메뉴 건너뛰기




Volumn 5370 III, Issue , 2004, Pages 1486-1497

Algorithmic solutions for live device-to-vessel match

Author keywords

Angiogram; Image guided intervention; Multimodality registration; Navigation support; Real time image processing

Indexed keywords

ALGORITHMS; ANGIOGRAPHY; ANISOTROPY; CARDIOVASCULAR SYSTEM; DIFFUSION; OPTICAL FILTERS; REAL TIME SYSTEMS; STAMPING;

EID: 5644269105     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.534076     Document Type: Conference Paper
Times cited : (7)

References (23)
  • 1
    • 0141954914 scopus 로고    scopus 로고
    • Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature
    • S. A. M. Baert, E. B. van de Kraats, T. van Walsum, M. A. Viergever, and W. J. Niessen, "Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature," IEEE Trans. Medical Imaging 22(10), pp. 1252-1258, 2003.
    • (2003) IEEE Trans. Medical Imaging , vol.22 , Issue.10 , pp. 1252-1258
    • Baert, S.A.M.1    Van De Kraats, E.B.2    Van Walsum, T.3    Viergever, M.A.4    Niessen, W.J.5
  • 3
    • 0036770219 scopus 로고    scopus 로고
    • Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography Based on 3-D image registration
    • D. Manke, P. Rösch, K. Nehrke, P. Börnert, and Olaf Dössel, "Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography Based on 3-D image registration," IEEE Trans. Medical Imaging 21(9), pp. 1132-1141, 2002.
    • (2002) IEEE Trans. Medical Imaging , vol.21 , Issue.9 , pp. 1132-1141
    • Manke, D.1    Rösch, P.2    Nehrke, K.3    Börnert, P.4    Dössel, O.5
  • 5
    • 0032008619 scopus 로고    scopus 로고
    • A survey of medical image registration
    • J. B. A. Maintz and M. A. Viergever, "A survey of medical image registration," Medical Image Analysis 2(1), pp. 1-37, 1998.
    • (1998) Medical Image Analysis , vol.2 , Issue.1 , pp. 1-37
    • Maintz, J.B.A.1    Viergever, M.A.2
  • 6
    • 0012570268 scopus 로고    scopus 로고
    • Texture-adaptive active contour models
    • S. Singh, N. A. Murshed, and W. G. Kropatsch, eds., Proc. LNCS 2013
    • T. M. Lehmann, J. Bredno, and K. Spitzer, "Texture-adaptive active contour models," in Advances in Pattern Recognition - ICAPR 2001, S. Singh, N. A. Murshed, and W. G. Kropatsch, eds., Proc. LNCS 2013, pp. 387-396, 2001.
    • (2001) Advances in Pattern Recognition - ICAPR 2001 , pp. 387-396
    • Lehmann, T.M.1    Bredno, J.2    Spitzer, K.3
  • 7
    • 5644223567 scopus 로고    scopus 로고
    • Statistical-model based identification of complete vessel-tree frames in coronary angiograms
    • C. A. Bouman and E. L. Miller, eds., Proc. SPIE to appear
    • A. Condurache, K. Eck, J. Bredno, and T. Aach, "Statistical-model based identification of complete vessel-tree frames in coronary angiograms," in Electronic Imaging: Computational Imaging, C. A. Bouman and E. L. Miller, eds., Proc. SPIE 5299, 2004, to appear.
    • (2004) Electronic Imaging: Computational Imaging , vol.5299
    • Condurache, A.1    Eck, K.2    Bredno, J.3    Aach, T.4
  • 8
    • 5644257429 scopus 로고    scopus 로고
    • Synthesis of angiographic images using iterative approximation
    • J. M. Fitzpatrick and M. Sonka, eds., Proc. SPIE to appear
    • K. Eck, I. Wächter, and J. Bredno, "Synthesis of angiographic images using iterative approximation," in Medical Imaging: Image Processing, J. M. Fitzpatrick and M. Sonka, eds., Proc. SPIE 5370, 2004, to appear.
    • (2004) Medical Imaging: Image Processing , vol.5370
    • Eck, K.1    Wächter, I.2    Bredno, J.3
  • 9
    • 5644223566 scopus 로고    scopus 로고
    • Mutual information based respiration detection
    • H. U. Lemke and M. W. Vannier, eds., Exerpta Medica International Congress Series
    • B. Martín-Leung, K. Eck, I. Stuke, J. Bredno, and T. Aach, "Mutual information based respiration detection," in Computer Assisted Radiology and Surgery (CARS 2003), H. U. Lemke and M. W. Vannier, eds., Exerpta Medica International Congress Series 1256, pp. 1085-1092, 2003.
    • (2003) Computer Assisted Radiology and Surgery (CARS 2003) , vol.1256 , pp. 1085-1092
    • Martín-Leung, B.1    Eck, K.2    Stuke, I.3    Bredno, J.4    Aach, T.5
  • 10
    • 0024628763 scopus 로고
    • Automated identification of vessel contours in coronary arteriograms
    • Y. Sun, "Automated identification of vessel contours in coronary arteriograms," IEEE Trans. Medical Imaging 8(1), pp. 78-88, 1989.
    • (1989) IEEE Trans. Medical Imaging , vol.8 , Issue.1 , pp. 78-88
    • Sun, Y.1
  • 14
    • 0031031673 scopus 로고    scopus 로고
    • An algorithm for real time vessel enhancement and detection
    • R. Poli and G. Valli, "An algorithm for real time vessel enhancement and detection," Computer methods and programs in biomedicine 52(1), pp. 1-22, 1996.
    • (1996) Computer Methods and Programs in Biomedicine , vol.52 , Issue.1 , pp. 1-22
    • Poli, R.1    Valli, G.2
  • 15
    • 0036028246 scopus 로고    scopus 로고
    • Spatiotemporal multiscale vessel enhancement for coronary angiograms
    • M. Sonka and J. M. Fitzpatrick, eds., Proc. SPIE
    • T. Aach, C. Mayntz, P. Rongen, G. Schmitz, and H. Stegehuis, "Spatiotemporal multiscale vessel enhancement for coronary angiograms," in in Medical Imaging: Image Processing, M. Sonka and J. M. Fitzpatrick, eds., Proc. SPIE, 4684, pp. 1010-1021, 2002.
    • (2002) Medical Imaging: Image Processing , vol.4684 , pp. 1010-1021
    • Aach, T.1    Mayntz, C.2    Rongen, P.3    Schmitz, G.4    Stegehuis, H.5
  • 18
    • 0041419402 scopus 로고    scopus 로고
    • 3D vessel axis extraction using 2D calibrated x-ray projections for coronary modeling
    • M. Sonka and J. M. Fitzpatrick, eds., Proc. SPIE
    • S. Young, B. Movassaghi, J. Weese, and V. Rasche, "3D vessel axis extraction using 2D calibrated x-ray projections for coronary modeling," in Medical Imaging: Image Processing, M. Sonka and J. M. Fitzpatrick, eds., Proc. SPIE 5032, pp. 1491-1498, 2003.
    • (2003) Medical Imaging: Image Processing , vol.5032 , pp. 1491-1498
    • Young, S.1    Movassaghi, B.2    Weese, J.3    Rasche, V.4
  • 19
    • 0032912122 scopus 로고    scopus 로고
    • Quantitative evaluation of vessel tracking techniques on coronary angiograms
    • A. Sen, L. Lan, K. Doi, and K. R. Hoffmann, "Quantitative evaluation of vessel tracking techniques on coronary angiograms," Medical Physics 26(5), pp. 698-706, 1999.
    • (1999) Medical Physics , vol.26 , Issue.5 , pp. 698-706
    • Sen, A.1    Lan, L.2    Doi, K.3    Hoffmann, K.R.4
  • 21
    • 0036890672 scopus 로고    scopus 로고
    • Vascular tree object segmentation by deskeletonization of valley courses
    • Z. Chen and S. Molloi, "Vascular tree object segmentation by deskeletonization of valley courses," Computerized Medical Imaging and Graphics 26, pp. 419-428, 2002.
    • (2002) Computerized Medical Imaging and Graphics , vol.26 , pp. 419-428
    • Chen, Z.1    Molloi, S.2
  • 22
    • 0036999895 scopus 로고    scopus 로고
    • Validation of medical image processing in image-guided therapy
    • "Validation of medical image processing in image-guided therapy," Editorial, IEEE Trans. Medical Imaging 21(12), pp. 1445-1449, 2002.
    • (2002) IEEE Trans. Medical Imaging , vol.21 , Issue.12 , pp. 1445-1449
  • 23
    • 8844220419 scopus 로고    scopus 로고
    • Software architecture for live enhancement of medical images
    • N. Kehtarnavaz and P. A. Laplante, eds., Proc. SPIE to appear
    • J. Bredno, B. Martín-Leung, and K. Eck, "Software architecture for live enhancement of medical images," in Electronic Imaging: Real-Time Imaging, N. Kehtarnavaz and P. A. Laplante, eds., Proc. SPIE 5297, 2004, to appear.
    • (2004) Electronic Imaging: Real-Time Imaging , vol.5297
    • Bredno, J.1    Martín-Leung, B.2    Eck, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.