-
1
-
-
29244472857
-
Neuroscience nanotechnology: progress, opportunities and challenges
-
Silva G.A. Neuroscience nanotechnology: progress, opportunities and challenges. Nat Rev Neurosci 7 1 (2006) 65-74
-
(2006)
Nat Rev Neurosci
, vol.7
, Issue.1
, pp. 65-74
-
-
Silva, G.A.1
-
2
-
-
0026433724
-
Microfabrication techniques for integrated sensors and microsystems
-
Wise K.D., and Najafi K. Microfabrication techniques for integrated sensors and microsystems. Science 254 5036 (1991) 1335-1342
-
(1991)
Science
, vol.254
, Issue.5036
, pp. 1335-1342
-
-
Wise, K.D.1
Najafi, K.2
-
3
-
-
11144281250
-
Implantable neural probe systems for cortical neuroprostheses
-
Kipke D.R. Implantable neural probe systems for cortical neuroprostheses. Conf Proc IEEE Eng Med Biol Soc 7 (2004) 5344-5347
-
(2004)
Conf Proc IEEE Eng Med Biol Soc
, vol.7
, pp. 5344-5347
-
-
Kipke, D.R.1
-
4
-
-
0035095902
-
Flexible polyimide-based intracortical electrode arrays with bioactive capability
-
Rousche P.J., Pellinen D.S., Pivin Jr. D.P., Williams J.C., Vetter R.J., and Kipke D.R. Flexible polyimide-based intracortical electrode arrays with bioactive capability. IEEE Trans Biomed Eng 48 3 (2001) 361-371
-
(2001)
IEEE Trans Biomed Eng
, vol.48
, Issue.3
, pp. 361-371
-
-
Rousche, P.J.1
Pellinen, D.S.2
Pivin Jr., D.P.3
Williams, J.C.4
Vetter, R.J.5
Kipke, D.R.6
-
5
-
-
0031106324
-
The Utah intracortical electrode array: a recording structure for potential brain-computer interfaces
-
Maynard E.M., Nordhausen C.T., and Normann R.A. The Utah intracortical electrode array: a recording structure for potential brain-computer interfaces. Electroencephalogr Clin Neurophysiol 102 3 (1997) 228-239
-
(1997)
Electroencephalogr Clin Neurophysiol
, vol.102
, Issue.3
, pp. 228-239
-
-
Maynard, E.M.1
Nordhausen, C.T.2
Normann, R.A.3
-
6
-
-
57649166864
-
A brain implantable microsystem with hybrid RF/IR telemetry for advanced neuroengineering applications
-
Song Y.K., Patterson W.R., Bull C.W., Borton D.A., Li Y., Nurmikko A.V., et al. A brain implantable microsystem with hybrid RF/IR telemetry for advanced neuroengineering applications. Conf Proc IEEE Eng Med Biol Soc 1 (2007) 445-448
-
(2007)
Conf Proc IEEE Eng Med Biol Soc
, vol.1
, pp. 445-448
-
-
Song, Y.K.1
Patterson, W.R.2
Bull, C.W.3
Borton, D.A.4
Li, Y.5
Nurmikko, A.V.6
-
7
-
-
0032125652
-
Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex
-
Rousche P.J., and Normann R.A. Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex. J Neurosci Methods 82 1 (1998) 1-15
-
(1998)
J Neurosci Methods
, vol.82
, Issue.1
, pp. 1-15
-
-
Rousche, P.J.1
Normann, R.A.2
-
8
-
-
33746160271
-
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
-
Hochberg L.R., Serruya M.D., Friehs G.M., Mukand J.A., Saleh M., Caplan A.H., et al. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 442 7099 (2006) 164-171
-
(2006)
Nature
, vol.442
, Issue.7099
, pp. 164-171
-
-
Hochberg, L.R.1
Serruya, M.D.2
Friehs, G.M.3
Mukand, J.A.4
Saleh, M.5
Caplan, A.H.6
-
9
-
-
27744586837
-
Microstimulation in auditory cortex provides a substrate for detailed behaviors
-
Otto K.J., Rousche P.J., and Kipke D.R. Microstimulation in auditory cortex provides a substrate for detailed behaviors. Hear Res 210 1-2 (2005) 112-117
-
(2005)
Hear Res
, vol.210
, Issue.1-2
, pp. 112-117
-
-
Otto, K.J.1
Rousche, P.J.2
Kipke, D.R.3
-
10
-
-
20144368960
-
Cortical microstimulation in auditory cortex of rat elicits best-frequency dependent behaviors
-
Otto K.J., Rousche P.J., and Kipke D.R. Cortical microstimulation in auditory cortex of rat elicits best-frequency dependent behaviors. J Neural Eng 2 2 (2005) 42-51
-
(2005)
J Neural Eng
, vol.2
, Issue.2
, pp. 42-51
-
-
Otto, K.J.1
Rousche, P.J.2
Kipke, D.R.3
-
11
-
-
0141479956
-
Chronic, multisite, multielectrode recordings in macaque monkeys
-
Nicolelis M.A., Dimitrov D., Carmena J.M., Crist R., Lehew G., Kralik J.D., et al. Chronic, multisite, multielectrode recordings in macaque monkeys. Proc Natl Acad Sci U S A 100 19 (2003) 11041-11046
-
(2003)
Proc Natl Acad Sci U S A
, vol.100
, Issue.19
, pp. 11041-11046
-
-
Nicolelis, M.A.1
Dimitrov, D.2
Carmena, J.M.3
Crist, R.4
Lehew, G.5
Kralik, J.D.6
-
12
-
-
0030882195
-
A floating microwire technique for multichannel chronic neural recording and stimulation in the awake freely moving rat
-
Westby G.W., and Wang H. A floating microwire technique for multichannel chronic neural recording and stimulation in the awake freely moving rat. J Neurosci Methods 76 2 (1997) 123-133
-
(1997)
J Neurosci Methods
, vol.76
, Issue.2
, pp. 123-133
-
-
Westby, G.W.1
Wang, H.2
-
13
-
-
23644450358
-
Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
-
Biran R., Martin D.C., and Tresco P.A. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays. Exp Neurol 195 1 (2005) 115-126
-
(2005)
Exp Neurol
, vol.195
, Issue.1
, pp. 115-126
-
-
Biran, R.1
Martin, D.C.2
Tresco, P.A.3
-
14
-
-
34250177246
-
The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull
-
Biran R., Martin D.C., and Tresco P.A. The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. J Biomed Mater Res A 82 1 (2007) 169-178
-
(2007)
J Biomed Mater Res A
, vol.82
, Issue.1
, pp. 169-178
-
-
Biran, R.1
Martin, D.C.2
Tresco, P.A.3
-
15
-
-
26444445003
-
Response of brain tissue to chronically implanted neural electrodes
-
Polikov V.S., Tresco P.A., and Reichert W.M. Response of brain tissue to chronically implanted neural electrodes. J Neurosci Methods 148 1 (2005) 1-18
-
(2005)
J Neurosci Methods
, vol.148
, Issue.1
, pp. 1-18
-
-
Polikov, V.S.1
Tresco, P.A.2
Reichert, W.M.3
-
16
-
-
0036130785
-
Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium
-
Rosengren A., Wallman L., Danielsen N., Laurell T., and Bjursten L.M. Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium. IEEE Trans Biomed Eng 49 4 (2002) 392-399
-
(2002)
IEEE Trans Biomed Eng
, vol.49
, Issue.4
, pp. 392-399
-
-
Rosengren, A.1
Wallman, L.2
Danielsen, N.3
Laurell, T.4
Bjursten, L.M.5
-
17
-
-
36248954063
-
Gallium phosphide nanowires as a substrate for cultured neurons
-
Hallstrom W., Martensson T., Prinz C., Gustavsson P., Montelius L., Samuelson L., et al. Gallium phosphide nanowires as a substrate for cultured neurons. Nano Lett 7 10 (2007) 2960-2965
-
(2007)
Nano Lett
, vol.7
, Issue.10
, pp. 2960-2965
-
-
Hallstrom, W.1
Martensson, T.2
Prinz, C.3
Gustavsson, P.4
Montelius, L.5
Samuelson, L.6
-
18
-
-
9744265721
-
Electrical properties of individual single-crystalline gallium phosphide nanowires with an outer oxide shell
-
Kim J.R., Kim B.K., Lee J.O., Kim J., Seo H.J., Lee C.J., et al. Electrical properties of individual single-crystalline gallium phosphide nanowires with an outer oxide shell. Nanotechnology 15 11 (2004) 1397-1400
-
(2004)
Nanotechnology
, vol.15
, Issue.11
, pp. 1397-1400
-
-
Kim, J.R.1
Kim, B.K.2
Lee, J.O.3
Kim, J.4
Seo, H.J.5
Lee, C.J.6
-
19
-
-
33645012936
-
Assessment of GaN chips for culturing cerebellar granule neurons
-
Young T.H., and Chen C.R. Assessment of GaN chips for culturing cerebellar granule neurons. Biomaterials 27 18 (2006) 3361-3367
-
(2006)
Biomaterials
, vol.27
, Issue.18
, pp. 3361-3367
-
-
Young, T.H.1
Chen, C.R.2
-
21
-
-
0028876630
-
Electron microscopic observations on the soft tissue around clinical long-term percutaneous titanium implants
-
Holgers K.M., Thomsen P., Tjellstrom A., and Ericson L.E. Electron microscopic observations on the soft tissue around clinical long-term percutaneous titanium implants. Biomaterials 16 2 (1995) 83-90
-
(1995)
Biomaterials
, vol.16
, Issue.2
, pp. 83-90
-
-
Holgers, K.M.1
Thomsen, P.2
Tjellstrom, A.3
Ericson, L.E.4
-
22
-
-
0032128109
-
Analysis of the inflammatory response to titanium and PTFE implants in soft tissue by macrophage phenotype quantification
-
Rosengren A., Bjursten L.M., and Danielsen N. Analysis of the inflammatory response to titanium and PTFE implants in soft tissue by macrophage phenotype quantification. J Mater Sci Mater Med 9 7 (1998) 415-420
-
(1998)
J Mater Sci Mater Med
, vol.9
, Issue.7
, pp. 415-420
-
-
Rosengren, A.1
Bjursten, L.M.2
Danielsen, N.3
-
23
-
-
0031193361
-
Inflammatory reaction dependence on implant localization in rat soft tissue models
-
Rosengren A., Danielsen N., and Bjursten L.M. Inflammatory reaction dependence on implant localization in rat soft tissue models. Biomaterials 18 14 (1997) 979-987
-
(1997)
Biomaterials
, vol.18
, Issue.14
, pp. 979-987
-
-
Rosengren, A.1
Danielsen, N.2
Bjursten, L.M.3
-
25
-
-
0026657012
-
Immune-response in biocompatibility
-
Remes A., and Williams D.F. Immune-response in biocompatibility. Biomaterials 13 11 (1992) 731-743
-
(1992)
Biomaterials
, vol.13
, Issue.11
, pp. 731-743
-
-
Remes, A.1
Williams, D.F.2
-
26
-
-
0030250736
-
Immunohistochemical studies on the distribution of albumin, fibrinogen, fibronectin, IgG and collagen around PTFE and titanium implants
-
Rosengren A., Johansson B.R., Danielsen N., Thomsen P., and Ericson L.E. Immunohistochemical studies on the distribution of albumin, fibrinogen, fibronectin, IgG and collagen around PTFE and titanium implants. Biomaterials 17 18 (1996) 1779-1786
-
(1996)
Biomaterials
, vol.17
, Issue.18
, pp. 1779-1786
-
-
Rosengren, A.1
Johansson, B.R.2
Danielsen, N.3
Thomsen, P.4
Ericson, L.E.5
-
27
-
-
0026556487
-
Dissimilar aluminum and gallium permeation of the blood-brain barrier demonstrated by in vivo microdialysis
-
Allen D.D., and Yokel R.A. Dissimilar aluminum and gallium permeation of the blood-brain barrier demonstrated by in vivo microdialysis. J Neurochem 58 3 (1992) 903-908
-
(1992)
J Neurochem
, vol.58
, Issue.3
, pp. 903-908
-
-
Allen, D.D.1
Yokel, R.A.2
-
28
-
-
3242791017
-
Toxicity of indium arsenide, gallium arsenide, and aluminium gallium arsenide
-
Tanaka A. Toxicity of indium arsenide, gallium arsenide, and aluminium gallium arsenide. Toxicol Appl Pharmacol 198 (2004) 405-411
-
(2004)
Toxicol Appl Pharmacol
, vol.198
, pp. 405-411
-
-
Tanaka, A.1
|