메뉴 건너뛰기




Volumn 5, Issue 1, 2009, Pages 81-94

Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges

Author keywords

Electro mechanical impedance; Modal parameters; Prestress loss; PSC girder; Structural health monitoring; Vibration; Vibration based damage detection

Indexed keywords

CONCRETE BEAMS AND GIRDERS; DAMAGE DETECTION; FORECASTING; FREQUENCY RESPONSE; MODAL ANALYSIS; PRESTRESSED CONCRETE; STRUCTURAL HEALTH MONITORING;

EID: 56049087106     PISSN: 17381584     EISSN: 17381991     Source Type: Journal    
DOI: 10.12989/sss.2009.5.1.081     Document Type: Article
Times cited : (64)

References (30)
  • 1
    • 0017951397 scopus 로고
    • A vibration technique for non-destructively assessing the integrity of structures
    • Adams, R. D., Cawley, P., Pye, C. J. and Stone, B. J. (1978), "A vibration technique for non-destructively assessing the integrity of structures", J. Mech. Eng. Sci., 20, 93-100.
    • (1978) J. Mech. Eng. Sci , vol.20 , pp. 93-100
    • Adams, R.D.1    Cawley, P.2    Pye, C.J.3    Stone, B.J.4
  • 3
    • 0141871974 scopus 로고    scopus 로고
    • Structural impedance based damage diagnosis by piezo-transducers
    • Bhalla, S. and Soh, C. K. (2003), "Structural impedance based damage diagnosis by piezo-transducers", Earthq. Eng. Struct. Dyn., 32(12), 1897-1916.
    • (2003) Earthq. Eng. Struct. Dyn , vol.32 , Issue.12 , pp. 1897-1916
    • Bhalla, S.1    Soh, C.K.2
  • 4
    • 0035361632 scopus 로고    scopus 로고
    • Modal identification of output-only systems using frequency domain decomposition
    • Brinker, R., Zhang, L. and Andersen, P. (2001), "Modal identification of output-only systems using frequency domain decomposition", Smart Mater. Struct., 10, 441-445.
    • (2001) Smart Mater. Struct , vol.10 , pp. 441-445
    • Brinker, R.1    Zhang, L.2    Andersen, P.3
  • 5
    • 0032023438 scopus 로고    scopus 로고
    • A summary review of vibration-based damage identification methods
    • Doebling, S. W., Farrar, C. R. and Prime, M. B. (1998), "A summary review of vibration-based damage identification methods", The Shock Vib. Digest, 30(2), 91-105.
    • (1998) The Shock Vib. Digest , vol.30 , Issue.2 , pp. 91-105
    • Doebling, S.W.1    Farrar, C.R.2    Prime, M.B.3
  • 6
    • 30644466219 scopus 로고    scopus 로고
    • Long-term monitoring of electrically isolated post-tensioning tendons
    • Elsener, B. (2005), "Long-term monitoring of electrically isolated post-tensioning tendons", Struct. Concrete, 6(3), 101-106.
    • (2005) Struct. Concrete , vol.6 , Issue.3 , pp. 101-106
    • Elsener, B.1
  • 7
    • 33745941779 scopus 로고    scopus 로고
    • Damage detection in thin plates and aerospace structures with the electro-mechanical impedance method
    • Giurgiutiu, V. and Zagrai, A. N. (2005), "Damage detection in thin plates and aerospace structures with the electro-mechanical impedance method", Struct. Health Monitor, 4(2), 99-118.
    • (2005) Struct. Health Monitor , vol.4 , Issue.2 , pp. 99-118
    • Giurgiutiu, V.1    Zagrai, A.N.2
  • 8
    • 0242724085 scopus 로고    scopus 로고
    • Structural health monitoring using multiple piezoelectric sensors and actuators
    • Master's thesis, Virginia Polytechnic Institute and State University
    • Kabeya, K. (1998), "Structural health monitoring using multiple piezoelectric sensors and actuators", Master's thesis, Virginia Polytechnic Institute and State University.
    • (1998)
    • Kabeya, K.1
  • 9
    • 56049097422 scopus 로고
    • Improved damage identification method based on modal information
    • Kim, J. T. and Stubbs, N. (1995), "Improved damage identification method based on modal information", J. Sound. Vib., 259(1), 57-67.
    • (1995) J. Sound. Vib , vol.259 , Issue.1 , pp. 57-67
    • Kim, J.T.1    Stubbs, N.2
  • 10
    • 34249727826 scopus 로고    scopus 로고
    • Vibration-based damage monitoring in model plate-girder bridges under uncertain temperature conditions
    • Kim, J. T., Park, J. H. and Lee, B. J. (2007), "Vibration-based damage monitoring in model plate-girder bridges under uncertain temperature conditions", Eng. Struct., 29(7), 263-280.
    • (2007) Eng. Struct , vol.29 , Issue.7 , pp. 263-280
    • Kim, J.T.1    Park, J.H.2    Lee, B.J.3
  • 11
    • 0037210189 scopus 로고    scopus 로고
    • Damage identification in beam-type structures: Frequency-based method vs mode-shape-based method
    • Kim, J. T., Ryu, Y. S., Cho, H. M. and Stubbs, N. (2003a), "Damage identification in beam-type structures: frequency-based method vs mode-shape-based method", Eng. Struct., 25, 57-67.
    • (2003) Eng. Struct , vol.25 , pp. 57-67
    • Kim, J.T.1    Ryu, Y.S.2    Cho, H.M.3    Stubbs, N.4
  • 12
    • 1542348919 scopus 로고    scopus 로고
    • Identification of prestress-loss in PSC beams using modal information
    • Kim, J. T., Yun, C. B., Ryu, Y. S. and Cho, H. M. (2003b), "Identification of prestress-loss in PSC beams using modal information", Struct. Eng. Mech., 17(3-4), 467-482.
    • (2003) Struct. Eng. Mech , vol.17 , Issue.3-4 , pp. 467-482
    • Kim, J.T.1    Yun, C.B.2    Ryu, Y.S.3    Cho, H.M.4
  • 13
    • 33745967776 scopus 로고    scopus 로고
    • Hybrid health monitoring of structural joints using modal parameters and EMI signatures
    • Kim, J. T., Na, W. B., Park, J. H. and Hong, D. S. (2006), "Hybrid health monitoring of structural joints using modal parameters and EMI signatures", Proceedings of SPIE, 6174, 61742O.
    • (2006) Proceedings of SPIE , vol.6174
    • Kim, J.T.1    Na, W.B.2    Park, J.H.3    Hong, D.S.4
  • 14
    • 35649013150 scopus 로고    scopus 로고
    • Impedance-based structural health monitoring considering temperature effects
    • Koo, K. Y., Park, S., Lee, J. J., Yun, C. B. and Inman, D. J. (2007), "Impedance-based structural health monitoring considering temperature effects", Proceedings of SPIE, 6532, 65320C.
    • (2007) Proceedings of SPIE , vol.6532
    • Koo, K.Y.1    Park, S.2    Lee, J.J.3    Yun, C.B.4    Inman, D.J.5
  • 15
    • 26444532832 scopus 로고    scopus 로고
    • Time domain responses of a prestressed beam and prestress identification
    • Law, S. S. and Lu, J. R. (2005), "Time domain responses of a prestressed beam and prestress identification", J. Sound Vib., 288(4-5), 1011-1025.
    • (2005) J. Sound Vib , vol.288 , Issue.4-5 , pp. 1011-1025
    • Law, S.S.1    Lu, J.R.2
  • 16
    • 0028338103 scopus 로고
    • Coupled electromechanical analysis of adaptive material systems-determination of the actuator power consumption and system energy transfer
    • Liang, C., Sun, F. P. and Rogers, C. A. (1994), "Coupled electromechanical analysis of adaptive material systems-determination of the actuator power consumption and system energy transfer", J. Intell. Mater. Sys. Struct., 5(1), 12-20.
    • (1994) J. Intell. Mater. Sys. Struct , vol.5 , Issue.1 , pp. 12-20
    • Liang, C.1    Sun, F.P.2    Rogers, C.A.3
  • 17
    • 0030123294 scopus 로고    scopus 로고
    • Electro-mechanical impedance modeling of active material systems
    • Liang, C., Sun, F. P. and Rogers, C. A. (1996), "Electro-mechanical impedance modeling of active material systems", Smart Mater. Struct., 5(1), 171-186.
    • (1996) Smart Mater. Struct , vol.5 , Issue.1 , pp. 171-186
    • Liang, C.1    Sun, F.P.2    Rogers, C.A.3
  • 19
    • 0034276001 scopus 로고    scopus 로고
    • Behavior of prestressed beam strengthened with external tendons
    • Miyamoto, A., Tei, K., Nakamura, H. and Bull, J. W. (2000), "Behavior of prestressed beam strengthened with external tendons", J. Struct. Eng., 126, 1033-1044.
    • (2000) J. Struct. Eng , vol.126 , pp. 1033-1044
    • Miyamoto, A.1    Tei, K.2    Nakamura, H.3    Bull, J.W.4
  • 21
    • 0034529418 scopus 로고    scopus 로고
    • Impedance-based health monitoring of civil structural components
    • ASCE, 15.3-160
    • Park, G., Cudney, H. and Inman, D. J. (2000), "Impedance-based health monitoring of civil structural components", J. Infrastruct. Sys., ASCE, 6(4), 15.3-160.
    • (2000) J. Infrastruct. Sys , vol.6 , Issue.4
    • Park, G.1    Cudney, H.2    Inman, D.J.3
  • 22
    • 33846104944 scopus 로고    scopus 로고
    • Performance assessment and validation of piezoelectric activesensors in structural health monitoring
    • Park, G., Farrar, C. R. and Scalea, F. L. (2006a), "Performance assessment and validation of piezoelectric activesensors in structural health monitoring", Smart Mater. Struct., 15(6), 1673-1683.
    • (2006) Smart Mater. Struct , vol.15 , Issue.6 , pp. 1673-1683
    • Park, G.1    Farrar, C.R.2    Scalea, F.L.3
  • 23
    • 0032623597 scopus 로고    scopus 로고
    • Impedance-based structural health monitoring for temperature varying applications
    • Park, G., Kabeya, K., Cudney, H. H. and Inman, D. J. (1999), "Impedance-based structural health monitoring for temperature varying applications", JSME Int. J., 42, 249-258.
    • (1999) JSME Int. J , vol.42 , pp. 249-258
    • Park, G.1    Kabeya, K.2    Cudney, H.H.3    Inman, D.J.4
  • 24
    • 33748118459 scopus 로고    scopus 로고
    • Multiple crack detection of concrete structures using impedance-based structural health monitoring techniques
    • Park, S., Ahmad, S., Yun, C. B. and Roh, Y. (2006b), "Multiple crack detection of concrete structures using impedance-based structural health monitoring techniques", Experimental Mech., 46(5), 609-618.
    • (2006) Experimental Mech , vol.46 , Issue.5 , pp. 609-618
    • Park, S.1    Ahmad, S.2    Yun, C.B.3    Roh, Y.4
  • 25
    • 0028467061 scopus 로고
    • Prestress force effect on vibration frequency of concrete bridges
    • Saiidi, M., Douglas, B. and Feng, S. (1994), "Prestress force effect on vibration frequency of concrete bridges", J. Struct. Eng., 120, 2233-2241.
    • (1994) J. Struct. Eng , vol.120 , pp. 2233-2241
    • Saiidi, M.1    Douglas, B.2    Feng, S.3
  • 26
    • 0030230403 scopus 로고    scopus 로고
    • Variation of prestress force in a prestressed concrete bridge during the first 30 months
    • Saiidi, M., Shield, J., O'connor, D. and Jutchens, E. (1996), "Variation of prestress force in a prestressed concrete bridge during the first 30 months", PCI J., 41, 66-72.
    • (1996) PCI J , vol.41 , pp. 66-72
    • Saiidi, M.1    Shield, J.2    O'connor, D.3    Jutchens, E.4
  • 28
    • 16244368798 scopus 로고    scopus 로고
    • Generic impedance-based model for structure-piezoceramic interacting system
    • Yang, Y., Xu, J. and Soh, C. K. (2005), "Generic impedance-based model for structure-piezoceramic interacting system", J. Aerospace Eng., ASCE, 18(2), 93-101.
    • (2005) J. Aerospace Eng., ASCE , vol.18 , Issue.2 , pp. 93-101
    • Yang, Y.1    Xu, J.2    Soh, C.K.3
  • 29
    • 40849150875 scopus 로고    scopus 로고
    • Sensitivity of PZT impedance sensors for damage detection of concrete structures
    • Yang, Y. W., Hu, Y. H. and Lu, Y. (2008), "Sensitivity of PZT impedance sensors for damage detection of concrete structures", Sensors, 8(1), 327-346.
    • (2008) Sensors , vol.8 , Issue.1 , pp. 327-346
    • Yang, Y.W.1    Hu, Y.H.2    Lu, Y.3
  • 30
    • 1542274235 scopus 로고    scopus 로고
    • Comparative study on modal identification methods using output-only information
    • Yi, J. H. and Yun, C. B. (2004), "Comparative study on modal identification methods using output-only information", Struct. Eng. Mech., 17(3-4), 445-446.
    • (2004) Struct. Eng. Mech , vol.17 , Issue.3-4 , pp. 445-446
    • Yi, J.H.1    Yun, C.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.