메뉴 건너뛰기




Volumn 18, Issue 1, 2009, Pages 22-28

Removal of oral secretion prior to position change can reduce the incidence of ventilator-associated pneumonia for adult ICU patients: A clinical controlled trial study

Author keywords

Aspiration secretion; Intensive care unit; Nurses; Nursing; Ventilator associated pneumonia

Indexed keywords

AGED; ARTICLE; ARTIFICIAL VENTILATION; BACTERIAL PNEUMONIA; CASE CONTROL STUDY; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CROSS INFECTION; FEMALE; HUMAN; INCIDENCE; INTENSIVE CARE UNIT; MALE; MIDDLE AGED; MUCUS; RISK REDUCTION; SUCTION; TAIWAN;

EID: 57649236211     PISSN: 09621067     EISSN: 13652702     Source Type: Journal    
DOI: 10.1111/j.1365-2702.2007.02193.x     Document Type: Article
Times cited : (34)

References (18)
  • 2
    • 70350001244 scopus 로고    scopus 로고
    • 2002 CDC guidelines and ATS guidelines
    • American Thoracic Society (
    • American Thoracic Society (2005) 2002 CDC guidelines and ATS guidelines. American Journal of Respiratory & Critical Care Medicine 171, 388 416.
    • (2005) American Journal of Respiratory & Critical Care Medicine , vol.171 , pp. 388-416
  • 5
    • 0032507210 scopus 로고    scopus 로고
    • Influence of airway management on ventilator-associated pneumonia: Evidence from randomized trials
    • Cook D, Jonghe B, Brochard L Brun-Buisson C (1998) Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 279, 781 787.
    • (1998) JAMA , vol.279 , pp. 781-787
    • Cook, D.1    Jonghe, B.2    Brochard, L.3    Brun-Buisson, C.4
  • 6
    • 0021683471 scopus 로고
    • Contaminated medication nebulizers in mechanical ventilator circuits. Source of bacterial aerosols
    • Craven D, Linchtenberg D, Goularte T, Make B McCAbe WR (1984) Contaminated medication nebulizers in mechanical ventilator circuits. Source of bacterial aerosols. American Journal of Medicine 77, 834 838.
    • (1984) American Journal of Medicine , vol.77 , pp. 834-838
    • Craven, D.1    Linchtenberg, D.2    Goularte, T.3    Make, B.4    McCabe, W.R.5
  • 8
    • 27644553020 scopus 로고    scopus 로고
    • A review of the possible role of oral and dental colonization on the occurrence of health care-associated pneumonia: Underappreciated risk and a call for intervention
    • Garcia B (2005) A review of the possible role of oral and dental colonization on the occurrence of health care-associated pneumonia: underappreciated risk and a call for intervention. American Journal of Infection Control 33, 527 541.
    • (2005) American Journal of Infection Control , vol.33 , pp. 527-541
    • Garcia, B.1
  • 9
    • 0028968062 scopus 로고
    • The effects of circuit and humidifier type on contamination potential during mechanical ventilation: A laboratory study
    • Gilmour L, Boyle M, Streifel A McComb R (1995) The effects of circuit and humidifier type on contamination potential during mechanical ventilation: A laboratory study. American Journal of Infection Control 23, 65 72.
    • (1995) American Journal of Infection Control , vol.23 , pp. 65-72
    • Gilmour, L.1    Boyle, M.2    Streifel, A.3    McComb, R.4
  • 10
    • 33846680633 scopus 로고    scopus 로고
    • Patient positioning and ventilator-associated pneumonia
    • Hess DR (2005) Patient positioning and ventilator-associated pneumonia. Respiratory Care 50, 892 898.
    • (2005) Respiratory Care , vol.50 , pp. 892-898
    • Hess, D.R.1
  • 11
    • 0033602066 scopus 로고    scopus 로고
    • The prevention of ventilator-associated pneumonia
    • Kollef MH (1999) The prevention of ventilator-associated pneumonia. New England Journal of Medicine 340, 627 634.
    • (1999) New England Journal of Medicine , vol.340 , pp. 627-634
    • Kollef, M.H.1
  • 12
    • 30344451643 scopus 로고    scopus 로고
    • Epidemiology and outcomes of health-care-associated pneumonia: Results from a large US database of culture-positive pneumonia
    • Kollef MH, Shorr A, Tabak YP, Gupta V, Liu LZ Johnnes RS (2005) Epidemiology and outcomes of health-care-associated pneumonia: results from a large US database of culture-positive pneumonia. Chest 128, 3854 3862.
    • (2005) Chest , vol.128 , pp. 3854-3862
    • Kollef, M.H.1    Shorr, A.2    Tabak, Y.P.3    Gupta, V.4    Liu, L.Z.5    Johnnes, R.S.6
  • 13
    • 7644231771 scopus 로고    scopus 로고
    • Oral health and care in the intensive care unit: State of the science
    • Munro CL Grap MJ (2004) Oral health and care in the intensive care unit: state of the science. American Journal of Critical Care 13, 25 33.
    • (2004) American Journal of Critical Care , vol.13 , pp. 25-33
    • Munro, C.L.1    Grap, M.J.2
  • 14
    • 0036177303 scopus 로고    scopus 로고
    • Nosocomial infections in a neonatal intensive care unit: Incidence and risk factors
    • Nagata E, Brito AS Mastsuo T (2002) Nosocomial infections in a neonatal intensive care unit: Incidence and risk factors. American Journal of Infection Control 30, 26 30.
    • (2002) American Journal of Infection Control , vol.30 , pp. 26-30
    • Nagata, E.1    Brito, A.S.2    Mastsuo, T.3
  • 15
    • 0004296312 scopus 로고
    • National Committee for Clinical Laboratory Standards. (. National Committee for Clinical Laboratory Standards, Villanova.
    • National Committee for Clinical Laboratory Standards. (1993) Performance Standards for Antimicrobial Disk Susceptibility Tests. NCCLS document M2-A5. National Committee for Clinical Laboratory Standards, Villanova.
    • (1993) Performance Standards for Antimicrobial Disk Susceptibility Tests. NCCLS Document M2-A5.
  • 16
    • 0036202886 scopus 로고    scopus 로고
    • A randomized clinical trial of intermittent subglottic secretion drainage in patients receiving mechanical ventilation
    • Smulders K, Hoeven H, Weers-Pothoff I Vandenbroucke-Grauls C (2002) A randomized clinical trial of intermittent subglottic secretion drainage in patients receiving mechanical ventilation. Chest 121, 858 862.
    • (2002) Chest , vol.121 , pp. 858-862
    • Smulders, K.1    Hoeven, H.2    Weers-Pothoff, I.3    Vandenbroucke-Grauls, C.4
  • 17
    • 0030016983 scopus 로고    scopus 로고
    • Incidence of Ventilator-associated pneumonia with14-day circuit change in a subacute environment
    • Thompson RE (1996) Incidence of Ventilator-associated pneumonia with14-day circuit change in a subacute environment. Respiratory Care 41, 601 606.
    • (1996) Respiratory Care , vol.41 , pp. 601-606
    • Thompson, R.E.1
  • 18
    • 0026606379 scopus 로고
    • Pulmonary aspiration of gastric contents in patients receiving mechanical ventilation: The effect of body position
    • Torres A, Serra-Batlles J, Ros E, Piera C, Puig D Bellacasa J (1992) Pulmonary aspiration of gastric contents in patients receiving mechanical ventilation: the effect of body position. Annals of Internal Medicine 116, 540 543.
    • (1992) Annals of Internal Medicine , vol.116 , pp. 540-543
    • Torres, A.1    Serra-Batlles, J.2    Ros, E.3    Piera, C.4    Puig, D.5    Bellacasa, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.