메뉴 건너뛰기




Volumn 5368, Issue 1, 2004, Pages 79-88

Can a fourier-based cascaded-systems analysis describe noise in complex shift-variant spatially sampled detectors?

Author keywords

Cascaded models; Detective quantum efficiency; Flat panel detectors; Noise power spectrum

Indexed keywords

FOURIER TRANSFORMS; MEDICAL IMAGING; MONTE CARLO METHODS; OPTICAL TRANSFER FUNCTION; PHOTODETECTORS; SIGNAL TO NOISE RATIO;

EID: 3042544892     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.534791     Document Type: Conference Paper
Times cited : (11)

References (14)
  • 4
    • 0000356133 scopus 로고    scopus 로고
    • Signal-to-noise optimization of medical imaging systems
    • I. A. Cunningham and R. Shaw. Signal-to-noise optimization of medical imaging systems. J Opt Soc Am A, 16(3), 1999.
    • (1999) J Opt Soc Am A , vol.16 , Issue.3
    • Cunningham, I.A.1    Shaw, R.2
  • 6
    • 0028921566 scopus 로고
    • Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems
    • J. T. Dobbins. Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems. Med Phys, 22, 1995.
    • (1995) Med Phys , vol.22
    • Dobbins, J.T.1
  • 9
    • 0018575636 scopus 로고
    • Transfer function analysis of radiographic imaging systems
    • C. E. Metz and K. Doi. Transfer function analysis of radiographic imaging systems. Phys Med Biol, 24, 1979.
    • (1979) Phys Med Biol , vol.24
    • Metz, C.E.1    Doi, K.2
  • 12
    • 0003089516 scopus 로고
    • Measurement of the modulation transfer function of radiographic systems containing fluoroscent screens
    • K. Rossmann. Measurement of the modulation transfer function of radiographic systems containing fluoroscent screens. Phys Med Biol, 9, 1964.
    • (1964) Phys Med Biol , vol.9
    • Rossmann, K.1
  • 13
    • 0014238946 scopus 로고
    • The spatial frequency spectrum: A means for studying the quality of radiographic imaging systems
    • K. Rossmann. The spatial frequency spectrum: A means for studying the quality of radiographic imaging systems. Radiology, 90, 1968.
    • (1968) Radiology , vol.90
    • Rossmann, K.1
  • 14
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled mtf of digital radiographic systems using an edge test device
    • Samei.E, M. Flynn, and D. A. Reimann. A method for measuring the presampled mtf of digital radiographic systems using an edge test device. Med Phys, 25(1), 1998.
    • (1998) Med Phys , vol.25 , Issue.1
    • Samei, E.1    Flynn, M.2    Reimann, D.A.3