메뉴 건너뛰기




Volumn 266, Issue 21, 2008, Pages 4808-4815

Characterisation of a pre-cell hit detector to be used in single cell irradiation experiments at the Lund Nuclear Microprobe

Author keywords

E detector; Detector efficiency; Single ions; Thin silicon detector; Vacuum window

Indexed keywords

CELLS; CYTOLOGY; ELECTROLYSIS; ION BEAM LITHOGRAPHY; IONS; SEMICONDUCTING SILICON; SEMICONDUCTING SILICON COMPOUNDS; SILICON; SILICON WAFERS; VACUUM; VACUUM TECHNOLOGY; WINDOWS;

EID: 54049101943     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nimb.2008.07.011     Document Type: Article
Times cited : (6)

References (19)
  • 1
    • 0030862614 scopus 로고    scopus 로고
    • A charged-particle microbeam: I. Development of an experimental system for targeting cells individually with counted particles
    • Folkard M., Vojnovic B., Prise K.M., Bowey A.G., Locke R.J., Schettino G., and Michael B.D. A charged-particle microbeam: I. Development of an experimental system for targeting cells individually with counted particles. Int. J. Radiat. Biol. 72 (1997) 375
    • (1997) Int. J. Radiat. Biol. , vol.72 , pp. 375
    • Folkard, M.1    Vojnovic, B.2    Prise, K.M.3    Bowey, A.G.4    Locke, R.J.5    Schettino, G.6    Michael, B.D.7
  • 14
    • 20444468547 scopus 로고    scopus 로고
    • Fabrication and characterization of thin ΔE detectors for spectroscopic application
    • Thungström G., Westerberg L., Spohr R., and Petersson C.S. Fabrication and characterization of thin ΔE detectors for spectroscopic application. Nucl. Instr. and Meth. A 546 (2005) 312
    • (2005) Nucl. Instr. and Meth. A , vol.546 , pp. 312
    • Thungström, G.1    Westerberg, L.2    Spohr, R.3    Petersson, C.S.4
  • 15
    • 54049138544 scopus 로고    scopus 로고
    • J.F. Ziegler, SRIM 2006, Version SRIM-2006.01, .
    • J.F. Ziegler, SRIM 2006, Version SRIM-2006.01, .
  • 16
    • 33644503566 scopus 로고    scopus 로고
    • The Lund nuclear microprobe sub-micron set-up, part III: Sample stage, optical imaging and detector configuration in the experimental chamber
    • Elfman M., Pallon J., Auzelyte V., Kristiansson P., Malmqvist K., Nilsson C., Shariff A., and Wegdén M. The Lund nuclear microprobe sub-micron set-up, part III: Sample stage, optical imaging and detector configuration in the experimental chamber. Nucl. Instr. and Meth. B 231 (2005) 14
    • (2005) Nucl. Instr. and Meth. B , vol.231 , pp. 14
    • Elfman, M.1    Pallon, J.2    Auzelyte, V.3    Kristiansson, P.4    Malmqvist, K.5    Nilsson, C.6    Shariff, A.7    Wegdén, M.8
  • 19
    • 54049122346 scopus 로고    scopus 로고
    • GeoPIXE II, .
    • GeoPIXE II, .


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.