-
1
-
-
0001158810
-
Nuclear magnetic resonance study of collagen hydration
-
Berendsen HJ. Nuclear magnetic resonance study of collagen hydration. J Chem Physics 1962;36:3297-305.
-
(1962)
J Chem Physics
, vol.36
, pp. 3297-3305
-
-
Berendsen, H.J.1
-
2
-
-
0021860864
-
Orientation of tendons in the magnetic field and its effect on T2 relaxation times
-
Fullerton GD, Cameron IL, Ord VA. Orientation of tendons in the magnetic field and its effect on T2 relaxation times. Radiology 1985;155:433-5.
-
(1985)
Radiology
, vol.155
, pp. 433-435
-
-
Fullerton, G.D.1
Cameron, I.L.2
Ord, V.A.3
-
3
-
-
0026010198
-
Effect of tendon orientation on MR imaging signal intensity: A manifestation of the "magic angle" phenomenon
-
Erickson SJ, Cox IH, Hyde JS, Carrera GF, Strandt JA, Estkowski LD. Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "magic angle" phenomenon. Radiology 1991;181:389-92.
-
(1991)
Radiology
, vol.181
, pp. 389-392
-
-
Erickson, S.J.1
Cox, I.H.2
Hyde, J.S.3
Carrera, G.F.4
Strandt, J.A.5
Estkowski, L.D.6
-
4
-
-
0027200370
-
The "magic angle" effect: Background physics and clinical relevance
-
Erickson SJ, Prost RW, Timins ME. The "magic angle" effect: background physics and clinical relevance. Radiology 1993;188: 23-5.
-
(1993)
Radiology
, vol.188
, pp. 23-25
-
-
Erickson, S.J.1
Prost, R.W.2
Timins, M.E.3
-
5
-
-
0026320315
-
Alterations in the supraspinatus tendon at MR imaging: Correlation with histopathologic findings in cadavers
-
Kjellin I, Ho CP, Cervilla V, et al. Alterations in the supraspinatus tendon at MR imaging: correlation with histopathologic findings in cadavers. Radiology 1991;181:837-41.
-
(1991)
Radiology
, vol.181
, pp. 837-841
-
-
Kjellin, I.1
Ho, C.P.2
Cervilla, V.3
-
6
-
-
0024403839
-
Rotator cuff tears: Diagnostic performance of MR imaging
-
Zlatkin MB, Iannotti JP, Roberts MC, et al. Rotator cuff tears: diagnostic performance of MR imaging. Radiology 1989;172: 223-229.
-
(1989)
Radiology
, vol.172
, pp. 223-229
-
-
Zlatkin, M.B.1
Iannotti, J.P.2
Roberts, M.C.3
-
7
-
-
0028340881
-
"Magic angle" phenomenon: A cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee
-
Peterfy CG, Janzen DL, Tirman PF, van Dijke CF, Pollack M, Genant HK. "Magic angle" phenomenon: a cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee. AJR 1994;163:149-54.
-
(1994)
AJR
, vol.163
, pp. 149-154
-
-
Peterfy, C.G.1
Janzen, D.L.2
Tirman, P.F.3
Van Dijke, C.F.4
Pollack, M.5
Genant, H.K.6
-
8
-
-
0027177336
-
Effects of collagen orientation on MR imaging characteristics of bovine articular cartilage
-
Rubenstein JD, Kim JK, Morava-Protzner I, Stanchev PL, Henkelman RM. Effects of collagen orientation on MR imaging characteristics of bovine articular cartilage. Radiology 1993;188:219-26.
-
(1993)
Radiology
, vol.188
, pp. 219-226
-
-
Rubenstein, J.D.1
Kim, J.K.2
Morava-Protzner, I.3
Stanchev, P.L.4
Henkelman, R.M.5
|