Methods of measuring intraocular pressure independently of central corneal thickness;Hornhautdickenunabhängige Methoden der Messung des Augeninnendrucks

Author keywords

Corneal hysteresis; Dynamic contour tonometry; Glaucoma; Goldmann applanation tonometry; Intraocular pressure

Indexed keywords

ARTICLE; COMPARATIVE STUDY; CORNEA; DIFFERENTIAL DIAGNOSIS; GLAUCOMA; HISTOLOGY; HUMAN; INTRAOCULAR PRESSURE; METHODOLOGY; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY; STATISTICAL ANALYSIS;

EID: 52949108464     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-008-1729-8     Document Type: Article
Times cited : (14)

References (16)
  • 1
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135-160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 33745698126 scopus 로고    scopus 로고
    • Augeninnendruck und Hornhautdicke. Ein Vergleich zwischen Non-Contact-Tonometrie und Applanations-tonometrie.
    • Domke N, Hager A, Wiegand W (2006) Augeninnendruck und Hornhautdicke. Ein Vergleich zwischen Non-Contact-Tonometrie und Applanations-tonometrie. Ophthalmologe 103:583-587
    • (2006) Ophthalmologe , vol.103 , pp. 583-587
    • Domke, N.1    Hager, A.2    Wiegand, W.3
  • 3
    • 0016766726 scopus 로고
    • Klinische und experimentelle Untersuchungen mit dem Non-contact-Tonometer.
    • Draeger J, Jessen K, Haselmann G (1975) Klinische und experimentelle Untersuchungen mit dem Non-contact-Tonometer. Klin Monatsbl Augenheilkd 167:27-34
    • (1975) Klin Monatsbl Augenheilkd , vol.167 , pp. 27-34
    • Draeger, J.1    Jessen, K.2    Haselmann, G.3
  • 4
    • 70449195078 scopus 로고
    • Über Applanations-tonometrie.
    • Goldmann H, Schmidt T (1957) Über Applanations-tonometrie. Ophthalmologica 134:221-241
    • (1957) Ophthalmologica , vol.134 , pp. 221-241
    • Goldmann, H.1    Schmidt, T.2
  • 5
    • 25644446762 scopus 로고    scopus 로고
    • Evaluation of tonometric correction factors
    • Gunvant R O'Leary DJ, Baskaran M et al. (2005) Evaluation of tonometric correction factors. J Glaucoma 14:337-343
    • (2005) J Glaucoma , vol.14 , pp. 337-343
    • Gunvant, R.1    O'Leary, D.J.2    Baskaran, M.3
  • 7
    • 34548203771 scopus 로고    scopus 로고
    • Changes of corneal hysteresis following clear corneal cataract surgery
    • Hager A, Loge K, Schroeder B et al. (2007) Changes of corneal hysteresis following clear corneal cataract surgery. Am J Ophthalmol 144:341-346
    • (2007) Am J Ophthalmol , vol.144 , pp. 341-346
    • Hager, A.1    Loge, K.2    Schroeder, B.3
  • 8
    • 34547349120 scopus 로고    scopus 로고
    • Einfluss von Cornealer Hysterese und Cornealem Resistenzfaktor auf die Messung des intraokularen Druckes.
    • Hager A, Schroeder B, Sadeghi M et al. (2007) Einfluss von Cornealer Hysterese und Cornealem Resistenzfaktor auf die Messung des intraokularen Druckes. Ophthalmologe 104:484-489
    • (2007) Ophthalmologe , vol.104 , pp. 484-489
    • Hager, A.1    Schroeder, B.2    Sadeghi, M.3
  • 9
    • 33646901276 scopus 로고    scopus 로고
    • Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    • Herndon LW (2006) Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol 17:115-119
    • (2006) Curr Opin Ophthalmol , vol.17 , pp. 115-119
    • Herndon, L.W.1
  • 10
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with goldmann applanation tonometry
    • Kaufmann C, Bachmann LM, Thiel MA (2004) Comparison of dynamic contour tonometry with goldmann applanation tonometry. Invest Ophthalmol Vis Sci 45:3118-3121
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 11
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • Kaufmann C, Bachmann LM, Thiel MA (2003) Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci 44:3790-3794
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3790-3794
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 13
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31:156-162
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 14
    • 33748924156 scopus 로고    scopus 로고
    • Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the Ocular Response Analyzer
    • Medeiros FA, Weinreb RN (2006) Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the Ocular Response Analyzer. J Glaucoma 15:364-370
    • (2006) J Glaucoma , vol.15 , pp. 364-370
    • Medeiros, F.A.1    Weinreb, R.N.2
  • 15
    • 0035164733 scopus 로고    scopus 로고
    • Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry
    • Recep OF, Hasiripi H, Cagil N, Sarikatipoglu H (2001 ) Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry. J Cataract Refract Surg 27:1787-1791
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1787-1791
    • Recep, O.F.1    Hasiripi, H.2    Cagil, N.3    Sarikatipoglu, H.4
  • 16
    • 21344460937 scopus 로고    scopus 로고
    • The influence of central corneal thickness and age in intraocular pressure measured by pneumotonometry, non-contact-tonometry, theTono-Pen XL, and Goldmann applanation tonometry
    • Tonnu PA, HoT, Newson T et al. (2005)The influence of central corneal thickness and age in intraocular pressure measured by pneumotonometry, non-contact-tonometry, theTono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 89:851-854
    • (2005) Br J Ophthalmol , vol.89 , pp. 851-854
    • Tonnu, P.A.1    Ho, T.2    Newson, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.