메뉴 건너뛰기




Volumn 32, Issue 6, 2008, Pages 409-416

Noise in magnitude magnetic resonance images

Author keywords

Gaussian distribution; Magnitude image formation; Noise; Rayleigh distribution; Rician distribution

Indexed keywords


EID: 56749102812     PISSN: 15466086     EISSN: 15525023     Source Type: Journal    
DOI: 10.1002/cmr.a.20124     Document Type: Review
Times cited : (54)

References (20)
  • 2
    • 0021948756 scopus 로고    scopus 로고
    • Henkelman RM. 1986. Measurement of signal intensities in the presence of noise in MR images. Med Phys 12:232-233. Erratum in 1986;13:544.
    • Henkelman RM. 1986. Measurement of signal intensities in the presence of noise in MR images. Med Phys 12:232-233. Erratum in 1986;13:544.
  • 3
    • 0028839871 scopus 로고    scopus 로고
    • Gudbjartsson H, Patz S. 1995. The Rician distribution of noisy MRI data. Magn Reson Med 34:910-914. Erratum in Magn Reson Med 1996;36(2):332-333.
    • Gudbjartsson H, Patz S. 1995. The Rician distribution of noisy MRI data. Magn Reson Med 34:910-914. Erratum in Magn Reson Med 1996;36(2):332-333.
  • 6
    • 0024394344 scopus 로고
    • Improved detectability in low signal-to-noise ratio magnetic resonance images by means of a phase-corrected real reconstruction
    • Bernstein MA, Thomasson DM, Perman WH. 1989. Improved detectability in low signal-to-noise ratio magnetic resonance images by means of a phase-corrected real reconstruction. Med Phys 16:813-817.
    • (1989) Med Phys , vol.16 , pp. 813-817
    • Bernstein, M.A.1    Thomasson, D.M.2    Perman, W.H.3
  • 7
    • 84939730902 scopus 로고
    • Mathematical analysis of random noise
    • Rice SO. 1944. Mathematical analysis of random noise. Bell Syst Technol J 23:282-332.
    • (1944) Bell Syst Technol J , vol.23 , pp. 282-332
    • Rice, S.O.1
  • 8
    • 0030015095 scopus 로고    scopus 로고
    • Analysis of noise in phase contrast MR imaging
    • Andersen AH, Kirsch JE. 1996. Analysis of noise in phase contrast MR imaging. Med Phys 23:857-869.
    • (1996) Med Phys , vol.23 , pp. 857-869
    • Andersen, A.H.1    Kirsch, J.E.2
  • 9
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • Constantinides CD, Atalar E, McVeigh ER. 1997. Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 38:852-857.
    • (1997) Magn Reson Med , vol.38 , pp. 852-857
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 10
    • 0021254150 scopus 로고
    • A signal-to-noise calibration procedure for NMR imaging systems
    • Edelstein WA, Bottomley PA, Pfeifer LM. 1984. A signal-to-noise calibration procedure for NMR imaging systems. Med Phys 11:180-185.
    • (1984) Med Phys , vol.11 , pp. 180-185
    • Edelstein, W.A.1    Bottomley, P.A.2    Pfeifer, L.M.3
  • 11
    • 0027453763 scopus 로고
    • The use of power images to perform quantitative analysis on low SNR MR images
    • Miller AJ, Joseph PM. 1993. The use of power images to perform quantitative analysis on low SNR MR images. Magn Reson Imag 11:1051-1056.
    • (1993) Magn Reson Imag , vol.11 , pp. 1051-1056
    • Miller, A.J.1    Joseph, P.M.2
  • 12
    • 33645875326 scopus 로고    scopus 로고
    • Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
    • Koay CG, Basser PJ. 2006. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson 179:317-322.
    • (2006) J Magn Reson , vol.179 , pp. 317-322
    • Koay, C.G.1    Basser, P.J.2
  • 14
    • 7544247899 scopus 로고    scopus 로고
    • Squashing peanuts and smashing pumpkins: How noise distorts diffusion weighted MR data
    • Jones DK, Basser PJ. 2004. "Squashing peanuts and smashing pumpkins": How noise distorts diffusion weighted MR data. Magn Reson Med 52:979-993.
    • (2004) Magn Reson Med , vol.52 , pp. 979-993
    • Jones, D.K.1    Basser, P.J.2
  • 15
    • 34247196111 scopus 로고    scopus 로고
    • Automatic estimation of the noise variance from the histogram of a magnetic resonance image
    • Sijbers J, Poot D, Dekker AJ, Pintjens W. 2007. Automatic estimation of the noise variance from the histogram of a magnetic resonance image. Phys Med Biol 52:1335-1348.
    • (2007) Phys Med Biol , vol.52 , pp. 1335-1348
    • Sijbers, J.1    Poot, D.2    Dekker, A.J.3    Pintjens, W.4
  • 16
    • 0030203110 scopus 로고    scopus 로고
    • On the rician distribution of noisy MRI data
    • Andersen AH. 1996. On the rician distribution of noisy MRI data. Magn Reson Med 36:331-333.
    • (1996) Magn Reson Med , vol.36 , pp. 331-333
    • Andersen, A.H.1
  • 17
    • 0028865810 scopus 로고
    • Multiple Breat-hold averaging (MBA) method for increasing SNR in abdominal MRI
    • Feinberg DA, Rofsky NM, Johnson G. 1995. Multiple Breat-hold averaging (MBA) method for increasing SNR in abdominal MRI. Magn Reson Med 34:905-909.
    • (1995) Magn Reson Med , vol.34 , pp. 905-909
    • Feinberg, D.A.1    Rofsky, N.M.2    Johnson, G.3
  • 20
    • 56749126190 scopus 로고    scopus 로고
    • Normal Sum Distributions, http://mathworld.wolfram.com/ NormalSumDistribution.html. June 4, 2008.
    • Normal Sum Distributions, http://mathworld.wolfram.com/ NormalSumDistribution.html. June 4, 2008.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.