메뉴 건너뛰기




Volumn 47, Issue 5, 2003, Pages 622-625

Bronchial rupture with a left-sided polyvinylchloride double-lumen tube

Author keywords

Complications; Double lumen tubes; Intubation endobronchial

Indexed keywords

FENTANYL; ISOFLURANE; MIDAZOLAM; POLYVINYLCHLORIDE; THIOPENTAL; VECURONIUM;

EID: 0038298791     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-6576.2003.00102.x     Document Type: Article
Times cited : (56)

References (13)
  • 2
    • 0032995477 scopus 로고    scopus 로고
    • Bronchial rupture by a double-lumen endobronchial tube during staging thoracoscopy
    • Gilbert TB, Goodsell CW, Krasna MJ. Bronchial rupture by a double-lumen endobronchial tube during staging thoracoscopy. Anesth Analg 1999; 88: 1252-3.
    • (1999) Anesth Analg , vol.88 , pp. 1252-1253
    • Gilbert, T.B.1    Goodsell, C.W.2    Krasna, M.J.3
  • 3
    • 0032242584 scopus 로고    scopus 로고
    • Iatrogenic rupture of the left mainstem bronchus in tracheobronchial intubation
    • Del Corso B, Tanaskovic G, Mastropasqua D, Luzzani A. Iatrogenic rupture of the left mainstem bronchus in tracheobronchial intubation. Minerva Anesthesiol 1998; 64: 581-5.
    • (1998) Minerva Anesthesiol , vol.64 , pp. 581-585
    • Del Corso, B.1    Tanaskovic, G.2    Mastropasqua, D.3    Luzzani, A.4
  • 5
    • 0024428657 scopus 로고
    • Bronchial rupture associated with the use of adouble-lumen tube in a small adult
    • Hannallah M, Gomes M. Bronchial rupture associated with the use of adouble-lumen tube in a small adult. Anesthesiology 1989; 71: 457-9.
    • (1989) Anesthesiology , vol.71 , pp. 457-459
    • Hannallah, M.1    Gomes, M.2
  • 6
    • 0031807844 scopus 로고    scopus 로고
    • Predicting the size of a double-lumen endobronchial tube based on tracheal diameter
    • Chow MYH, Liam BL, Thomas LW, Chelliah RY, Ong BC. Predicting the size of a double-lumen endobronchial tube based on tracheal diameter. Anesth Analg 1998; 87: 158-60.
    • (1998) Anesth Analg , vol.87 , pp. 158-160
    • Chow, M.Y.H.1    Liam, B.L.2    Thomas, L.W.3    Chelliah, R.Y.4    Ong, B.C.5
  • 7
    • 0032909192 scopus 로고    scopus 로고
    • Predicting the size of a double-lumen endobronchial tube using computed tomographic scanmeasurements of the left main bronchus diameter
    • Chow MY, Liam BL, Thng CH, Chong BK. Predicting the size of a double-lumen endobronchial tube using computed tomographic scanmeasurements of the left main bronchus diameter. Anesth Analg 1999; 88: 302-5.
    • (1999) Anesth Analg , vol.88 , pp. 302-305
    • Chow, M.Y.1    Liam, B.L.2    Thng, C.H.3    Chong, B.K.4
  • 8
    • 0032987424 scopus 로고    scopus 로고
    • Placement of left-sided double-lumen endobronchial tubes: Comparison of clinical and fiberoptic-guided placement
    • Cheong KF, Koh KF. Placement of left-sided double-lumen endobronchial tubes: comparison of clinical and fiberoptic-guided placement. BJA 1999; 82: 920-1.
    • (1999) BJA , vol.82 , pp. 920-921
    • Cheong, K.F.1    Koh, K.F.2
  • 10
    • 0028198886 scopus 로고
    • Fiberoptic bronchoscopy should not be a standard of care when positioning double-lumen endobronchial tubes
    • Brodsky JB. Fiberoptic bronchoscopy should not be a standard of care when positioning double-lumen endobronchial tubes (letter). J Cardiothorac Vasc Anesth 1994; 8: 373-5.
    • (1994) J Cardiothorac Vasc Anesth , vol.8 , pp. 373-375
    • Brodsky, J.B.1
  • 12
    • 0024822475 scopus 로고
    • Bronchial cuff pressures of double-lumen tubes
    • Brodsky JB, Adkins MO, Gaba DM. Bronchial cuff pressures of double-lumen tubes. Anesth Analg 1989; 69: 608-10.
    • (1989) Anesth Analg , vol.69 , pp. 608-610
    • Brodsky, J.B.1    Adkins, M.O.2    Gaba, D.M.3
  • 13
    • 0031784633 scopus 로고    scopus 로고
    • A comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus
    • Hannallah MS, Gharagozloo F, Gomes MN, Chase GA. A comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus. Anesth Analg 1998; 87: 1027-31.
    • (1998) Anesth Analg , vol.87 , pp. 1027-1031
    • Hannallah, M.S.1    Gharagozloo, F.2    Gomes, M.N.3    Chase, G.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.