메뉴 건너뛰기




Volumn 50, Issue 1, 2009, Pages 32-36

Characterization of the magic angle effect in the equine deep digital flexor tendon using a low-field magnetic resonance system

Author keywords

Artifact; Deep digital flexor tendon; Equine; Magic angle; MR

Indexed keywords

ANIMAL; ANIMAL DISEASE; ANIMAL LAMENESS; ARTICLE; ARTIFACT; CADAVER; DIFFERENTIAL DIAGNOSIS; HISTOLOGY; HORSE; HORSE DISEASE; LIGAMENT; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; TENDON; TENDON INJURY;

EID: 58049140762     PISSN: 10588183     EISSN: 17408261     Source Type: Journal    
DOI: 10.1111/j.1740-8261.2008.01486.x     Document Type: Article
Times cited : (20)

References (7)
  • 1
    • 33847727926 scopus 로고    scopus 로고
    • Asymmetric signal intensity in normal collateral ligaments of the distal interphalangeal joint in horses with a low-field MRI system due to the magic angle effect
    • Spriet M, Mai W, McKnight A. Asymmetric signal intensity in normal collateral ligaments of the distal interphalangeal joint in horses with a low-field MRI system due to the magic angle effect. Vet Radiol Ultrasound 2007 48 : 95 100.
    • (2007) Vet Radiol Ultrasound , vol.48 , pp. 95-100
    • Spriet, M.1    Mai, W.2    McKnight, A.3
  • 2
    • 0027200370 scopus 로고
    • The "magic angle" effect: Background physics and clinical relevance
    • Erickson SJ, Prost RW, Timins ME. The "magic angle" effect: background physics and clinical relevance. Radiology 1993 188 : 23 25.
    • (1993) Radiology , vol.188 , pp. 23-25
    • Erickson, S.J.1    Prost, R.W.2    Timins, M.E.3
  • 3
    • 0026010198 scopus 로고
    • Effect of tendon orientation on MR imaging signal intensity: A manifestation of the "magic angle" phenomenon
    • Erickson SJ, Cox IH, Hyde JS, et al. Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "magic angle" phenomenon. Radiology 1991 181 : 389 392.
    • (1991) Radiology , vol.181 , pp. 389-392
    • Erickson, S.J.1    Cox, I.H.2    Hyde, J.S.3
  • 4
    • 33846822071 scopus 로고    scopus 로고
    • The magic angle effect: A source of artifact, determinant of image contrast, and technique for imaging
    • Bydder M, Rahal A, Fullerton GD, et al. The magic angle effect: a source of artifact, determinant of image contrast, and technique for imaging. J Magn Reson Imaging 2007 25 : 290 300.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 290-300
    • Bydder, M.1    Rahal, A.2    Fullerton, G.D.3
  • 5
    • 9044245303 scopus 로고    scopus 로고
    • The magic angle effect in musculoskeletal MR imaging
    • Hayes CW, Parellada JA. The magic angle effect in musculoskeletal MR imaging. Top Magn Reson Imaging 1996 8 : 51 56.
    • (1996) Top Magn Reson Imaging , vol.8 , pp. 51-56
    • Hayes, C.W.1    Parellada, J.A.2
  • 6
    • 0031975450 scopus 로고    scopus 로고
    • The magic angle phenomenon in tendons: Effect of varying the MR echo time
    • Peh WC, Chan JH. The magic angle phenomenon in tendons: effect of varying the MR echo time. Br J Radiol 1998 71 : 31 36.
    • (1998) Br J Radiol , vol.71 , pp. 31-36
    • Peh, W.C.1    Chan, J.H.2
  • 7
    • 0036731250 scopus 로고    scopus 로고
    • Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs - The magic angle effect
    • Busoni V, Snaps F. Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs - the magic angle effect. Vet Radiol Ultrasound 2002 43 : 428 430.
    • (2002) Vet Radiol Ultrasound , vol.43 , pp. 428-430
    • Busoni, V.1    Snaps, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.