-
1
-
-
33745221878
-
Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment
-
Schwarz M., Van der Geer J., Van Herk M., et al. Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment. Int J Radiat Oncol Biol Phys 65 (2006) 1260-1269
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.65
, pp. 1260-1269
-
-
Schwarz, M.1
Van der Geer, J.2
Van Herk, M.3
-
2
-
-
0034811943
-
Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients
-
Chen Q.S., Weinhous M.S., Deibel F.C., et al. Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients. Med Phys 28 (2001) 1850-1856
-
(2001)
Med Phys
, vol.28
, pp. 1850-1856
-
-
Chen, Q.S.1
Weinhous, M.S.2
Deibel, F.C.3
-
3
-
-
0037237809
-
Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning
-
Ford E.C., Mageras G.S., Yorke E., et al. Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys 30 (2003) 88-97
-
(2003)
Med Phys
, vol.30
, pp. 88-97
-
-
Ford, E.C.1
Mageras, G.S.2
Yorke, E.3
-
4
-
-
1242338927
-
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
-
Pan T., Lee T., Rietzel E., et al. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med Phys 31 (2004) 333-340
-
(2004)
Med Phys
, vol.31
, pp. 333-340
-
-
Pan, T.1
Lee, T.2
Rietzel, E.3
-
5
-
-
0037423954
-
Synchronized moving aperture radiation therapy (SMART): Average tumor trajectory for lung patients
-
Neicu T., Shirato H., Seppenwoolde Y., et al. Synchronized moving aperture radiation therapy (SMART): Average tumor trajectory for lung patients. Phys Med Biol 48 (2003) 587-598
-
(2003)
Phys Med Biol
, vol.48
, pp. 587-598
-
-
Neicu, T.1
Shirato, H.2
Seppenwoolde, Y.3
-
6
-
-
3042545916
-
Treatment plan optimization incorporating respiratory motion
-
Zhang T., Jeraj R., Keller H., et al. Treatment plan optimization incorporating respiratory motion. Med Phys 31 (2004) 1576-1586
-
(2004)
Med Phys
, vol.31
, pp. 1576-1586
-
-
Zhang, T.1
Jeraj, R.2
Keller, H.3
-
7
-
-
0842306300
-
4-Dimensional computed tomography imaging and treatment planning
-
Keall P. 4-Dimensional computed tomography imaging and treatment planning. Semin Radiat Oncol 14 (2004) 81-90
-
(2004)
Semin Radiat Oncol
, vol.14
, pp. 81-90
-
-
Keall, P.1
-
8
-
-
16344366951
-
4-Dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
-
Rietzel E., Chen G.T.Y., Choi N.C., et al. 4-Dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys 61 (2005) 1535-1550
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.61
, pp. 1535-1550
-
-
Rietzel, E.1
Chen, G.T.Y.2
Choi, N.C.3
-
9
-
-
33749422038
-
The management of respiratory motion in radiation oncology report of AAPM Task group 76
-
Keall P.J., Mageras G.S., Balter J.M., et al. The management of respiratory motion in radiation oncology report of AAPM Task group 76. Med Phys 33 (2006) 3874-3900
-
(2006)
Med Phys
, vol.33
, pp. 3874-3900
-
-
Keall, P.J.1
Mageras, G.S.2
Balter, J.M.3
-
10
-
-
33748576243
-
Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system
-
Keall P.J., Cattell H., Pokhrel D., et al. Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system. Int J Radiat Oncol Biol Phys 65 (2006) 1579-1584
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.65
, pp. 1579-1584
-
-
Keall, P.J.1
Cattell, H.2
Pokhrel, D.3
-
11
-
-
7244242296
-
DMLC leaf-pair optimal control of IMRT delivery for moving rigid target
-
Papiez L. DMLC leaf-pair optimal control of IMRT delivery for moving rigid target. Med Phys 31 (2004) 2742-2754
-
(2004)
Med Phys
, vol.31
, pp. 2742-2754
-
-
Papiez, L.1
-
12
-
-
20044385935
-
Temporo-spatial IMRT optimization: Concepts, implementation and initial results
-
Trofimov A., Rietzel E., Hsiao-Ming L., et al. Temporo-spatial IMRT optimization: Concepts, implementation and initial results. Phys Med Biol 50 (2005) 2779-2798
-
(2005)
Phys Med Biol
, vol.50
, pp. 2779-2798
-
-
Trofimov, A.1
Rietzel, E.2
Hsiao-Ming, L.3
-
13
-
-
34247869928
-
Automatic delineation of online head and neck CT images: Towards online adaptive radiotherapy
-
522-303
-
Zhang T., Chi Y., Meldolesi E., et al. Automatic delineation of online head and neck CT images: Towards online adaptive radiotherapy. Int J Radiat Oncol Biol Phys 68 (2007) 522-303
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.68
-
-
Zhang, T.1
Chi, Y.2
Meldolesi, E.3
-
14
-
-
0142057570
-
Adapting inverse planning to patient and organ geometrical variation: Algorithm and implementation
-
Birkner M., Yan D., Alber M., et al. Adapting inverse planning to patient and organ geometrical variation: Algorithm and implementation. Med Phys 30 (2003) 2822-2831
-
(2003)
Med Phys
, vol.30
, pp. 2822-2831
-
-
Birkner, M.1
Yan, D.2
Alber, M.3
-
15
-
-
0010990601
-
Dosimetric precision requirements in radiation therapy
-
Brahme A. Dosimetric precision requirements in radiation therapy. Acta Radiat Oncol 23 (1984) 379-391
-
(1984)
Acta Radiat Oncol
, vol.23
, pp. 379-391
-
-
Brahme, A.1
-
16
-
-
0033867216
-
Inverse planning incorporating organ motion
-
Li J., and Xing L. Inverse planning incorporating organ motion. Med Phys 27 (2000) 1573-1578
-
(2000)
Med Phys
, vol.27
, pp. 1573-1578
-
-
Li, J.1
Xing, L.2
-
17
-
-
4544356974
-
Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions
-
Unkelbach J., and Oelfke U. Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions. Phys Med Biol 49 (2004) 4005-4029
-
(2004)
Phys Med Biol
, vol.49
, pp. 4005-4029
-
-
Unkelbach, J.1
Oelfke, U.2
-
18
-
-
2642683174
-
An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient setup and internal organ motion
-
Lof J., Lind K., and Brahme A. An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient setup and internal organ motion. Phys Med Biol 43 (1998) 1605-1628
-
(1998)
Phys Med Biol
, vol.43
, pp. 1605-1628
-
-
Lof, J.1
Lind, K.2
Brahme, A.3
-
20
-
-
33645972885
-
Changes in the respiratory pattern during radiotherapy for cancer in the lung
-
Hugo G., Vargas C., Liang J., et al. Changes in the respiratory pattern during radiotherapy for cancer in the lung. Radiother Oncol 78 (2006) 326-331
-
(2006)
Radiother Oncol
, vol.78
, pp. 326-331
-
-
Hugo, G.1
Vargas, C.2
Liang, J.3
-
21
-
-
0035045155
-
Organ/patient geometric variation in external beam radiotherapy and its effect
-
Yan D., and Lockman D. Organ/patient geometric variation in external beam radiotherapy and its effect. Med Phys 28 (2001) 593-602
-
(2001)
Med Phys
, vol.28
, pp. 593-602
-
-
Yan, D.1
Lockman, D.2
-
22
-
-
36148932560
-
Online target position localization in the presence of respiration: A comparison of two methods
-
Hugo G., Liang J., Campbell J., et al. Online target position localization in the presence of respiration: A comparison of two methods. Int J Radiat Oncol Biol Phys 69 (2007) 1634-1641
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.69
, pp. 1634-1641
-
-
Hugo, G.1
Liang, J.2
Campbell, J.3
-
23
-
-
39749185557
-
Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy
-
Grill I.S., Hugo G., Kestin L., et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys 70 (2008) 1045-1056
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.70
, pp. 1045-1056
-
-
Grill, I.S.1
Hugo, G.2
Kestin, L.3
-
24
-
-
0038033835
-
The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator
-
Chui C.S., Yorke E., and Hong L. The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. Med Phys 30 (2003) 1736-1746
-
(2003)
Med Phys
, vol.30
, pp. 1736-1746
-
-
Chui, C.S.1
Yorke, E.2
Hong, L.3
-
25
-
-
0037036516
-
Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
-
Bortfeld T., Jokivarsi K., Goitein M., et al. Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation. Phys Med Biol 47 (2002) 2203-2220
-
(2002)
Phys Med Biol
, vol.47
, pp. 2203-2220
-
-
Bortfeld, T.1
Jokivarsi, K.2
Goitein, M.3
|