Volumn 14, Issue 5, 1999, Pages 681-688

Measuring abutment/implant joint integrity with the periotest instrument

Author keywords

Abutment screw; Abutment screw loosening; Abutment implant interface; Periotest; Periotest value; Tensile preload

Indexed keywords

ARTICLE; DENTAL SURGERY; DENTURE; HUMAN; INSTRUMENTATION; MATERIALS TESTING; MECHANICAL STRESS; MOUTH DISEASE; PERCUSSION; SENSITIVITY AND SPECIFICITY; SURFACE PROPERTY; TENSILE STRENGTH; TOOTH IMPLANTATION; TORQUE;

EID: 0033197316     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (8)
  • 1
    • 0025388816 scopus 로고
    • Periotest: A dynamic procedure for the diagnosis of the human periodontium
    • Lukas D, Schulte W. Periotest: A dynamic procedure for the diagnosis of the human periodontium. Clin Phys Physiol Meas 1990;11: 6575.
    • (1990) Clin Phys Physiol Meas , vol.11 , pp. 65-75
    • Lukas, D.1    Schulte, W.2
  • 2
    • 0025654203 scopus 로고
    • The Periotest method as a measure of osseointegrated oral implant stability
    • Olive J, Aparicio C. The Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 1990;5: 390400.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 390-400
    • Olive, J.1    Aparicio, C.2
  • 3
    • 0029266570 scopus 로고
    • Assessment of the Periotest device in baseline mobility measurements of craniofacial implants
    • Derhami K, Wolfaardt JF, Faulkner G, Grace M. Assessment of the Periotest device in baseline mobility measurements of craniofacial implants. Int J Oral Maxillofac Implants 1995;10: 221229.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 221-229
    • Derhami, K.1    Wolfaardt, J.F.2    Faulkner, G.3    Grace, M.4
  • 5
    • 0030280566 scopus 로고    scopus 로고
    • A dynamic modal testing technique for non-invasive assessment of bone-dental implant interfaces
    • Elias J, Brunski JB, Scarton HA. A dynamic modal testing technique for non-invasive assessment of bone-dental implant interfaces. Int J Oral Maxillofac Implants 1996;11: 728734.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 728-734
    • Elias, J.1    Brunski, J.B.2    Scarton, H.A.3
  • 7
    • 0027594980 scopus 로고
    • Dynamics of the Periotest method for diagnosing the dental implant-bone interface
    • Kaneko TM. Dynamics of the Periotest method for diagnosing the dental implant-bone interface. J Mater Sci Mater Med 1993;4: 256259.
    • (1993) J Mater Sci Mater Med , vol.4 , pp. 256-259
    • Kaneko, T.M.1
  • 8
    • 0031255467 scopus 로고    scopus 로고
    • Theoretical study of the effects of tooth and implant mobility differences on occlusal force transmission in tooth/implant supported partial prostheses
    • Kayacan R, Ballarini R, Mullen RL. Theoretical study of the effects of tooth and implant mobility differences on occlusal force transmission in tooth/implant supported partial prostheses. J Prosthet Dent 1997;78: 391399.
    • (1997) J Prosthet Dent , vol.78 , pp. 391-399
    • Kayacan, R.1    Ballarini, R.2    Mullen, R.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.