-
1
-
-
0025172902
-
Studying single living cells and chromosomes by confocal Raman microspectroscopy
-
G. J. Puppels, et al., "Studying single living cells and chromosomes by confocal Raman microspectroscopy," Nature 347, 301-303 (1990).
-
(1990)
Nature
, vol.347
, pp. 301-303
-
-
Puppels, G.J.1
-
2
-
-
0001104529
-
Three dimensional vibrational imaging by coherent anti-Stokes Raman scattering
-
A. Zumbusch, et al., "Three dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
-
(1999)
Phys. Rev. Lett.
, vol.82
, pp. 4142-4145
-
-
Zumbusch, A.1
-
3
-
-
0033950947
-
CARS microscopy with folded BoxCARS phasematching
-
M. Müller, et al., "CARS microscopy with folded BoxCARS phasematching," J. Microsc. 197, 150-158 (2000).
-
(2000)
J. Microsc.
, vol.197
, pp. 150-158
-
-
Müller, M.1
-
4
-
-
37149021669
-
Vibrational imaging with high sensitivity via epidetected coherent anti-Stokes Raman scattering microscopy
-
A. Volkmer, et al., "Vibrational imaging with high sensitivity via epidetected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 23901-1/4 (2001).
-
(2001)
Phys. Rev. Lett.
, vol.87
-
-
Volkmer, A.1
-
5
-
-
0000422977
-
Polarization coherent anti-Stokes Raman scattering microscopy
-
J. Cheng, et al., "Polarization coherent anti-Stokes Raman scattering microscopy," Opt. Lett. 26, 1341-1343 (2001).
-
(2001)
Opt. Lett.
, vol.26
, pp. 1341-1343
-
-
Cheng, J.1
-
6
-
-
0037062001
-
Imaging the thermodynamic state of lipid membranes with multiplex CARS microscopy
-
M. Müller, et al., "Imaging the thermodynamic state of lipid membranes with multiplex CARS microscopy," J. Phys. Chem. B 106, 3715-3723 (2002).
-
(2002)
J. Phys. Chem. B
, vol.106
, pp. 3715-3723
-
-
Müller, M.1
-
7
-
-
0036642294
-
Chemical specificity in 3D imaging with multiplex CARS microscopy
-
G. W. H. Wurpel, et al., "Chemical specificity in 3D imaging with multiplex CARS microscopy," Opt. Lett. 27, 1093-1095 (2002).
-
(2002)
Opt. Lett.
, vol.27
, pp. 1093-1095
-
-
Wurpel, G.W.H.1
-
8
-
-
79956020247
-
Time-resolved coherent anti-Stokes Raman scattering microscopy: Imaging based on Raman free induction decay
-
A. Volkmer, et al., "Time-resolved coherent anti-Stokes Raman scattering microscopy: imaging based on Raman free induction decay," Appl. Phys. Lett. 80, 1505-1507 (2002).
-
(2002)
Appl. Phys. Lett.
, vol.80
, pp. 1505-1507
-
-
Volkmer, A.1
-
9
-
-
0037136757
-
Coherent anti-Stokes Raman scattering correlation spectroscopy: Probing dynamical processes with chemical specificity
-
J. Cheng, et al., "Coherent anti-Stokes Raman scattering correlation spectroscopy: Probing dynamical processes with chemical specificity," J. Phys. Chem. A 106, 8561-8568 (2002).
-
(2002)
J. Phys. Chem. A
, vol.106
, pp. 8561-8568
-
-
Cheng, J.1
-
10
-
-
0021196548
-
(3)) - Perturbative and diagrammatic approaches
-
(3)) - Perturbative and diagrammatic approaches," IEEE J. Quant. Electr. 20, 37-42 (1984).
-
(1984)
IEEE J. Quant. Electr.
, vol.20
, pp. 37-42
-
-
Prior, Y.1
-
12
-
-
5644237491
-
Direct measurement of chain order in single lipid mono- And bilayers with multiplex CARS
-
G. W. H. Wurpel, et al., "Direct measurement of chain order in single lipid mono- and bilayers with multiplex CARS," J. Phys. Chem. B (2003).
-
(2003)
J. Phys. Chem. B
-
-
Wurpel, G.W.H.1
-
13
-
-
0001478094
-
Polarization active Raman spectroscopy and coherent Raman elipsometry
-
S. A. Akhmanov, et al., "Polarization active Raman spectroscopy and coherent Raman elipsometry," Sov. Phys. JETP 47, 667-678 (1978).
-
(1978)
Sov. Phys. JETP
, vol.47
, pp. 667-678
-
-
Akhmanov, S.A.1
-
14
-
-
0035249710
-
An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity
-
J. Cheng, et al., "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
-
(2001)
J. Phys. Chem. B
, vol.105
, pp. 1277-1280
-
-
Cheng, J.1
-
15
-
-
0038115136
-
Femtosecond phase-and-polarization control for background-free coherent anti-stokes Raman spectroscopy
-
D. Oron, et al., "Femtosecond Phase-and-Polarization Control for Background-Free Coherent Anti-Stokes Raman Spectroscopy," Phys. Rev. Lett. 90, 213902 (2003).
-
(2003)
Phys. Rev. Lett.
, vol.90
, pp. 213902
-
-
Oron, D.1
|