메뉴 건너뛰기




Volumn 91, Issue 3, 2003, Pages 408-418

New options for airway management: Intubating fibreoptic stylets

Author keywords

Airway, difficult; Equipment, fibreoptic style; Intubation, tracheal

Indexed keywords

BRONCHOSCOPE; COST BENEFIT ANALYSIS; ENDOTRACHEAL TUBE; EQUIPMENT DESIGN; FIBER OPTICS; HOARSENESS; LARYNGOSCOPE; LARYNGOSCOPY; PRIORITY JOURNAL; PROCESS MODEL; REVIEW; SORE THROAT; VIDEORECORDING;

EID: 0042830398     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/aeg011     Document Type: Review
Times cited : (73)

References (41)
  • 1
    • 0034108490 scopus 로고    scopus 로고
    • The Seeing Stylet: A new device for tracheal intubation
    • Agro F, Cataldo R, Carassiti M, Costa F. The Seeing Stylet: a new device for tracheal intubation. Resuscitation 2000; 44: 177-80
    • (2000) Resuscitation , vol.44 , pp. 177-180
    • Agro, F.1    Cataldo, R.2    Carassiti, M.3    Costa, F.4
  • 2
    • 85045230822 scopus 로고    scopus 로고
    • Jaw thrust maneuver for endotracheal intubation using a fiberoptic stylet
    • Aoyama K, Takenaka I, Nagaoka E, Kadoya T. Jaw thrust maneuver for endotracheal intubation using a fiberoptic stylet. Anesth Analg 2000; 90: 1455-9
    • (2000) Anesth. Analg. , vol.90 , pp. 1455-1459
    • Aoyama, K.1    Takenaka, I.2    Nagaoka, E.3    Kadoya, T.4
  • 3
    • 0018604222 scopus 로고
    • Laryngeal and tracheal problems in patients with central nervous system and spinal disorders
    • Applebaum EL. Laryngeal and tracheal problems in patients with central nervous system and spinal disorders. Otolaryngol Clin North Am 1979; 12: 829-35
    • (1979) Otolaryngol. Clin. North Am. , vol.12 , pp. 829-835
    • Applebaum, E.L.1
  • 4
    • 0018645010 scopus 로고
    • Optical stylet: An aid to intubation and teaching
    • Berci G, Katz R. Optical stylet: an aid to intubation and teaching. Ann Otol Rhinol Laryngol 1979; 88: 828-31
    • (1979) Ann. Otol. Rhinol. Laryngol. , vol.88 , pp. 828-831
    • Berci, G.1    Katz, R.2
  • 5
    • 0034964174 scopus 로고    scopus 로고
    • Comparison of two video-assisted techniques for the difficult intubation
    • Biro P, Weiss M. Comparison of two video-assisted techniques for the difficult intubation. Acta Anaesthesiol Scand 2001; 45: 761-5
    • (2001) Acta Anaesthesiol. Scand. , vol.45 , pp. 761-765
    • Biro, P.1    Weiss, M.2
  • 6
    • 0033817346 scopus 로고    scopus 로고
    • Comparison of a new video-optical intubation stylet versus the conventional malleable stylet in simulated difficult tracheal intubation
    • Biro P, Weiss M, Gerber A, Pasch T. Comparison of a new video-optical intubation stylet versus the conventional malleable stylet in simulated difficult tracheal intubation. Anaesthesia 2000; 55: 886-9
    • (2000) Anaesthesia , vol.55 , pp. 886-889
    • Biro, P.1    Weiss, M.2    Gerber, A.3    Pasch, T.4
  • 7
    • 0020554091 scopus 로고
    • Schwierige Intubation bei Pierre-Robin-Kindern, eine neue Methode: Der retromolar Weg
    • Bonfils P. Schwierige Intubation bei Pierre-Robin-Kindern, eine neue Methode: der retromolar Weg. Anaesthesist 1983; 32: 363-7
    • (1983) Anaesthesist , vol.32 , pp. 363-367
    • Bonfils, P.1
  • 8
    • 0033654529 scopus 로고    scopus 로고
    • Fibre-optic aided bougie (FAB) for simulated difficult tracheal intubation
    • Chiu JW, Goh MH, Ip-Yam PC. Fibre-optic aided bougie (FAB) for simulated difficult tracheal intubation. Ann Acad Med Singapore 2000; 29: 47-9
    • (2000) Ann. Acad. Med. Singapore , vol.29 , pp. 47-49
    • Chiu, J.W.1    Goh, M.H.2    Ip-Yam, P.C.3
  • 9
    • 0019370888 scopus 로고
    • Adaptation of the fiberoptic laryngoscope for tracheal intubation with small diameter tubes
    • Ford RW. Adaptation of the fiberoptic laryngoscope for tracheal intubation with small diameter tubes. Can Anaesth Soc J 1981; 28: 479-80
    • (1981) Can. Anaesth. Soc. J. , vol.28 , pp. 479-480
    • Ford, R.W.1
  • 10
    • 0030859789 scopus 로고    scopus 로고
    • Clinical evaluation of a new visualized endotracheal tube
    • Frass M, Kofler J, Thalhammer F, et al. Clinical evaluation of a new visualized endotracheal tube. Anesthesiology 1997; 87: 1262-3
    • (1997) Anesthesiology , vol.87 , pp. 1262-1263
    • Frass, M.1    Kofler, J.2    Thalhammer, F.3
  • 11
    • 0032075740 scopus 로고    scopus 로고
    • Performance of a plastic optical fiber stylet for tracheal intubation of a dog
    • Gravenstein D, Lampotang S, Melker R, Doviak R. Performance of a plastic optical fiber stylet for tracheal intubation of a dog. J Clin Monit Comput 1998; 14: 271-4
    • (1998) J. Clin. Monit. Comput. , vol.14 , pp. 271-274
    • Gravenstein, D.1    Lampotang, S.2    Melker, R.3    Doviak, R.4
  • 12
    • 0032846515 scopus 로고    scopus 로고
    • Clinical assessment of a plastic optical fiber stylet for human tracheal intubation
    • Gravenstein D, Melker RJ, Lampotang S. Clinical assessment of a plastic optical fiber stylet for human tracheal intubation. Anesthesiology 1999; 91: 648-53
    • (1999) Anesthesiology , vol.91 , pp. 648-653
    • Gravenstein, D.1    Melker, R.J.2    Lampotang, S.3
  • 13
    • 0018648412 scopus 로고
    • The optical stylet - A new intubation technique for adults and children with specific reference to teaching
    • Katz RL, Berci G. The optical stylet - a new intubation technique for adults and children with specific reference to teaching. Anesthesiology 1979; 51: 251-4
    • (1979) Anesthesiology , vol.51 , pp. 251-254
    • Katz, R.L.1    Berci, G.2
  • 14
    • 0035216643 scopus 로고    scopus 로고
    • Use of the fibreoptic stylet scope (Styletscope™) reduces the hemodynamic response to intubation in normotensive and hypertensive patients
    • Kimura A, Yamakage M, Chen X, Kamada Y, Namiki A. Use of the fibreoptic stylet scope (Styletscope™) reduces the hemodynamic response to intubation in normotensive and hypertensive patients. Can J Anaesth 2001; 48: 919-23
    • (2001) Can. J. Anaesth. , vol.48 , pp. 919-923
    • Kimura, A.1    Yamakage, M.2    Chen, X.3    Kamada, Y.4    Namiki, A.5
  • 15
    • 0034072129 scopus 로고    scopus 로고
    • An efficient technique for tracheal intubation using the StyletScope alone
    • Kitamura T, Yamada Y. An efficient technique for tracheal intubation using the StyletScope alone. Anesthesiology 2000; 92: 1210-11
    • (2000) Anesthesiology , vol.92 , pp. 1210-1211
    • Kitamura, T.1    Yamada, Y.2
  • 16
    • 0032712611 scopus 로고    scopus 로고
    • Efficiency of a new fiberoptic Styletscope in tracheal intubation
    • Kitamura T, Yamada Y, Du HL, Hanaoka K. Efficiency of a new fiberoptic Styletscope in tracheal intubation. Anesthesiology 1999; 91: 1628-32
    • (1999) Anesthesiology , vol.91 , pp. 1628-1632
    • Kitamura, T.1    Yamada, Y.2    Du, H.L.3    Hanaoka, K.4
  • 17
    • 0029243743 scopus 로고
    • Hybrid intubation technique for the management of a difficult airway: A case report
    • Lupien AE, Taylor C. Hybrid intubation technique for the management of a difficult airway: a case report. AANA J 1995; 63: 50-2
    • (1995) AANA J. , vol.63 , pp. 50-52
    • Lupien, A.E.1    Taylor, C.2
  • 19
    • 0014102275 scopus 로고
    • A fibre-optic endoscope used for nasal intubation
    • Murphy P. A fibre-optic endoscope used for nasal intubation. Anaesthesia 1967; 22: 489-91
    • (1967) Anaesthesia , vol.22 , pp. 489-491
    • Murphy, P.1
  • 20
    • 0003931410 scopus 로고
    • Fiberoptic endoscopy in Anesthesia
    • Chicago: Yearbook Medical Publishers (now Mosby)
    • Patil VU. Fiberoptic endoscopy in Anesthesia. Chicago: Yearbook Medical Publishers (now Mosby), 1983; 9-15
    • (1983) , pp. 9-15
    • Patil, V.U.1
  • 21
    • 0042356098 scopus 로고    scopus 로고
    • ED clinical trial of a fiberoptic-enhanced endotracheal tube for intubation, monitoring, tube placement, confirmation and difficult airway management
    • Annual meeting of the Society for Academic Emergency Medicine, Washington DC, May
    • Pollack CP, Bradley BB, Jordon RC, Mackin RA. ED clinical trial of a fiberoptic-enhanced endotracheal tube for intubation, monitoring, tube placement, confirmation and difficult airway management. Annual meeting of the Society for Academic Emergency Medicine, Washington DC, May 1997
    • (1997)
    • Pollack, C.P.1    Bradley, B.B.2    Jordon, R.C.3    Mackin, R.A.4
  • 22
    • 4243524212 scopus 로고    scopus 로고
    • Fiberoptic-enhanced endotracheal tube for bedside teaching of intubation skills
    • Annual meeting of the Society for Academic Emergency Medicine, Washington DC, May
    • Pollack CP, Bradley BB, Jordon RC, Mackin RA, Marrriot W. Fiberoptic-enhanced endotracheal tube for bedside teaching of intubation skills. Annual meeting of the Society for Academic Emergency Medicine, Washington DC, May 1997
    • (1997)
    • Pollack, C.P.1    Bradley, B.B.2    Jordon, R.C.3    Mackin, R.A.4    Marrriot, W.5
  • 24
    • 0029036061 scopus 로고
    • Mycobacterial contamination of fibreoptic bronchoscopes
    • Reeves DS, Brown NM. Mycobacterial contamination of fibreoptic bronchoscopes. J Hosp Infect 1995; 30 [Suppl]; 531-6
    • (1995) J. Hosp. Infect. , vol.30 , Issue.SUPPL. , pp. 531-536
    • Reeves, D.S.1    Brown, N.M.2
  • 25
    • 0030329531 scopus 로고    scopus 로고
    • Clinical experiences with fiberoptic intubation with the Bonfils intubation fiberscope
    • Rudolph C, Schlender M. Clinical experiences with fiberoptic intubation with the Bonfils intubation fiberscope. Anaesthesiol Reanim 1996; 21: 127-30
    • (1996) Anaesthesiol. Reanim. , vol.21 , pp. 127-130
    • Rudolph, C.1    Schlender, M.2
  • 26
    • 0023238545 scopus 로고
    • Difficult tracheal intubation: A retrospective study
    • Samsoon GLT, Young RB. Difficult tracheal intubation: a retrospective study. Anaesthesia 1987; 42: 487-90
    • (1987) Anaesthesia , vol.42 , pp. 487-490
    • Samsoon, G.L.T.1    Young, R.B.2
  • 27
    • 0032784219 scopus 로고    scopus 로고
    • Swift conversion from laryngoscopic to fiberoptic intubation with a new, handy fiberoptic stylet
    • Saruki N, Saito S, Sato J, Kon N, Tozawa R. Swift conversion from laryngoscopic to fiberoptic intubation with a new, handy fiberoptic stylet. Anesth Analg 1999; 89: 526-8
    • (1999) Anesth. Analg. , vol.89 , pp. 526-528
    • Saruki, N.1    Saito, S.2    Sato, J.3    Kon, N.4    Tozawa, R.5
  • 28
    • 0030293283 scopus 로고    scopus 로고
    • A new indication for the Cook critical care Rapiscope
    • Selwyn D, Spiers P. A new indication for the Cook critical care Rapiscope. Anaesthesia 1996; 51: 1076
    • (1996) Anaesthesia , vol.51 , pp. 1076
    • Selwyn, D.1    Spiers, P.2
  • 29
    • 0021323106 scopus 로고
    • Fiberoptic stylet laryngoscope and sitting position for tracheal intubation in acute superior vena cava syndrome
    • Shapiro HM, Sanford TJ, Schaldach AL. Fiberoptic stylet laryngoscope and sitting position for tracheal intubation in acute superior vena cava syndrome. Anesth Analg 1984; 63: 161
    • (1984) Anesth. Analg. , vol.63 , pp. 161
    • Shapiro, H.M.1    Sanford, T.J.2    Schaldach, A.L.3
  • 30
    • 0032902340 scopus 로고    scopus 로고
    • New "seeing" stylet-scope and method for the management of the difficult airway
    • Shikani AH. New "seeing" stylet-scope and method for the management of the difficult airway. Otolaryngol Head Neck Surg 1999; 120: 113-6
    • (1999) Otolaryngol. Head Neck Surg. , vol.120 , pp. 113-116
    • Shikani, A.H.1
  • 31
    • 0031040567 scopus 로고    scopus 로고
    • Learning curves for flbreoptic nasotracheal intubation when using the endoscopic video camera
    • Smith JE, Jackson APF, Hurdley J, Clifton PJM. Learning curves for flbreoptic nasotracheal intubation when using the endoscopic video camera. Anaesthesia 1997; 52: 101-6
    • (1997) Anaesthesia , vol.52 , pp. 101-106
    • Smith, J.E.1    Jackson, A.P.F.2    Hurdley, J.3    Clifton, P.J.M.4
  • 32
    • 0015503103 scopus 로고
    • A flexible fiber optic laryngoscope
    • 11
    • Stiles CM, Stiles QR, Denson JS. A flexible fiber optic laryngoscope. JAMA 1972; 11; 221 (11): 1246-7
    • (1972) JAMA , vol.221 , Issue.11 , pp. 1246-1247
    • Stiles, C.M.1    Stiles, Q.R.2    Denson, J.S.3
  • 33
    • 0016975770 scopus 로고
    • Use of the fiberoptic laryngoscope for difficult tracheal intubation
    • Wang JF, Reves JG, Corssen G. Use of the fiberoptic laryngoscope for difficult tracheal intubation. Ala J Med Sci 1976; 13: 247-51
    • (1976) Ala J. Med. Sci. , vol.13 , pp. 247-251
    • Wang, J.F.1    Reves, J.G.2    Corssen, G.3
  • 34
    • 33644570614 scopus 로고    scopus 로고
    • Video-assisted tracheal intubation through the Fastrach-LMA using a video-optical intubation stylet
    • Weiss M, Goldmann K, Schwarz U. Video-assisted tracheal intubation through the Fastrach-LMA using a video-optical intubation stylet. Internet J Anesthesiol 1999; 3N2 http://www.ispub.com/journals/IJA/Vol3N2/ilma.htm
    • (1999) Internet J. Anesthesiol.
    • Weiss, M.1    Goldmann, K.2    Schwarz, U.3
  • 35
    • 0034837331 scopus 로고    scopus 로고
    • Video-intuboscopic assistance is a useful aid to tracheal intubaton in pediatric patients
    • Weiss M, Hartmann K, Fischer J, Gerber AC. Video-intuboscopic assistance is a useful aid to tracheal intubaton in pediatric patients. Can J Anaesth 2001; 48: 691-6
    • (2001) Can. J. Anaesth. , vol.48 , pp. 691-696
    • Weiss, M.1    Hartmann, K.2    Fischer, J.3    Gerber, A.C.4
  • 36
    • 0030780894 scopus 로고    scopus 로고
    • Management of difficult tracheal intubation with a video-optically modified Schroeder intubation stylet
    • Weiss M. Management of difficult tracheal intubation with a video-optically modified Schroeder intubation stylet. Anesth Analg 1997; 85: 1181-2
    • (1997) Anesth. Analg. , vol.85 , pp. 1181-1182
    • Weiss, M.1
  • 37
    • 0033769145 scopus 로고    scopus 로고
    • Difficult airway management: Comparison of the Bullard laryngoscope with the video-optical intubation stylet
    • Weiss M, Schwarz U, Gerber A. Difficult airway management: comparison of the Bullard laryngoscope with the video-optical intubation stylet. Can J Anaesth 2000; 47: 280-4
    • (2000) Can. J. Anaesth. , vol.47 , pp. 280-284
    • Weiss, M.1    Schwarz, U.2    Gerber, A.3
  • 38
    • 24444439919 scopus 로고    scopus 로고
    • The pediatric video-optical intubation stylet
    • Weiss M. The pediatric video-optical intubation stylet. Internet J Anesthesiol 1998; 2N4 http://www.ispub.com/journals/IJA/Vol2N4/vois.htm
    • (1998) Internet J. Anesthesiol.
    • Weiss, M.1
  • 39
    • 0031893799 scopus 로고    scopus 로고
    • Video-intuboscopy: A new aid to routine and difficult tracheal intubation
    • Weiss M. Video-intuboscopy: A new aid to routine and difficult tracheal intubation. Br J Anaesth 1998; 80: 525-7
    • (1998) Br. J. Anaesth. , vol.80 , pp. 525-527
    • Weiss, M.1
  • 40
    • 0019388848 scopus 로고
    • An introduction to the fiberoptic laryngoscope
    • Witton TH. An introduction to the fiberoptic laryngoscope. Can Anaesth Soc J 1981; 28: 475
    • (1981) Can. Anaesth. Soc. J. , vol.28 , pp. 475
    • Witton, T.H.1
  • 41
    • 0034797510 scopus 로고    scopus 로고
    • Use of the intubating laryngeal mask in children: An evaluation using video-endoscopic monitoring
    • Weiss M, Schwarz U, Dillier C, Fischer J, Gerber A. Use of the intubating laryngeal mask in children: an evaluation using video-endoscopic monitoring. Eur J Anaesth 2001; 18: 739-44
    • (2001) Eur. J. Anaesth. , vol.18 , pp. 739-744
    • Weiss, M.1    Schwarz, U.2    Dillier, C.3    Fischer, J.4    Gerber, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.