메뉴 건너뛰기




Volumn 22, Issue 5, 2008, Pages 361-366

Reliability of cardiac output calculation by the fick principle and central venous oxygen saturation in emergency conditions

Author keywords

Cardiac output; Fick; Scvo2; Svo2; Thermodilution

Indexed keywords

FLUORESCENT SCREENS; HOSPITALS; INTENSIVE CARE UNITS; OXYGEN;

EID: 56749096581     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-008-9143-y     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 0035829842 scopus 로고    scopus 로고
    • Early Goal-Directed Therapy Collaborative Group. Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M, Early Goal-Directed Therapy Collaborative Group. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345: 1368-77.
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3    Ressler, J.4    Muzzin, A.5    Knoblich, B.6    Peterson, E.7    Tomlanovich, M.8
  • 2
    • 0015041424 scopus 로고
    • A new technique for measurement of cardiac output by thermodilution in man
    • Ganz W, Donoso R, Marcus HS, Forrester JS, Swan HJ. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol. 1971; 27: 392-396.
    • (1971) Am J Cardiol. , vol.27 , pp. 392-396
    • Ganz, W.1    Donoso, R.2    Marcus, H.S.3    Forrester, J.S.4    Swan, H.J.5
  • 3
    • 0023493373 scopus 로고
    • A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction
    • Gore JM, Goldberg RJ, Spodick DH, Alpert JS, Dalen JE: A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction. Chest 1987; 92: 721-727.
    • (1987) Chest , vol.92 , pp. 721-727
    • Gore, J.M.1    Goldberg, R.J.2    Spodick, D.H.3    Alpert, J.S.4    Dalen, J.E.5
  • 5
    • 0036222048 scopus 로고    scopus 로고
    • Cardiac output measurement by pulse dye densitometry: A comparison with the Fick's principle and thermodilution method
    • Bremer F, Schiele A, Tschaikowsky K Cardiac output measurement by pulse dye densitometry: A comparison with the Fick's principle and thermodilution method. Intensive Care Med 2002; 28: 399-405.
    • (2002) Intensive Care Med , vol.28 , pp. 399-405
    • Bremer, F.1    Schiele, A.2    Tschaikowsky, K.3
  • 6
    • 12144256186 scopus 로고    scopus 로고
    • Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method
    • Engoren M, Barbee D: Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method. Am J Crit Care. 2005; 14: 40-5.
    • (2005) Am J Crit Care , vol.14 , pp. 40-45
    • Engoren, M.1    Barbee, D.2
  • 7
    • 0242575195 scopus 로고    scopus 로고
    • Increased risk associated with pulmonary artery catheterization in the medical intensive care unit
    • Peters SG, Afessa B, Decker PA, Schroeder DR, Offord KP, Scott JP: Increased risk associated with pulmonary artery catheterization in the medical intensive care unit. J Crit Care 2003; 18: 166-71.
    • (2003) J Crit Care , vol.18 , pp. 166-171
    • Peters, S.G.1    Afessa, B.2    Decker, P.A.3    Schroeder, D.R.4    Offord, K.P.5    Scott, J.P.6
  • 8
    • 0029795650 scopus 로고    scopus 로고
    • Swan song for the Swan-Ganz catheter?
    • Soni N (1996) Swan song for the Swan-Ganz catheter? BMJ 313: 763-764.
    • (1996) BMJ , vol.313 , pp. 763-764
    • Soni, N.1
  • 10
    • 23044442783 scopus 로고    scopus 로고
    • Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions
    • Dueck MH, Klimek M, Appenrodt S, Weigand C, Boerner U: Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005; 103: 249-57.
    • (2005) Anesthesiology , vol.103 , pp. 249-257
    • Dueck, M.H.1    Klimek, M.2    Appenrodt, S.3    Weigand, C.4    Boerner, U.5
  • 12
    • 4143058000 scopus 로고    scopus 로고
    • Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
    • Reinhart K, Kuhn HJ, Hartog C, Bredle DL: Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Med 2004; 30: 1572-8.
    • (2004) Intensive Care Med , vol.30 , pp. 1572-1578
    • Reinhart, K.1    Kuhn, H.J.2    Hartog, C.3    Bredle, D.L.4
  • 13
    • 33746414431 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and Fick methods in the measurement of cardiac output
    • Baylor P: Lack of agreement between thermodilution and Fick methods in the measurement of cardiac output. J Intensive Care Medicine 2006; 21: 93-8.
    • (2006) J Intensive Care Medicine , vol.21 , pp. 93-98
    • Baylor, P.1
  • 14
    • 0031007060 scopus 로고    scopus 로고
    • Comparison of indirect calorimetry and thermodilution cardiac output measurement in children
    • Capderou A, Douguet D, Losay J, Zelter M: Comparison of indirect calorimetry and thermodilution cardiac output measurement in children. Am J Respir Crit Care Med 1997; 155: 1930-4.
    • (1997) Am J Respir Crit Care Med , vol.155 , pp. 1930-1934
    • Capderou, A.1    Douguet, D.2    Losay, J.3    Zelter, M.4
  • 15
    • 0027447134 scopus 로고
    • Errors in the measurement of cardiac output by thermodilution
    • Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993; 40: 142-53.
    • (1993) Can J Anaesth , vol.40 , pp. 142-153
    • Nishikawa, T.1    Dohi, S.2
  • 16
    • 0020445597 scopus 로고
    • Reliability of thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, Raffin TA: Reliability of thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982; 126: 1001-4.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 17
    • 0027303341 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients
    • Sageman WS, Amundson DE: Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients. Crit Care Med 1993; 21: 1139-42.
    • (1993) Crit Care Med , vol.21 , pp. 1139-1142
    • Sageman, W.S.1    Amundson, D.E.2
  • 18
    • 16844383074 scopus 로고    scopus 로고
    • Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock
    • Marx G, Schuerholz T, Sumpelmann R, Simon T, Leuwer M: Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock. Eur J Anaesthesiol 2005; 22: 129-34.
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 129-134
    • Marx, G.1    Schuerholz, T.2    Sumpelmann, R.3    Simon, T.4    Leuwer, M.5
  • 20
    • 0024337859 scopus 로고
    • Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand
    • Reinhart K, Rudolph T, Bredle DL, Hannemann L, Cain SM: Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand. Chest 1989; 95: 1216-21.
    • (1989) Chest , vol.95 , pp. 1216-1221
    • Reinhart, K.1    Rudolph, T.2    Bredle, D.L.3    Hannemann, L.4    Cain, S.M.5
  • 21
    • 0015334492 scopus 로고
    • Central venous oxygen saturation in shock: A study in man
    • Lee J, Wright F, Barber R, Stanley L: Central venous oxygen saturation in shock: A study in man. Anesthesiology 1972; 36: 472-8.
    • (1972) Anesthesiology , vol.36 , pp. 472-478
    • Lee, J.1    Wright, F.2    Barber, R.3    Stanley, L.4
  • 22
    • 10444279213 scopus 로고    scopus 로고
    • Lack of equivalence between central and mixed venous oxygen saturation
    • Chawla LS, Zia H, Gutierrez G, Katz NM, Seneff MG, Shah M: Lack of equivalence between central and mixed venous oxygen saturation. Chest 2004; 126: 1891-6.
    • (2004) Chest , vol.126 , pp. 1891-1896
    • Chawla, L.S.1    Zia, H.2    Gutierrez, G.3    Katz, N.M.4    Seneff, M.G.5    Shah, M.6