메뉴 건너뛰기




Volumn 22, Issue 1, 1998, Pages 139-152

Automated image registration: I. General methods and intrasubject, intramodality validation

Author keywords

Brain mapping; Emission computed tomography; Image registration; Magnetic resonance imaging

Indexed keywords

ALGORITHM; ARTICLE; AUTOANALYSIS; BRAIN MAPPING; IMAGE ANALYSIS; MODEL; NEURORADIOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL;

EID: 0031910991     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004728-199801000-00027     Document Type: Article
Times cited : (1606)

References (22)
  • 1
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods RP, Cherry SR, Mazziotta JC. Rapid automated algorithm for aligning and reslicing PET images. J Comput Assist Tomogr 1992;16:620-33.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziotta, J.C.3
  • 2
    • 0029197930 scopus 로고
    • Motion detection and correction in functional MR imaging
    • Jiang AP, Kennedy DN, Baker JR, et al. Motion detection and correction in functional MR imaging. Hum Brain Map 1995;3: 224-35.
    • (1995) Hum Brain Map , vol.3 , pp. 224-235
    • Jiang, A.P.1    Kennedy, D.N.2    Baker, J.R.3
  • 5
    • 18844474299 scopus 로고    scopus 로고
    • Comparison and evaluation of retrospective intermodality image registration techniques
    • West J, Fitzpatrick JM, Wang MY, et al. Comparison and evaluation of retrospective intermodality image registration techniques. J Comput Assist Tomogr 1997;21:554-66.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 554-566
    • West, J.1    Fitzpatrick, J.M.2    Wang, M.Y.3
  • 9
    • 0029392117 scopus 로고
    • Convolution-based interpolation for fast, high-quality rotation of images
    • Unser M, Thevenaz P, Yaroslavsky L. Convolution-based interpolation for fast, high-quality rotation of images. IEEE Trans Image Proc 1995;4:1371-81.
    • (1995) IEEE Trans Image Proc , vol.4 , pp. 1371-1381
    • Unser, M.1    Thevenaz, P.2    Yaroslavsky, L.3
  • 10
    • 0028548921 scopus 로고
    • Avoidance of additional aliasing in multipass image rotations
    • Fraser D, Schowengerdt RA. Avoidance of additional aliasing in multipass image rotations. IEEE Trans Image Proc 1994;3:721-35.
    • (1994) IEEE Trans Image Proc , vol.3 , pp. 721-735
    • Fraser, D.1    Schowengerdt, R.A.2
  • 14
    • 0002628693 scopus 로고    scopus 로고
    • Difference image versus ratio image error function forms in PET-PET realignment
    • San Diego: Academic Press
    • Snyder AZ. Difference image versus ratio image error function forms in PET-PET realignment. In: Quantification of brain function using PET. San Diego: Academic Press, 1996:131-7.
    • (1996) Quantification of Brain Function Using PET , pp. 131-137
    • Snyder, A.Z.1
  • 18
    • 0026463748 scopus 로고
    • Brain parenchyma motion: Measurement with cine echo-planar MR imaging
    • Poncelet BP, Wedeen VJ, Weisskoff RM, Cohen MS. Brain parenchyma motion: measurement with cine echo-planar MR imaging. Radiology 1992;185:645-51.
    • (1992) Radiology , vol.185 , pp. 645-651
    • Poncelet, B.P.1    Wedeen, V.J.2    Weisskoff, R.M.3    Cohen, M.S.4
  • 19
    • 0026925939 scopus 로고
    • A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
    • Chang H, Fitzpatrick JM. A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE Trans Med Imag 1992;11:319-29.
    • (1992) IEEE Trans Med Imag , vol.11 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2
  • 20
    • 0029802526 scopus 로고    scopus 로고
    • Accurate registration of serial 3D MR brain images and its application to visualizing change in neurodegenerative disorders
    • Freeborough PA, Woods RP, Fox NC. Accurate registration of serial 3D MR brain images and its application to visualizing change in neurodegenerative disorders. J Comput Assist Tomogr 1996;20:1012-22.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 1012-1022
    • Freeborough, P.A.1    Woods, R.P.2    Fox, N.C.3
  • 22
    • 25344457314 scopus 로고    scopus 로고
    • Signal gradient normalization improves head motion correction in surface-coil functional magnetic resonance imaging
    • Zeffiro TA, VanMeter JW, Eden GF, Woods RP. Signal gradient normalization improves head motion correction in surface-coil functional magnetic resonance imaging. Neuroimage 1996;3:S110.
    • (1996) Neuroimage , vol.3
    • Zeffiro, T.A.1    VanMeter, J.W.2    Eden, G.F.3    Woods, R.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.