-
1
-
-
0042830398
-
New options for airway management: Intubating fibreoptic stylets
-
Liem E, Bjoraker D, Gravenstein D. New options for airway management: intubating fibreoptic stylets. Br J Anaesthesia 2003; 91:408-418.
-
(2003)
Br J Anaesthesia
, vol.91
, pp. 408-418
-
-
Liem, E.1
Bjoraker, D.2
Gravenstein, D.3
-
2
-
-
56849114397
-
-
Cooper R, Law J. Rigid and semirigid fiberoptic and video laryngoscopy and intubation. In: Hung O, Murphy M, editors. Management of the difficult and failed airway. New York: McGraw-Hill Medical; 2008. An excellent review with many color photographs and text in question and answer format.
-
Cooper R, Law J. Rigid and semirigid fiberoptic and video laryngoscopy and intubation. In: Hung O, Murphy M, editors. Management of the difficult and failed airway. New York: McGraw-Hill Medical; 2008. An excellent review with many color photographs and text in question and answer format.
-
-
-
-
3
-
-
36849064281
-
Rigid and semirigid fiberoptic intubation
-
Walls R, Murphy M, Luten R, Schneider J, editors, 2nd ed. Philadelphia: Lippincott Williams & Wilkins;
-
Murphy M, Law J. Rigid and semirigid fiberoptic intubation. In: Walls R, Murphy M, Luten R, Schneider J, editors. Manual of emergency airway management, 2nd ed. Philadelphia: Lippincott Williams & Wilkins; 2004.
-
(2004)
Manual of emergency airway management
-
-
Murphy, M.1
Law, J.2
-
4
-
-
56849115805
-
Video laryngoscopy
-
Walls R, Murphy M, Luten R, Schneider J, editors, 2nd ed. Philadelphia: Lippincott Williams & Wilkins;
-
Sakles J. Video laryngoscopy. In: Walls R, Murphy M, Luten R, Schneider J, editors. Manual of emergency airway management, 2nd ed. Philadelphia: Lippincott Williams & Wilkins; 2004.
-
(2004)
Manual of emergency airway management
-
-
Sakles, J.1
-
5
-
-
85013686318
-
Benumof's airway management
-
2nd ed, A new edition of the definitive text on airway management. An essential reading on this subject
-
Hagberg C. Benumof's airway management. 2nd ed. Philadelphia: Mosby Elsevier; 2007. A new edition of the definitive text on airway management. An essential reading on this subject.
-
(2007)
Philadelphia: Mosby Elsevier
-
-
Hagberg, C.1
-
6
-
-
43749119189
-
Optical and video laryngoscopes for emergency airway management
-
An excellent recent review of optical and video laryngoscopes has good descriptions of recently released equipment
-
Sakles J, Rodgers R, Keim S. Optical and video laryngoscopes for emergency airway management. Intern Emerg Med 2008; 3:139-143. An excellent recent review of optical and video laryngoscopes has good descriptions of recently released equipment.
-
(2008)
Intern Emerg Med
, vol.3
, pp. 139-143
-
-
Sakles, J.1
Rodgers, R.2
Keim, S.3
-
7
-
-
16344374081
-
Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients
-
Cooper R, Pacey J, Bishop M, McCluskey S. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anesth 2005; 52:191-198.
-
(2005)
Can J Anesth
, vol.52
, pp. 191-198
-
-
Cooper, R.1
Pacey, J.2
Bishop, M.3
McCluskey, S.4
-
8
-
-
33947720075
-
Airway Scope: Initial clinical experience with novice personnel [letter]
-
Hirabayashi Y. Airway Scope: initial clinical experience with novice personnel [letter]. Can J Anesth 2007; 54:160-161.
-
(2007)
Can J Anesth
, vol.54
, pp. 160-161
-
-
Hirabayashi, Y.1
-
9
-
-
44949109993
-
-
Mihai R, Blair E, Kay H, Cook T. A quantitative review and meta-analysis of performance of nonstandard laryngoscopes and rigid fibreoptic intubation aids. Anaesthesia 2008; 63:745-760. A meta-analysis of laryngoscopes other than the standard Macintosh, examining studies from the period 1990-2006.
-
Mihai R, Blair E, Kay H, Cook T. A quantitative review and meta-analysis of performance of nonstandard laryngoscopes and rigid fibreoptic intubation aids. Anaesthesia 2008; 63:745-760. A meta-analysis of laryngoscopes other than the standard Macintosh, examining studies from the period 1990-2006.
-
-
-
-
10
-
-
42249114003
-
Brief report: Tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy of patients with a simulated difficult airway
-
A randomized control study of 76 normal patients who were placed in a cervical collar prior to induction. Intubation was successful more frequently, and intubation time was shorter when using the Bonfils
-
Byhahn C, Nemetz S, Breitkreutz R, Zwissler B. Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy of patients with a simulated difficult airway. Can J Anesth 2008; 55:232-237. A randomized control study of 76 normal patients who were placed in a cervical collar prior to induction. Intubation was successful more frequently, and intubation time was shorter when using the Bonfils.
-
(2008)
Can J Anesth
, vol.55
, pp. 232-237
-
-
Byhahn, C.1
Nemetz, S.2
Breitkreutz, R.3
Zwissler, B.4
-
11
-
-
0037406762
-
Practice Guidelines for Management of the Difficult Airway: An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
-
American Society of Anesthesiologists Task Force on Management of the Difficult Airway
-
American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Practice Guidelines for Management of the Difficult Airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2003; 98:1269-1277.
-
(2003)
Anesthesiology
, vol.98
, pp. 1269-1277
-
-
-
12
-
-
3242884152
-
Difficult Airway Society guidelines for management of the unanticipated difficult intubation
-
Henderson J, Popat M, Latto I, Pearce A. Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004; 59:675-694.
-
(2004)
Anaesthesia
, vol.59
, pp. 675-694
-
-
Henderson, J.1
Popat, M.2
Latto, I.3
Pearce, A.4
-
13
-
-
10044224412
-
Tracheal intubation using the Bonfils intubation fiberscope after failed direct laryngoscopy
-
Bein B, Yan M, Tonner P, et al. Tracheal intubation using the Bonfils intubation fiberscope after failed direct laryngoscopy. Anaesthesia 2004; 59:1207-1209.
-
(2004)
Anaesthesia
, vol.59
, pp. 1207-1209
-
-
Bein, B.1
Yan, M.2
Tonner, P.3
-
14
-
-
34047101309
-
Retention of tracheal intubation skills by novice personnel: A comparison of the Airtraq and Macintosh laryngoscopes
-
A controlled study, using 20 medical students, which first demonstrates the poor retention of intubating skills without practice, and, second, that Airtraq skills are retained better
-
Maharaj C, Costello J, Higgins B, et al. Retention of tracheal intubation skills by novice personnel: a comparison of the Airtraq and Macintosh laryngoscopes. Anaesthesia 2007; 62:272-278. A controlled study, using 20 medical students, which first demonstrates the poor retention of intubating skills without practice, and, second, that Airtraq skills are retained better.
-
(2007)
Anaesthesia
, vol.62
, pp. 272-278
-
-
Maharaj, C.1
Costello, J.2
Higgins, B.3
-
15
-
-
33947248572
-
Clinical comparisons between GlideScope video laryngoscope and Trachlight in simulated cervical spine instability
-
This article concludes that the Trachlight offers a faster intubation and milder hemodynamic response than the GlideScope
-
Huang W, Huang C, Chung Y. Clinical comparisons between GlideScope video laryngoscope and Trachlight in simulated cervical spine instability. J Clin Anesth 2007; 19:110-114. This article concludes that the Trachlight offers a faster intubation and milder hemodynamic response than the GlideScope.
-
(2007)
J Clin Anesth
, vol.19
, pp. 110-114
-
-
Huang, W.1
Huang, C.2
Chung, Y.3
-
16
-
-
13544263512
-
Evaluation of ease of intubation with the GlideScope or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy
-
Lim T, Lim Y, Liu E. Evaluation of ease of intubation with the GlideScope or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy. Anaesthesia 2005; 60:180-183.
-
(2005)
Anaesthesia
, vol.60
, pp. 180-183
-
-
Lim, T.1
Lim, Y.2
Liu, E.3
-
17
-
-
11444255353
-
The GlideScope system: A clinical assessment of performance
-
Rai M, Dering A, Verghese C. The GlideScope system: a clinical assessment of performance. Anaesthesia 2005; 60:60-64.
-
(2005)
Anaesthesia
, vol.60
, pp. 60-64
-
-
Rai, M.1
Dering, A.2
Verghese, C.3
-
18
-
-
34547556776
-
Tracheal intubation by nonanaesthetist physicians using the Airway Scope
-
This article concludes the AWS may reduce the time to secure the airway and the incidence of failed tracheal intubations in novice laryngoscopists
-
Hirabayashi Y, Seo N. Tracheal intubation by nonanaesthetist physicians using the Airway Scope. Emerg Med J 2007; 24:572-573. This article concludes the AWS may reduce the time to secure the airway and the incidence of failed tracheal intubations in novice laryngoscopists.
-
(2007)
Emerg Med J
, vol.24
, pp. 572-573
-
-
Hirabayashi, Y.1
Seo, N.2
-
19
-
-
35348943433
-
Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naïve operators: A manikin study
-
This article concludes the AWS is more useful for beginners as it provides quicker and easier tracheal intubation
-
Miki T, Inagawa G, Kikuchi T, et al. Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naïve operators: a manikin study. Acta Anaesthesiol Scand 2007; 51:1378-1381. This article concludes the AWS is more useful for beginners as it provides quicker and easier tracheal intubation.
-
(2007)
Acta Anaesthesiol Scand
, vol.51
, pp. 1378-1381
-
-
Miki, T.1
Inagawa, G.2
Kikuchi, T.3
-
20
-
-
34548602041
-
Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope
-
This article concludes laryngoscopy using the AWS involves less movement of the cervical spine compared to conventional laryngoscopy using the Macintosh laryngoscope
-
Hirabayashi Y, Fujita A, Seo N, Sugimoto H. Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope. Anaesthesia 2007; 62:1050-1055. This article concludes laryngoscopy using the AWS involves less movement of the cervical spine compared to conventional laryngoscopy using the Macintosh laryngoscope.
-
(2007)
Anaesthesia
, vol.62
, pp. 1050-1055
-
-
Hirabayashi, Y.1
Fujita, A.2
Seo, N.3
Sugimoto, H.4
-
21
-
-
34247844316
-
Airway scope versus Macintosh laryngoscope: A manikin study
-
This article concludes that the AWS performed as well as, and perhaps better than, the Macintosh laryngoscope when used on a mannequin
-
Hirabayashi Y. Airway scope versus Macintosh laryngoscope: a manikin study. Emerg Med J 2007; 24:357-358. This article concludes that the AWS performed as well as, and perhaps better than, the Macintosh laryngoscope when used on a mannequin.
-
(2007)
Emerg Med J
, vol.24
, pp. 357-358
-
-
Hirabayashi, Y.1
-
22
-
-
33750041338
-
Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anesthetists in easy and simulated difficult laryngscopy - a manikin study
-
Maharaj C, Higgins B, Harte B, Laffey J. Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anesthetists in easy and simulated difficult laryngscopy - a manikin study. Anaesthesia 2006; 61:1093-1099.
-
(2006)
Anaesthesia
, vol.61
, pp. 1093-1099
-
-
Maharaj, C.1
Higgins, B.2
Harte, B.3
Laffey, J.4
-
23
-
-
36849046763
-
Airtraq vs standard laryngoscopy by student paramedics and experience prehospital laryngoscopists managing a model of difficult intubation
-
A study comparing successful intubation in a mannequin model of a difficult intubation between the two techniques. In both inexperienced and experienced hands, the Airtraq was more successful
-
Woollard M, Lighton D, Mannion W, et al. Airtraq vs standard laryngoscopy by student paramedics and experience prehospital laryngoscopists managing a model of difficult intubation. Anaesthesia 2008; 63:26-31. A study comparing successful intubation in a mannequin model of a difficult intubation between the two techniques. In both inexperienced and experienced hands, the Airtraq was more successful.
-
(2008)
Anaesthesia
, vol.63
, pp. 26-31
-
-
Woollard, M.1
Lighton, D.2
Mannion, W.3
-
24
-
-
34548657984
-
Use of the Airtraq laryngoscope in a model of difficult intubation by prehospital providers not previously trained in laryngoscopy
-
An uncontrolled study using self-selected prehospital provider volunteers showed high first-time success in a mannequin model of a difficult intubation
-
Woollard M, Mannion W, Lighton D, et al. Use of the Airtraq laryngoscope in a model of difficult intubation by prehospital providers not previously trained in laryngoscopy. Anaesthesia 2007; 62:1061-1065. An uncontrolled study using self-selected prehospital provider volunteers showed high first-time success in a mannequin model of a difficult intubation.
-
(2007)
Anaesthesia
, vol.62
, pp. 1061-1065
-
-
Woollard, M.1
Mannion, W.2
Lighton, D.3
-
25
-
-
56849103992
-
-
Missaghi M, Krasser K, Lackner-Ausserhofer H, et al. 4. The Airtraq optical laryngoscope: experiences with a new disposable device for orotracheal intubation. Internet J Airway Manage 2007.
-
Missaghi M, Krasser K, Lackner-Ausserhofer H, et al. 4. The Airtraq optical laryngoscope: experiences with a new disposable device for orotracheal intubation. Internet J Airway Manage 2007.
-
-
-
-
26
-
-
33746818366
-
Comparison of direct and video-assisted views of the larynx during routine intubation
-
Kaplan M, Hagberg C, Ward D, et al. Comparison of direct and video-assisted views of the larynx during routine intubation. J Clin Anesth 2006; 18:357-362.
-
(2006)
J Clin Anesth
, vol.18
, pp. 357-362
-
-
Kaplan, M.1
Hagberg, C.2
Ward, D.3
-
27
-
-
0036971143
-
A new video laryngoscope - an aid to intubation and teaching
-
Kaplan M, Ward D, Bercia G. A new video laryngoscope - an aid to intubation and teaching. J Clin Anesth 2002; 14:622-626.
-
(2002)
J Clin Anesth
, vol.14
, pp. 622-626
-
-
Kaplan, M.1
Ward, D.2
Bercia, G.3
-
28
-
-
38349049152
-
The use of the Berci DCI Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation
-
This article concludes that video laryngoscopy confers benefits in the teaching of tracheal intubation by allowing both the student and instructor to share a view of the airway during intubation
-
Low D, Healy D, Rasburn N. The use of the Berci DCI Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation. Anaesthesia 2008; 63:195-201. This article concludes that video laryngoscopy confers benefits in the teaching of tracheal intubation by allowing both the student and instructor to share a view of the airway during intubation.
-
(2008)
Anaesthesia
, vol.63
, pp. 195-201
-
-
Low, D.1
Healy, D.2
Rasburn, N.3
-
29
-
-
36849010352
-
Teaching without a teacher: Developing competence with a Bullard laryngoscope using only a structured self-learning course and practicing on a mannequin
-
Novice users can learn to intubate a mannequin without necessarily needing expert instruction
-
Pott L, Santrock D. Teaching without a teacher: developing competence with a Bullard laryngoscope using only a structured self-learning course and practicing on a mannequin. J Clin Anesth 2007; 19:583-586. Novice users can learn to intubate a mannequin without necessarily needing expert instruction.
-
(2007)
J Clin Anesth
, vol.19
, pp. 583-586
-
-
Pott, L.1
Santrock, D.2
-
30
-
-
39149092983
-
Rigid indirect laryngoscope insertion techniques
-
A letter with a brief review of the literature and description of mouth opening
-
Henderson J, Suzuki A. Rigid indirect laryngoscope insertion techniques. Anaesthesia 2008; 63:323-324. A letter with a brief review of the literature and description of mouth opening.
-
(2008)
Anaesthesia
, vol.63
, pp. 323-324
-
-
Henderson, J.1
Suzuki, A.2
-
31
-
-
43449108565
-
Advancing the endotracheal tube smoothly when using the GlideScope [letter]
-
Neustein S. Advancing the endotracheal tube smoothly when using the GlideScope [letter]. Can J Anesth 2008; 55:314-315.
-
(2008)
Can J Anesth
, vol.55
, pp. 314-315
-
-
Neustein, S.1
-
32
-
-
34547606930
-
Difficult airway management following supratentorial craniotomy: A useful maneuver with a new device [letter]
-
A case report letter describing the method used with a McGrath
-
Osborn I, Behringer E, Kramer D. Difficult airway management following supratentorial craniotomy: a useful maneuver with a new device [letter]. Anesth Analg 2007; 105:552-553. A case report letter describing the method used with a McGrath.
-
(2007)
Anesth Analg
, vol.105
, pp. 552-553
-
-
Osborn, I.1
Behringer, E.2
Kramer, D.3
-
33
-
-
34547101989
-
-
Dhonneur G, Ndoko S, Amathieu R, et al. A comparison of two techniques for inserting the Airtraq laryngoscope in morbidly obese patients. Anaesthesia 2007; 62:774-777. A study comparing two different ways of inserting the Airtraq, both in lean and morbidly obese patients. A noteworthy result is that in the obese group, there was a higher risk of injury using either technique.
-
Dhonneur G, Ndoko S, Amathieu R, et al. A comparison of two techniques for inserting the Airtraq laryngoscope in morbidly obese patients. Anaesthesia 2007; 62:774-777. A study comparing two different ways of inserting the Airtraq, both in lean and morbidly obese patients. A noteworthy result is that in the obese group, there was a higher risk of injury using either technique.
-
-
-
-
34
-
-
23844550249
-
Considerations aimed at facilitating the use of the new GlideScope videolaryngoscope
-
Cuchillo J, Rodriguez M. Considerations aimed at facilitating the use of the new GlideScope videolaryngoscope. Can J Anesth 2005; 52:661-662.
-
(2005)
Can J Anesth
, vol.52
, pp. 661-662
-
-
Cuchillo, J.1
Rodriguez, M.2
-
35
-
-
34250367441
-
Angled or curved stylet for intubation with the GlideScope [letter]
-
Dupanovic M. Angled or curved stylet for intubation with the GlideScope [letter]. Can J Anesth 2007; 54:487-488.
-
(2007)
Can J Anesth
, vol.54
, pp. 487-488
-
-
Dupanovic, M.1
-
36
-
-
33846644972
-
-
Jones P, Turkstra T, Armstrong K, et al. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anesth 2007; 54:21-27. A randomized trial comparing four different stylet shapes. Patients intubated with the GlideScope using a 90° stylet angle provided the best result and should be the initial configuration. Camber of the ETT (i.e., rotating the ETT through 180° around the axis of the stylet) did not appear to influence the time to intubation.
-
Jones P, Turkstra T, Armstrong K, et al. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anesth 2007; 54:21-27. A randomized trial comparing four different stylet shapes. Patients intubated with the GlideScope using a 90° stylet angle provided the best result and should be the initial configuration. Camber of the ETT (i.e., rotating the ETT through 180° around the axis of the stylet) did not appear to influence the time to intubation.
-
-
-
-
37
-
-
34249798746
-
Case series: The McGrath videolaryngoscope - an initial clinical evaluation
-
Shippey B, Ray D, McKeown D. Case series: the McGrath videolaryngoscope - an initial clinical evaluation. Can J Anesth 2007; 54:307-313.
-
(2007)
Can J Anesth
, vol.54
, pp. 307-313
-
-
Shippey, B.1
Ray, D.2
McKeown, D.3
-
38
-
-
41349091260
-
The GlideScope-specific rigid stylet to facilitate tracheal intubation with the GlideScope [letter]
-
Neustein S. The GlideScope-specific rigid stylet to facilitate tracheal intubation with the GlideScope [letter]. Can J Anesth 2008; 55:196-197.
-
(2008)
Can J Anesth
, vol.55
, pp. 196-197
-
-
Neustein, S.1
-
40
-
-
47149103119
-
Use of the Endoflex endotracheal tube as a stylet-free alternative in GlideScope intubations
-
A letter describing equipment for stylet-free intubation using a GlideScope
-
Phua D, Wang C, Yoong C. Use of the Endoflex endotracheal tube as a stylet-free alternative in GlideScope intubations. Can J Anesth 2008; 55:473-474. A letter describing equipment for stylet-free intubation using a GlideScope.
-
(2008)
Can J Anesth
, vol.55
, pp. 473-474
-
-
Phua, D.1
Wang, C.2
Yoong, C.3
-
41
-
-
34748881221
-
Comparing the Airtraq with the LMA CTrach (response)
-
A response letter with a discussion on the types of instruments, the place of these instruments in the difficult airway algorithm, and the experience in France
-
Dhonneur G, Ndoko S. Comparing the Airtraq with the LMA CTrach (response). Anesthesiology 2007; 107:675-676. A response letter with a discussion on the types of instruments, the place of these instruments in the difficult airway algorithm, and the experience in France.
-
(2007)
Anesthesiology
, vol.107
, pp. 675-676
-
-
Dhonneur, G.1
Ndoko, S.2
-
42
-
-
38749123445
-
Videolaryngsoscopy for tracheal intubation: The guide channel or steering techniques for endotracheal tube placement? [letter]
-
Savoldelli G, Schiffer E. Videolaryngsoscopy for tracheal intubation: the guide channel or steering techniques for endotracheal tube placement? [letter]. Can J Anesth 2008; 55:59-60.
-
(2008)
Can J Anesth
, vol.55
, pp. 59-60
-
-
Savoldelli, G.1
Schiffer, E.2
-
43
-
-
33748592865
-
GlideScope-assisted awake fiberoptic intubation: Initial experience in 13 patients [letter]
-
Xue F, Li C, Zhang G, et al. GlideScope-assisted awake fiberoptic intubation: initial experience in 13 patients [letter]. Anaesthesia 2006; 61:1014-1015.
-
(2006)
Anaesthesia
, vol.61
, pp. 1014-1015
-
-
Xue, F.1
Li, C.2
Zhang, G.3
-
44
-
-
36549002744
-
A difficult airway case with GlideScope-assisted fiberoptic intubation
-
Vitin A, Erdman J. A difficult airway case with GlideScope-assisted fiberoptic intubation. J Clin Anesth 2007; 19:564-565.
-
(2007)
J Clin Anesth
, vol.19
, pp. 564-565
-
-
Vitin, A.1
Erdman, J.2
-
45
-
-
23644432644
-
The use of a gum elastic bougie in combination with a videolaryngoscope
-
Heitz J, Mastrando D. The use of a gum elastic bougie in combination with a videolaryngoscope. J Clin Anesth 2005; 17:408-409.
-
(2005)
J Clin Anesth
, vol.17
, pp. 408-409
-
-
Heitz, J.1
Mastrando, D.2
-
46
-
-
56549100185
-
Endotracheal tube as a guide for an Eschmann gum elastic bougie to aid tracheal intubation using the McGrath or GlideScope videolaryngoscopes
-
in press
-
Budde A, Pott L. Endotracheal tube as a guide for an Eschmann gum elastic bougie to aid tracheal intubation using the McGrath or GlideScope videolaryngoscopes. J Clin Anesth 2008 (in press).
-
(2008)
J Clin Anesth
-
-
Budde, A.1
Pott, L.2
-
47
-
-
36849014481
-
Successful airway management of a patient with a known difficult airway with the Direct Coupler Interface Video Laryngoscope
-
Hagberg C, Vogt-Harenkamp C, Iannucci D. Successful airway management of a patient with a known difficult airway with the Direct Coupler Interface Video Laryngoscope. J Clin Anesth 2007; 19:629-631.
-
(2007)
J Clin Anesth
, vol.19
, pp. 629-631
-
-
Hagberg, C.1
Vogt-Harenkamp, C.2
Iannucci, D.3
-
48
-
-
45849122418
-
The modified ventilating tube changer to facilitate tracheal intubation using the GlideScope in patients with a limited mouth opening [letter]
-
Xue F, Yang Q, He N, Xu Y. The modified ventilating tube changer to facilitate tracheal intubation using the GlideScope in patients with a limited mouth opening [letter]. Br J Anaesthesia 2008; 101:126-127.
-
(2008)
Br J Anaesthesia
, vol.101
, pp. 126-127
-
-
Xue, F.1
Yang, Q.2
He, N.3
Xu, Y.4
-
49
-
-
33846629539
-
Tracheal intubation using the GlideScope with a combined curved pipe stylet, and endotracheal tube introducer [letter]
-
A letter describing an interesting technique using a bougie through a pipe stylet
-
Muallem M, Baraka A. Tracheal intubation using the GlideScope with a combined curved pipe stylet, and endotracheal tube introducer [letter]. Can J Anesth 2007; 54:77-78. A letter describing an interesting technique using a bougie through a pipe stylet.
-
(2007)
Can J Anesth
, vol.54
, pp. 77-78
-
-
Muallem, M.1
Baraka, A.2
-
50
-
-
41949120312
-
A new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: A randomized comparative study
-
This article found that in patients with a stabilized neck, the Pentax AWS provided a better view of the glottis and a higher success rate of tracheal intubation, compared with the conventional Macintosh laryngoscope
-
Enomoto Y, Asai T, Arai T, et al. A new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesthesia 2008; 100:544-548. This article found that in patients with a stabilized neck, the Pentax AWS provided a better view of the glottis and a higher success rate of tracheal intubation, compared with the conventional Macintosh laryngoscope.
-
(2008)
Br J Anaesthesia
, vol.100
, pp. 544-548
-
-
Enomoto, Y.1
Asai, T.2
Arai, T.3
-
51
-
-
44249085205
-
Direct versus indirect laryngoscopic visualization in human endotracheal intubation: A tool for virtual anesthesia practice and teleanesthesiology
-
This article compares the view of the glottic opening using direct against indirect laryngoscopy
-
Boedeker B, Berg B, Bernhagen M, et al. Direct versus indirect laryngoscopic visualization in human endotracheal intubation: a tool for virtual anesthesia practice and teleanesthesiology. Stud Health Technol Inform 2008; 132:31-38. This article compares the view of the glottic opening using direct against indirect laryngoscopy.
-
(2008)
Stud Health Technol Inform
, vol.132
, pp. 31-38
-
-
Boedeker, B.1
Berg, B.2
Bernhagen, M.3
-
52
-
-
34248547057
-
Endotracheal intubation using virtual images: Learning with the mobile telementoring intubating video laryngoscope
-
This article discusses the advantages of video laryngoscopy for training students in intubation
-
Boedeker B, Hoffman S, Murray W. Endotracheal intubation using virtual images: learning with the mobile telementoring intubating video laryngoscope. Stud Health Technol Inform 2007; 125:49-54. This article discusses the advantages of video laryngoscopy for training students in intubation.
-
(2007)
Stud Health Technol Inform
, vol.125
, pp. 49-54
-
-
Boedeker, B.1
Hoffman, S.2
Murray, W.3
-
53
-
-
33645455334
-
Seeing is believing: The importance of video laryngoscopy in teaching and in managing the difficult airway
-
Kaplan M, Ward D, Hagberg C, et al. Seeing is believing: the importance of video laryngoscopy in teaching and in managing the difficult airway. Surg Endosc 2006; 20:S479-S483.
-
(2006)
Surg Endosc
, vol.20
-
-
Kaplan, M.1
Ward, D.2
Hagberg, C.3
-
54
-
-
0038394393
-
Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization
-
Agro F, Barzoi G, Montecchia F. Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization. Br J Anaesthesia 2003; 90:705-706.
-
(2003)
Br J Anaesthesia
, vol.90
, pp. 705-706
-
-
Agro, F.1
Barzoi, G.2
Montecchia, F.3
-
55
-
-
0036816451
-
Management choices for the difficult airway by anesthesiologists in Canada
-
Jenkins K, Wong D, Correa R. Management choices for the difficult airway by anesthesiologists in Canada. Can J Anesth 2002; 49:850-856.
-
(2002)
Can J Anesth
, vol.49
, pp. 850-856
-
-
Jenkins, K.1
Wong, D.2
Correa, R.3
-
56
-
-
26944432273
-
-
Hsaio W, Lin Y, Wu H, Chen C. Does a new videolaryngoscope (GlideScope) provide a better glottic exposure? Acta Anaesthesiol Taiwanica 2005; 43:147-151.
-
Hsaio W, Lin Y, Wu H, Chen C. Does a new videolaryngoscope (GlideScope) provide a better glottic exposure? Acta Anaesthesiol Taiwanica 2005; 43:147-151.
-
-
-
-
57
-
-
33846605602
-
Complications associated with the use of the GlideScope videolaryngoscope
-
Cooper R. Complications associated with the use of the GlideScope videolaryngoscope. Can J Anesth 2007; 54:54-57.
-
(2007)
Can J Anesth
, vol.54
, pp. 54-57
-
-
Cooper, R.1
-
58
-
-
34249000358
-
Penetrating injury of the soft palate during GlideScope intubation
-
Hsu W, Hsu S, Lee Y, et al. Penetrating injury of the soft palate during GlideScope intubation. Anesth Analg 2007; 104:1609-1610.
-
(2007)
Anesth Analg
, vol.104
, pp. 1609-1610
-
-
Hsu, W.1
Hsu, S.2
Lee, Y.3
-
59
-
-
34249014023
-
Anterior tonsillar pillar perforation during GlideScope video laryngoscopy
-
A letter describing an injury to a patient while using a GlideScope
-
Malik A, Frogel J. Anterior tonsillar pillar perforation during GlideScope video laryngoscopy. Anesth Analg 2007; 104:1610-1611. A letter describing an injury to a patient while using a GlideScope.
-
(2007)
Anesth Analg
, vol.104
, pp. 1610-1611
-
-
Malik, A.1
Frogel, J.2
-
60
-
-
21344439841
-
Movement of the upper cervical spine during laryngoscopy: A comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope
-
Rudolph C, Schneider J, Wallenborn J, Schaffranietz L. Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope. Anaesthesia 2005; 60:668-672.
-
(2005)
Anaesthesia
, vol.60
, pp. 668-672
-
-
Rudolph, C.1
Schneider, J.2
Wallenborn, J.3
Schaffranietz, L.4
-
61
-
-
13244271956
-
Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the Bonfils fibrescope and the Intubating Laryngeal Mask Airway
-
Wahlen B, Gercek E. Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the Bonfils fibrescope and the Intubating Laryngeal Mask Airway. Eur J Anaesth 2004; 21:907-913.
-
(2004)
Eur J Anaesth
, vol.21
, pp. 907-913
-
-
Wahlen, B.1
Gercek, E.2
-
62
-
-
34250891900
-
-
Maharaj C, Buckley E, Harte B1 Laffey J. Endotracheal intubation in patients with cervical spine immobilization. Anesthesiology 2007; 107:53-59. A randomized study using 40 normal patients who were intubated while in a cervical collar. The Airtraq was quicker, easier, and associated with less blood pressure and heart rate changes.
-
Maharaj C, Buckley E, Harte B1 Laffey J. Endotracheal intubation in patients with cervical spine immobilization. Anesthesiology 2007; 107:53-59. A randomized study using 40 normal patients who were intubated while in a cervical collar. The Airtraq was quicker, easier, and associated with less blood pressure and heart rate changes.
-
-
-
-
63
-
-
38449091187
-
Upper cervical spine movement during intubation: Fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope and Macintosh laryngoscope
-
This article concluded that compared with the Macintosh or McCoy laryngoscope, the AWS produced less movement of upper C spine during intubation in patients with a normal C spine
-
Maruyama K, Yamada T, Kawakami R, et al. Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope and Macintosh laryngoscope. Br J Anaesthesia 2008; 100:120-124. This article concluded that compared with the Macintosh or McCoy laryngoscope, the AWS produced less movement of upper C spine during intubation in patients with a normal C spine.
-
(2008)
Br J Anaesthesia
, vol.100
, pp. 120-124
-
-
Maruyama, K.1
Yamada, T.2
Kawakami, R.3
-
64
-
-
38349019433
-
-
Maharaj C, Costello J, Harte B, Laffey J. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia 2008; 63:182-188. A randomized study using 40 patients with at least three indicators for a potentially difficult intubation. The Airtraq was successful in four patients where the Macintosh laryngoscope was initially not successful. The Airtraq was quicker, easier and associated with less blood pressure and heart rate changes.
-
Maharaj C, Costello J, Harte B, Laffey J. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia 2008; 63:182-188. A randomized study using 40 patients with at least three indicators for a potentially difficult intubation. The Airtraq was successful in four patients where the Macintosh laryngoscope was initially not successful. The Airtraq was quicker, easier and associated with less blood pressure and heart rate changes.
-
-
-
-
65
-
-
39149090974
-
Can force be used as a surrogate measure for difficult laryngoscopy?
-
This letter discusses the relationship between force required during laryngoscopy and the difficulty of laryngoscopy
-
Duggan J, Syndercombe A, Haig T, Thompson R. Can force be used as a surrogate measure for difficult laryngoscopy? Anaesthesia 2008; 63:318-319. This letter discusses the relationship between force required during laryngoscopy and the difficulty of laryngoscopy.
-
(2008)
Anaesthesia
, vol.63
, pp. 318-319
-
-
Duggan, J.1
Syndercombe, A.2
Haig, T.3
Thompson, R.4
-
66
-
-
56849103718
-
-
editors. Management of the difficult and failed airway. New York: McGraw-Hill Medical;, An excellent review in an excellent textbook
-
Morris I. Flexible fiberoptic intubation. In: Hung O, Murphy M, editors. Management of the difficult and failed airway. New York: McGraw-Hill Medical; 2008. pp. 123-138. An excellent review in an excellent textbook.
-
(2008)
Flexible fiberoptic intubation
, pp. 123-138
-
-
Morris, I.1
-
67
-
-
56849126152
-
Flexible fiberoptic intubation
-
Walls R, Murphy M, Luten R, Schneider R, editors, 2nd ed. Philadelphia: Lippincott Williams & Wilkins;
-
Murphy M. Flexible fiberoptic intubation. In: Walls R, Murphy M, Luten R, Schneider R, editors. Manual of emergency airway management, 2nd ed. Philadelphia: Lippincott Williams & Wilkins; 2004. pp. 127-134.
-
(2004)
Manual of emergency airway management
, pp. 127-134
-
-
Murphy, M.1
-
68
-
-
76749118301
-
-
Wheeler M, Ovassapian A. Fiberoptic endoscopy-aided techniques. In: Hagberg C, editor. Benumof's airway management, 2nd ed. Philadelphia: Mosby Elsevier; 2007. pp. 399-438. A very comprehensive and well illustrated review in an outstanding textbook.
-
Wheeler M, Ovassapian A. Fiberoptic endoscopy-aided techniques. In: Hagberg C, editor. Benumof's airway management, 2nd ed. Philadelphia: Mosby Elsevier; 2007. pp. 399-438. A very comprehensive and well illustrated review in an outstanding textbook.
-
-
-
-
69
-
-
33845735496
-
Awake fiberoptic intubation using an optical stylet in an anticipated difficult airway
-
Kovacs G, Law A, Petrie D. Awake fiberoptic intubation using an optical stylet in an anticipated difficult airway. Ann Emerg Med 2007; 49:81-83.
-
(2007)
Ann Emerg Med
, vol.49
, pp. 81-83
-
-
Kovacs, G.1
Law, A.2
Petrie, D.3
-
70
-
-
36849012679
-
(Airway Scope) for awake tracheal intubation
-
A case report with a clear photograph demonstrating the arrangement for suction and topical anesthesia
-
Suzuki A, Kunisawa T, Takahata O, et al. (Airway Scope) for awake tracheal intubation. J Clin Anesth 2007; 19:642-646. A case report with a clear photograph demonstrating the arrangement for suction and topical anesthesia.
-
(2007)
J Clin Anesth
, vol.19
, pp. 642-646
-
-
Suzuki, A.1
Kunisawa, T.2
Takahata, O.3
-
71
-
-
34250667076
-
Airtraq for awake tracheal intubation
-
Suzuki A, Toyama Y, Iwasaki H. Airtraq for awake tracheal intubation. Anaesthesia 2007; 62:746-747.
-
(2007)
Anaesthesia
, vol.62
, pp. 746-747
-
-
Suzuki, A.1
Toyama, Y.2
Iwasaki, H.3
-
72
-
-
37549032117
-
Subcutaneous cervical and facial emphysema with the use of the Bonfils fiberscope and high-flow oxygen insufflation
-
Hemmerling T, Bracco D. Subcutaneous cervical and facial emphysema with the use of the Bonfils fiberscope and high-flow oxygen insufflation. Anesth Analg 2008; 106:260-262.
-
(2008)
Anesth Analg
, vol.106
, pp. 260-262
-
-
Hemmerling, T.1
Bracco, D.2
-
73
-
-
33745041971
-
Bonfils semirigid endoscope for guidance during percutaneous tracheostomy
-
Buehner U, Oram J, Elliot S, et al. Bonfils semirigid endoscope for guidance during percutaneous tracheostomy. Anaesthesia 2006; 60:665-670.
-
(2006)
Anaesthesia
, vol.60
, pp. 665-670
-
-
Buehner, U.1
Oram, J.2
Elliot, S.3
-
74
-
-
45849085687
-
Positioning the tracheal tube during percutaneous tracheostomy: Another use for videolaryngoscopy [letter]
-
This letter discusses potential advantages of video laryngoscopy for maintaining ETT position during percutaneous tracheostomy against direct laryngoscopy
-
Gilles M, Smith J, Langrish C. Positioning the tracheal tube during percutaneous tracheostomy: another use for videolaryngoscopy [letter]. Br J Anaesthesia 2008; 101:129. This letter discusses potential advantages of video laryngoscopy for maintaining ETT position during percutaneous tracheostomy against direct laryngoscopy.
-
(2008)
Br J Anaesthesia
, vol.101
, pp. 129
-
-
Gilles, M.1
Smith, J.2
Langrish, C.3
-
75
-
-
35449007716
-
The Airtraq to facilitate endotracheal tube exchange in critically ill, difficult-to-intubate patient
-
Matioc A, Lopukhin O. The Airtraq to facilitate endotracheal tube exchange in critically ill, difficult-to-intubate patient. J Clin Anesth 2007; 19:485-488.
-
(2007)
J Clin Anesth
, vol.19
, pp. 485-488
-
-
Matioc, A.1
Lopukhin, O.2
-
76
-
-
85047696151
-
Description and first clinical application of airway scope for tracheal intubation
-
Koyama J, Aoyama T, Kusano Y. Description and first clinical application of airway scope for tracheal intubation. J Neurosurg Anesthesiol 2006; 18:247-250.
-
(2006)
J Neurosurg Anesthesiol
, vol.18
, pp. 247-250
-
-
Koyama, J.1
Aoyama, T.2
Kusano, Y.3
-
77
-
-
37549039836
-
The Pentax AWS video laryngoscope: The first experience in one hundred patients
-
A case series of 100 patients with no complications. Clear photographs and description of unit
-
Asai T, Enomoto Y, Shimizu K, et al. The Pentax AWS video laryngoscope: the first experience in one hundred patients. Anesth Analg 2008; 106:257-259. A case series of 100 patients with no complications. Clear photographs and description of unit.
-
(2008)
Anesth Analg
, vol.106
, pp. 257-259
-
-
Asai, T.1
Enomoto, Y.2
Shimizu, K.3
-
78
-
-
34548619060
-
A monitor to facilitate use of the Airtraq laryngoscope
-
A description of a video camera that can be attached to the Airtraq
-
Hirabayashi Y, Seo N. A monitor to facilitate use of the Airtraq laryngoscope. Anaesthesia 2007; 62:1081. A description of a video camera that can be attached to the Airtraq.
-
(2007)
Anaesthesia
, vol.62
, pp. 1081
-
-
Hirabayashi, Y.1
Seo, N.2
|