence on the holding strength of bone-tendon-bone grafts. Am J Sports Med 23 (1995) 332-335
    • (1995) Am J Sports Med , vol.23 , pp. 332-335
    • Pierz, K.1    Baltz, M.2    Fulkerson, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.