메뉴 건너뛰기




Volumn 37, Issue 2, 2009, Pages 149-155

Two-year clinical evaluation of one-step self-etch systems in non-carious cervical lesions

Author keywords

Non carious cervical lesions; One step self etch; Randomized controlled trial; Resin composite; Two year clinical evaluation

Indexed keywords

CLEARFIL AP X; CLEARFIL AP-X; CLEARFIL FLOW FX; CLEARFIL S3 BOND; DENTIN BONDING AGENT; G BOND; G-BOND; METHACRYLIC ACID DERIVATIVE; POLYMETHACRYLIC ACID DERIVATIVE; RESIN; RESIN CEMENT;

EID: 58149173976     PISSN: 03005712     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jdent.2008.10.008     Document Type: Article
Times cited : (40)

References (40)
  • 3
    • 34248519225 scopus 로고    scopus 로고
    • One-year clinical evaluation of five single-step self-etch adhesive systems in non-carious cervical lesions
    • Kurokawa H., Miyazaki M., Takamizawa T., Rikuta A., Tsubota K., and Uekusa S. One-year clinical evaluation of five single-step self-etch adhesive systems in non-carious cervical lesions. Dental Materials Journal 26 (2007) 14-20
    • (2007) Dental Materials Journal , vol.26 , pp. 14-20
    • Kurokawa, H.1    Miyazaki, M.2    Takamizawa, T.3    Rikuta, A.4    Tsubota, K.5    Uekusa, S.6
  • 4
    • 34249886039 scopus 로고    scopus 로고
    • Clinical trial of G-Bond all-in-one adhesive and Gradia Direct resin composite in non-carious cervical lesions-results at 1 year
    • Burrow M.F., and Tyas M.J. Clinical trial of G-Bond all-in-one adhesive and Gradia Direct resin composite in non-carious cervical lesions-results at 1 year. Journal of Dentistry 35 (2007) 623-625
    • (2007) Journal of Dentistry , vol.35 , pp. 623-625
    • Burrow, M.F.1    Tyas, M.J.2
  • 6
    • 34249290579 scopus 로고    scopus 로고
    • Microleakage of cervical resin composites restored with one-step self-etch systems
    • Abstr. No
    • Kubo S., Yokota H., Yokota H., and Hayashi Y. Microleakage of cervical resin composites restored with one-step self-etch systems. Journal of Dental Research 84 (2005) 3105 Abstr. No
    • (2005) Journal of Dental Research , vol.84 , pp. 3105
    • Kubo, S.1    Yokota, H.2    Yokota, H.3    Hayashi, Y.4
  • 7
    • 34547356439 scopus 로고    scopus 로고
    • Micro-tensile and micro-shear bond strengths of current self-etch adhesives to enamel and dentin
    • Ishikawa A., Shimada Y., Foxton R.M., and Tagami J. Micro-tensile and micro-shear bond strengths of current self-etch adhesives to enamel and dentin. American Journal of Dentistry 20 (2007) 161-166
    • (2007) American Journal of Dentistry , vol.20 , pp. 161-166
    • Ishikawa, A.1    Shimada, Y.2    Foxton, R.M.3    Tagami, J.4
  • 11
    • 34447633340 scopus 로고    scopus 로고
    • Effects of solvent drying time on micro-shear bond strength and mechanical properties of two self-etching adhesive systems
    • Sadr A., Shimada Y., and Tagami J. Effects of solvent drying time on micro-shear bond strength and mechanical properties of two self-etching adhesive systems. Dental materials 23 (2007) 1114-1119
    • (2007) Dental materials , vol.23 , pp. 1114-1119
    • Sadr, A.1    Shimada, Y.2    Tagami, J.3
  • 12
    • 17844399811 scopus 로고    scopus 로고
    • A randomized controlled study evaluating the effectiveness of a two-step self-etch adhesive with and without selective phosphoric-acid etching of enamel
    • Van Meerbeek B., Kanumilli P., De Munck J., Van Landuyt K., Lambrechts P., and Peumans M. A randomized controlled study evaluating the effectiveness of a two-step self-etch adhesive with and without selective phosphoric-acid etching of enamel. Dental Materials 21 (2005) 375-383
    • (2005) Dental Materials , vol.21 , pp. 375-383
    • Van Meerbeek, B.1    Kanumilli, P.2    De Munck, J.3    Van Landuyt, K.4    Lambrechts, P.5    Peumans, M.6
  • 13
    • 58149144829 scopus 로고    scopus 로고
    • Council on Dental Materials, Instruments and Equipment. Revised American Dental Association acceptance program guidelines for dentin and enamel adhesive materials. Chicago: American Dental Association; 1994.
    • Council on Dental Materials, Instruments and Equipment. Revised American Dental Association acceptance program guidelines for dentin and enamel adhesive materials. Chicago: American Dental Association; 1994.
  • 15
    • 0036823699 scopus 로고    scopus 로고
    • Three-year clinical evaluation of One-step in non-carious cervical lesions
    • Tyas M.J., and Burrow M.F. Three-year clinical evaluation of One-step in non-carious cervical lesions. American Journal of Dentistry 15 (2002) 309-311
    • (2002) American Journal of Dentistry , vol.15 , pp. 309-311
    • Tyas, M.J.1    Burrow, M.F.2
  • 16
    • 31344479350 scopus 로고    scopus 로고
    • Five-year clinical evaluation of two adhesive systems in non-carious cervical lesions
    • Kubo S., Kawasaki K., Yokota H., and Hayashi Y. Five-year clinical evaluation of two adhesive systems in non-carious cervical lesions. Journal of Dentistry 34 (2006) 97-105
    • (2006) Journal of Dentistry , vol.34 , pp. 97-105
    • Kubo, S.1    Kawasaki, K.2    Yokota, H.3    Hayashi, Y.4
  • 17
    • 33846680063 scopus 로고    scopus 로고
    • 10-year clinical evaluation of a self-etching adhesive system
    • Akimoto N., Takamizu M., and Momoi Y. 10-year clinical evaluation of a self-etching adhesive system. Operative Dentistry 32 (2007) 3-10
    • (2007) Operative Dentistry , vol.32 , pp. 3-10
    • Akimoto, N.1    Takamizu, M.2    Momoi, Y.3
  • 18
    • 38349133718 scopus 로고    scopus 로고
    • Five-year clinical evaluation of One-Up Bond F in non-carious cervical lesions
    • Burrow M.F., and Tyas M.J. Five-year clinical evaluation of One-Up Bond F in non-carious cervical lesions. American Journal of Dentistry 20 (2007) 361-364
    • (2007) American Journal of Dentistry , vol.20 , pp. 361-364
    • Burrow, M.F.1    Tyas, M.J.2
  • 20
    • 33646133636 scopus 로고    scopus 로고
    • Effect of air-drying time of single-step self-application self-etch adhesives on dentin bond strength
    • Chiba Y., Yamaguchi K., Miyazaki M., Tsubota K., Takamizawa T., and Moore B.K. Effect of air-drying time of single-step self-application self-etch adhesives on dentin bond strength. Operative Dentistry 32 (2006) 233-239
    • (2006) Operative Dentistry , vol.32 , pp. 233-239
    • Chiba, Y.1    Yamaguchi, K.2    Miyazaki, M.3    Tsubota, K.4    Takamizawa, T.5    Moore, B.K.6
  • 21
    • 33847128379 scopus 로고    scopus 로고
    • Technique sensitivity associated with air-drying of HEMA-free, single-bottle, one-step self-etch adhesives
    • Hiraishi H., Breschi L., Prati C., Ferrari M., Tagami J., and King N.M. Technique sensitivity associated with air-drying of HEMA-free, single-bottle, one-step self-etch adhesives. Dental Materials 23 (2007) 498-505
    • (2007) Dental Materials , vol.23 , pp. 498-505
    • Hiraishi, H.1    Breschi, L.2    Prati, C.3    Ferrari, M.4    Tagami, J.5    King, N.M.6
  • 22
    • 0037640986 scopus 로고    scopus 로고
    • How can nanoleakage occur in self-etching adhesive systems that demineralize and infiltrate simultaneously?
    • Tay F.R., King N.M., Chan K., and Pashley D.H. How can nanoleakage occur in self-etching adhesive systems that demineralize and infiltrate simultaneously?. Journal of Adhesive Dentistry 4 (2002) 255-269
    • (2002) Journal of Adhesive Dentistry , vol.4 , pp. 255-269
    • Tay, F.R.1    King, N.M.2    Chan, K.3    Pashley, D.H.4
  • 23
    • 0029259111 scopus 로고
    • Some effects of water on dentin bonding
    • Jacobsen T., and Söderholm K.J. Some effects of water on dentin bonding. Dental Materials 11 (1995) 132-136
    • (1995) Dental Materials , vol.11 , pp. 132-136
    • Jacobsen, T.1    Söderholm, K.J.2
  • 24
    • 0347999111 scopus 로고
    • Adhesive properties of Liner Bond II (KB-110) system Part 1. Relationship between marginal seal and tensile bond strength
    • Kubo S., Yokota H., Watanabe T., Ohsawa M., and Matsumoto H. Adhesive properties of Liner Bond II (KB-110) system Part 1. Relationship between marginal seal and tensile bond strength. Japanese Journal of Conservative Dentistry 37 (1994) 1216-1223
    • (1994) Japanese Journal of Conservative Dentistry , vol.37 , pp. 1216-1223
    • Kubo, S.1    Yokota, H.2    Watanabe, T.3    Ohsawa, M.4    Matsumoto, H.5
  • 26
    • 20144381458 scopus 로고    scopus 로고
    • The clinical performance of one- and two-step self-etching adhesive systems at one year
    • Türkün L.S. The clinical performance of one- and two-step self-etching adhesive systems at one year. Journal of American Dental Association 136 (2005) 656-664
    • (2005) Journal of American Dental Association , vol.136 , pp. 656-664
    • Türkün, L.S.1
  • 27
    • 0033191255 scopus 로고    scopus 로고
    • Tensile bond strength to and SEM evaluation of ground and intact enamel surfaces
    • Kanemura N., Sano H., and Tagami J. Tensile bond strength to and SEM evaluation of ground and intact enamel surfaces. Journal of Dentistry 27 (1999) 523-530
    • (1999) Journal of Dentistry , vol.27 , pp. 523-530
    • Kanemura, N.1    Sano, H.2    Tagami, J.3
  • 29
    • 22944473956 scopus 로고    scopus 로고
    • Enamel Bond strengths of pairs of adhesives from the same manufacturer
    • Perdigão J., Gomes G., Duarte Jr. S., and Lopes M.M. Enamel Bond strengths of pairs of adhesives from the same manufacturer. Operative Dentistry 30 (2005) 492-499
    • (2005) Operative Dentistry , vol.30 , pp. 492-499
    • Perdigão, J.1    Gomes, G.2    Duarte Jr., S.3    Lopes, M.M.4
  • 30
    • 1942504152 scopus 로고    scopus 로고
    • Shear bond stability of current adhesive systems to enamel
    • Wang H., Shimada Y., and Tagami J. Shear bond stability of current adhesive systems to enamel. Operative Dentistry 29 (2004) 168-175
    • (2004) Operative Dentistry , vol.29 , pp. 168-175
    • Wang, H.1    Shimada, Y.2    Tagami, J.3
  • 31
    • 16344385103 scopus 로고    scopus 로고
    • Self-etch vs. etch-and-rinse adhesives: effect of thermo-mechanical fatigue loading on marginal quality of bonded resin composite restorations
    • Frankenberger R., and Tay F.R. Self-etch vs. etch-and-rinse adhesives: effect of thermo-mechanical fatigue loading on marginal quality of bonded resin composite restorations. Dental Materials 21 (2005) 397-412
    • (2005) Dental Materials , vol.21 , pp. 397-412
    • Frankenberger, R.1    Tay, F.R.2
  • 32
    • 37449017025 scopus 로고    scopus 로고
    • Bonding durability of HEMA-free and HEMA-containing one-step adhesives to dentine surrounded by bonded enamel
    • Torkabadi S., Nakajima M., Ikeda M., Foxton R.M., and Tagami J. Bonding durability of HEMA-free and HEMA-containing one-step adhesives to dentine surrounded by bonded enamel. Journal of Dentistry 36 (2008) 80-86
    • (2008) Journal of Dentistry , vol.36 , pp. 80-86
    • Torkabadi, S.1    Nakajima, M.2    Ikeda, M.3    Foxton, R.M.4    Tagami, J.5
  • 33
    • 0030179952 scopus 로고    scopus 로고
    • A survey of failure modes in composite resin restorations
    • Browning W.D., and Denison W.D. A survey of failure modes in composite resin restorations. Operative Dentistry 21 (1996) 160-166
    • (1996) Operative Dentistry , vol.21 , pp. 160-166
    • Browning, W.D.1    Denison, W.D.2
  • 35
    • 0034156886 scopus 로고    scopus 로고
    • Secondary varies: a literature review with case reports
    • Mjör I.A., and Toffenetti F. Secondary varies: a literature review with case reports. Quintessence International 31 (2000) 165-179
    • (2000) Quintessence International , vol.31 , pp. 165-179
    • Mjör, I.A.1    Toffenetti, F.2
  • 39
    • 33846663556 scopus 로고    scopus 로고
    • Effect of single step adhesives on the marginal permeability of Class V rein composites
    • Owens B.M., and Johnson W.W. Effect of single step adhesives on the marginal permeability of Class V rein composites. Operative Dentistry 31 (2007) 67-72
    • (2007) Operative Dentistry , vol.31 , pp. 67-72
    • Owens, B.M.1    Johnson, W.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.