메뉴 건너뛰기




Volumn 48, Issue 2, 2007, Pages 95-100

Asymmetric signal intensity in normal collateral ligaments of the distal interphalangeal joint in horses with a low-field MRI system due to the magic angle effect

Author keywords

Artifact; Collateral ligaments of the distal interphalangeal joint; Equine; Foot; Magic angle effect; Magnetic resonance imaging

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; HISTOLOGY; HORSE; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; TOE JOINT;

EID: 33847727926     PISSN: 10588183     EISSN: 17408261     Source Type: Journal    
DOI: 10.1111/j.1740-8261.2007.00211.x     Document Type: Article
Times cited : (44)

References (20)
  • 1
    • 1542604362 scopus 로고    scopus 로고
    • Lameness in 46 horses associated with deep digital flexor tendonitis in the digit: Diagnosis confirmed with magnetic resonance imaging
    • Dyson S, Murray R, Schramme M, et al. Lameness in 46 horses associated with deep digital flexor tendonitis in the digit: diagnosis confirmed with magnetic resonance imaging. Equine Vet J 2003;35:681-690.
    • (2003) Equine Vet J , vol.35 , pp. 681-690
    • Dyson, S.1    Murray, R.2    Schramme, M.3
  • 2
    • 0037267730 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the equine foot: 15 horses
    • Dyson S, Murray R, Schramme M, et al. Magnetic resonance imaging of the equine foot: 15 horses. Equine Vet J 2003;35:18-26.
    • (2003) Equine Vet J , vol.35 , pp. 18-26
    • Dyson, S.1    Murray, R.2    Schramme, M.3
  • 3
    • 14844283155 scopus 로고    scopus 로고
    • Lameness associated with foot pain: Results of magnetic resonance imaging in 199 horses (January 2001- December 2003) and response to treatment
    • Dyson SJ, Murray R, SchrammeMC. Lameness associated with foot pain: results of magnetic resonance imaging in 199 horses (January 2001- December 2003) and response to treatment. Equine Vet J 2005;37:113-121.
    • (2005) Equine Vet J , vol.37 , pp. 113-121
    • Dyson, S.J.1    Murray, R.2    SchrammeMC3
  • 4
    • 26244462105 scopus 로고    scopus 로고
    • Magnetic resonance imaging findings in the equine deep digital flexor tendon and distal sesamoid bone in advanced navicular disease-an ex vivo study
    • Busoni V, Heimann M, Trenteseaux J, et al. Magnetic resonance imaging findings in the equine deep digital flexor tendon and distal sesamoid bone in advanced navicular disease-an ex vivo study. Vet Radiol Ultrasound 2005;46:279-286.
    • (2005) Vet Radiol Ultrasound , vol.46 , pp. 279-286
    • Busoni, V.1    Heimann, M.2    Trenteseaux, J.3
  • 5
    • 14944351026 scopus 로고    scopus 로고
    • Injury of the collateral ligaments of the distal interphalangeal joint diagnosed by magnetic resonance
    • Zubrod CJ, Farnsworth KD, Tucker RL, et al. Injury of the collateral ligaments of the distal interphalangeal joint diagnosed by magnetic resonance. Vet Radiol Ultrasound 2005;46:11-16.
    • (2005) Vet Radiol Ultrasound , vol.46 , pp. 11-16
    • Zubrod, C.J.1    Farnsworth, K.D.2    Tucker, R.L.3
  • 6
    • 2542586300 scopus 로고    scopus 로고
    • Collateral desmitis of the distal interphalangeal joint in 18 horses (2001-2002)
    • Dyson SJ, Murray R, Schramme M, et al. Collateral desmitis of the distal interphalangeal joint in 18 horses (2001-2002). Equine Vet J 2004; 36:160-166.
    • (2004) Equine Vet J , vol.36 , pp. 160-166
    • Dyson, S.J.1    Murray, R.2    Schramme, M.3
  • 7
    • 9044245303 scopus 로고    scopus 로고
    • The magic angle effect in musculoskeletal MR imaging
    • Hayes CW, Parellada JA. The magic angle effect in musculoskeletal MR imaging. Top Magn Reson Imaging 1996;8:51-56.
    • (1996) Top Magn Reson Imaging , vol.8 , pp. 51-56
    • Hayes, C.W.1    Parellada, J.A.2
  • 8
    • 0026010198 scopus 로고
    • Effect of tendon orientation on MR imaging signal intensity: A manifestation of the "magic angle" phenomenon
    • Erickson SJ, Cox IH, Hyde JS, et al. Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "magic angle" phenomenon. Radiology 1991;181:389-392.
    • (1991) Radiology , vol.181 , pp. 389-392
    • Erickson, S.J.1    Cox, I.H.2    Hyde, J.S.3
  • 9
    • 0027200370 scopus 로고
    • The "magic angle" effect: Background physics and clinical relevance
    • Erickson SJ, Prost RW, Timins ME. The "magic angle" effect: background physics and clinical relevance. Radiology 1993;188:23-25.
    • (1993) Radiology , vol.188 , pp. 23-25
    • Erickson, S.J.1    Prost, R.W.2    Timins, M.E.3
  • 10
    • 0036731250 scopus 로고    scopus 로고
    • Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs-the magic angle effect
    • Busoni V, Snaps F. Effect of deep digital flexor tendon orientation on magnetic resonance imaging signal intensity in isolated equine limbs-the magic angle effect. Vet Radiol Ultrasound 2002;43:428-430.
    • (2002) Vet Radiol Ultrasound , vol.43 , pp. 428-430
    • Busoni, V.1    Snaps, F.2
  • 11
    • 0021860864 scopus 로고
    • Orientation of tendons in the magnetic field and its effect on T2 relaxation times
    • Fullerton GD, Cameron IL, Ord VA. Orientation of tendons in the magnetic field and its effect on T2 relaxation times. Radiology 1985;155: 433-435.
    • (1985) Radiology , vol.155 , pp. 433-435
    • Fullerton, G.D.1    Cameron, I.L.2    Ord, V.A.3
  • 12
    • 3042768127 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the palmar aspect of the equine podotrochlear apparatus: Normal appearance
    • Busoni V, Snaps F, Trenteseaux J, et al. Magnetic resonance imaging of the palmar aspect of the equine podotrochlear apparatus: normal appearance. Vet Radiol Ultrasound 2004;45:198-204.
    • (2004) Vet Radiol Ultrasound , vol.45 , pp. 198-204
    • Busoni, V.1    Snaps, F.2    Trenteseaux, J.3
  • 13
    • 33750596439 scopus 로고    scopus 로고
    • The magic-angle effect of the supraspinatus tendon
    • Madden ME. The magic-angle effect of the supraspinatus tendon. Radiol Technol 2006;77:357-365.
    • (2006) Radiol Technol , vol.77 , pp. 357-365
    • Madden, M.E.1
  • 14
    • 0029037689 scopus 로고
    • Increased signal in the normal supraspinatus tendon on MR imaging: Diagnostic pitfall caused by the magic-angle effect
    • Timins ME, Erickson SJ, Estkowski LD, et al. Increased signal in the normal supraspinatus tendon on MR imaging: diagnostic pitfall caused by the magic-angle effect. Am J Roentgenol 1995;165:109-114.
    • (1995) Am J Roentgenol , vol.165 , pp. 109-114
    • Timins, M.E.1    Erickson, S.J.2    Estkowski, L.D.3
  • 15
    • 0032617022 scopus 로고    scopus 로고
    • Evaluation of magnetic resonance imaging techniques in the equine digit
    • Kleiter M, Kneissl S, Stanek C, et al. Evaluation of magnetic resonance imaging techniques in the equine digit. Vet Radiol Ultrasound 1999;40:15-22.
    • (1999) Vet Radiol Ultrasound , vol.40 , pp. 15-22
    • Kleiter, M.1    Kneissl, S.2    Stanek, C.3
  • 16
    • 0031975450 scopus 로고    scopus 로고
    • The magic angle phenomenon in tendons: Effect of varying the MR echo time
    • Peh WC, Chan JH. The magic angle phenomenon in tendons: effect of varying the MR echo time. Br J Radiol 1998;71:31-36.
    • (1998) Br J Radiol , vol.71 , pp. 31-36
    • Peh, W.C.1    Chan, J.H.2
  • 17
    • 0141992810 scopus 로고    scopus 로고
    • Manifestation of magic angle phenomenon: Comparative study on effects of varying echo time and tendon orientation among various MR sequences
    • Li T, Mirowitz SA. Manifestation of magic angle phenomenon: comparative study on effects of varying echo time and tendon orientation among various MR sequences. Magn Reson Imaging 2003;21: 741-744.
    • (2003) Magn Reson Imaging , vol.21 , pp. 741-744
    • Li, T.1    Mirowitz, S.A.2
  • 18
    • 0033747436 scopus 로고    scopus 로고
    • The influence of flip angle on the magic angle effect
    • Zurlo JV, Blacksin MF, Karimi S. The influence of flip angle on the magic angle effect. Skeletal Radiol 2000;29:593-596.
    • (2000) Skeletal Radiol , vol.29 , pp. 593-596
    • Zurlo, J.V.1    Blacksin, M.F.2    Karimi, S.3
  • 19
    • 32644478607 scopus 로고    scopus 로고
    • MRI "magic angle" imaging of finger tendons
    • Br
    • Lambe G, Coutts G, McArthur P, et al.MRI "magic angle" imaging of finger tendons. J Hand Surg [Br] 2006;31:149-153.
    • (2006) J Hand Surg , vol.31 , pp. 149-153
    • Lambe, G.1    Coutts, G.2    McArthur, P.3
  • 20
    • 0037730182 scopus 로고    scopus 로고
    • Magic angle imaging of the achilles tendon in patients with chronic tendonopathy
    • Oatridge A, Herlihy A, Thomas RW, et al. Magic angle imaging of the achilles tendon in patients with chronic tendonopathy. Clin Radiol 2003;58:384-388.
    • (2003) Clin Radiol , vol.58 , pp. 384-388
    • Oatridge, A.1    Herlihy, A.2    Thomas, R.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.