메뉴 건너뛰기




Volumn , Issue , 2008, Pages 382-387

The design of a wireless power transmission mechanism for locomotion in active medical inspection MEMS

Author keywords

[No Author keywords available]

Indexed keywords

AGILENT; AUTONOMOUS LOCOMOTIONS; CAPSULE ENDOSCOPES; CLINICAL USES; DROP OUTS; EDA TOOLS; EXTERNAL CONTROLS; IMPEDANCE MATCHING NETWORKS; IN-VIVO; MATHEMATICAL ANALYSES; MEDICAL PRACTICES; MICRO MOTORS; MINIMALLY INVASIVE; MOS FETS; POWER CABLE CONNECTIONS; POWER CABLES; POWER SUPPLY SYSTEMS; POWER TRANSMISSION SYSTEMS; REAL TIMES; RECTIFIER CIRCUITS; RFID TAGS; SIMULATION RESULTS; SMALL SIZES; SYSTEM DESIGNS; VOLTAGE MULTIPLIERS; WIRELESS POWER TRANSMISSIONS; WORKING FREQUENCIES;

EID: 58149186856     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SEC.2008.58     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 3
    • 58149196852 scopus 로고    scopus 로고
    • Y. K. ELIAKIM R. A novel diagnostic tool for detecting oesophageal pathology: the pillcam oesophageal video capsule. Alimentaiy pharmacology and therapeutics, 20.
    • Y. K. ELIAKIM R. A novel diagnostic tool for detecting oesophageal pathology: the pillcam oesophageal video capsule. Alimentaiy pharmacology and therapeutics, 20.
  • 4
    • 13544263366 scopus 로고    scopus 로고
    • Brief overview of biomicronano technologies
    • January
    • P. L. Gourley. Brief overview of biomicronano technologies. Biotechnol.Prog, pages 2-10, January 2005.
    • (2005) Biotechnol.Prog , pp. 2-10
    • Gourley, P.L.1
  • 7
    • 0034576886 scopus 로고    scopus 로고
    • The development of the swallowable video capsule (m2a)
    • G. Meron. The development of the swallowable video capsule (m2a). Gastrointestinal Endoscopy, 6:817C819, 2000.
    • (2000) Gastrointestinal Endoscopy , vol.6 , Issue.C819 , pp. 817
    • Meron, G.1
  • 8
    • 34147175051 scopus 로고    scopus 로고
    • Wireless capsule endoscopy:from diagnostic devices to multipurpose robotic systems biomedical microdevices
    • April
    • A. Moglia, A. Menciassi, M. O. Schurr, and P. Dario. Wireless capsule endoscopy:from diagnostic devices to multipurpose robotic systems biomedical microdevices. Biomedical Microdevices, 9:235-243, April 2007.
    • (2007) Biomedical Microdevices , vol.9 , pp. 235-243
    • Moglia, A.1    Menciassi, A.2    Schurr, M.O.3    Dario, P.4
  • 9
    • 58149201626 scopus 로고    scopus 로고
    • NAMIKI Corporation
    • NAMIKI Corporation. http://www.namiki.com.
  • 10
    • 0034249962 scopus 로고    scopus 로고
    • Design of miniature parallel manipulators for integration in a self-propelling endoscope
    • Aug
    • J. Peirs, D. Reynaerts, and H. V. Brussel. Design of miniature parallel manipulators for integration in a self-propelling endoscope. Sensors and Actuators, 85:409-417, Aug. 2000.
    • (2000) Sensors and Actuators , vol.85 , pp. 409-417
    • Peirs, J.1    Reynaerts, D.2    Brussel, H.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.