메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2126-2129

Impact of realignment on spinal functional MRI time series

Author keywords

Cardiac noise; fMRI; Functional MRI; General linear model; GLM; Realignment; Spinal cord

Indexed keywords

CARDIOLOGY; DATA ACQUISITION; ESTIMATION; TIME SERIES ANALYSIS;

EID: 57649215572     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2007.4352742     Document Type: Conference Paper
Times cited : (10)

References (18)
  • 2
    • 0031910991 scopus 로고    scopus 로고
    • Automated image registration: I. General methods and intrasubject, intramodality validation
    • Jan-Feb
    • R. P. Woods, S. T. Grafton, C. J. Holmes, S. R. Cherry, and J. C. Mazziotta, "Automated image registration: I. General methods and intrasubject, intramodality validation," J Comput Assist Tomogr, vol. 22, pp. 139-52, Jan-Feb 1998.
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 139-152
    • Woods, R.P.1    Grafton, S.T.2    Holmes, C.J.3    Cherry, S.R.4    Mazziotta, J.C.5
  • 3
    • 0034878761 scopus 로고    scopus 로고
    • Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
    • L. Freire and Mangin, "Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion," NeuroImage, vol. 14, pp. 709-722, 2001.
    • (2001) NeuroImage , vol.14 , pp. 709-722
    • Freire, L.1    Mangin2
  • 5
    • 11844282803 scopus 로고    scopus 로고
    • An information-theoretic criterion for intrasubject alignment of FMRI time series: Motion corrected independent component analysis
    • R. Liao, J. L. Krolik, and M. J. McKeown, "An information-theoretic criterion for intrasubject alignment of FMRI time series: motion corrected independent component analysis," IEEE Trans Med Imaging, vol. 24, pp. 29-44, 2005.
    • (2005) IEEE Trans Med Imaging , vol.24 , pp. 29-44
    • Liao, R.1    Krolik, J.L.2    McKeown, M.J.3
  • 7
    • 33645046092 scopus 로고    scopus 로고
    • The enigma of Mayer waves: Facts and models
    • C. Julien, "The enigma of Mayer waves: Facts and models," Cardiovascular Research, vol. 70, pp. 12-21, 2006.
    • (2006) Cardiovascular Research , vol.70 , pp. 12-21
    • Julien, C.1
  • 8
  • 11
    • 29244477177 scopus 로고    scopus 로고
    • Non-white noise in fMRI: Does modelling have an impact?
    • T. Lund, K. Madsen, K. Sidaros, W.-L. Luo, and T. Nichols, "Non-white noise in fMRI: Does modelling have an impact?," NeuroImage, vol. 29, pp. 54-66, 2006.
    • (2006) NeuroImage , vol.29 , pp. 54-66
    • Lund, T.1    Madsen, K.2    Sidaros, K.3    Luo, W.-L.4    Nichols, T.5
  • 12
    • 0032777187 scopus 로고    scopus 로고
    • Localization of cardiacinduced signal change in fMRI
    • Apr
    • M. S. Dagli, J. E. Ingeholm, and J. V. Haxby, "Localization of cardiacinduced signal change in fMRI," Neuroimage, vol. 9, pp. 407-15, Apr 1999.
    • (1999) Neuroimage , vol.9 , pp. 407-415
    • Dagli, M.S.1    Ingeholm, J.E.2    Haxby, J.V.3
  • 13
    • 0035088894 scopus 로고    scopus 로고
    • Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data
    • L. Frank, R. Buxton, and E. Wong, "Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data," Magnetic Resonance in Medicine, vol. 45, pp. 635-644, 2001.
    • (2001) Magnetic Resonance in Medicine , vol.45 , pp. 635-644
    • Frank, L.1    Buxton, R.2    Wong, E.3
  • 14
    • 0036430903 scopus 로고    scopus 로고
    • Noise reduction in BOLD-based fMRI using component analysis
    • C. G. Thomas, R. A. Harshman, and R. S. Menon, "Noise reduction in BOLD-based fMRI using component analysis," Neuroimage, vol. 17, pp. 1521-1537, 2002.
    • (2002) Neuroimage , vol.17 , pp. 1521-1537
    • Thomas, C.G.1    Harshman, R.A.2    Menon, R.S.3
  • 16
    • 0033251944 scopus 로고    scopus 로고
    • Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information
    • Dec
    • F. Maes, D. Vandermeulen, and P. Suetens, "Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information," Med Image Anal, vol. 3, pp. 373-86, Dec 1999.
    • (1999) Med Image Anal , vol.3 , pp. 373-386
    • Maes, F.1    Vandermeulen, D.2    Suetens, P.3
  • 17
    • 0034852407 scopus 로고    scopus 로고
    • Comparison of functional MRI image realignment tools using a computer-generated phantom
    • V. L. Morgan, D. R. Pickens, S. L. Hartmann, and R. R. Price, "Comparison of functional MRI image realignment tools using a computer-generated phantom," Magn Reson Med, vol. 46, pp. 510-514, 2001.
    • (2001) Magn Reson Med , vol.46 , pp. 510-514
    • Morgan, V.L.1    Pickens, D.R.2    Hartmann, S.L.3    Price, R.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.