메뉴 건너뛰기




Volumn , Issue , 2008, Pages

Two-end unsynchronized fault location algorithm for double-circuit series compensated lines

Author keywords

ATP EMTP; Double circuit line; Fault location; Series compensation; Simulation; Two end unsynchronized measurement

Indexed keywords

ALGORITHMS; ELECTRIC SURGES; ENERGY CONVERSION; LOCATION; POTENTIAL ENERGY; POTENTIAL ENERGY SURFACES; SUBROUTINES;

EID: 52349087644     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2008.4596638     Document Type: Conference Paper
Times cited : (19)

References (16)
  • 1
    • 52349097288 scopus 로고    scopus 로고
    • M. S. Sachdev (coordinator), Advancements in microprocessor based protection and communication, IEEE Tutorial, Publ. No. 97TP120-0, 1997.
    • M. S. Sachdev (coordinator), "Advancements in microprocessor based protection and communication", IEEE Tutorial, Publ. No. 97TP120-0, 1997.
  • 2
    • 52349104909 scopus 로고    scopus 로고
    • IEEE Std C37.114: IEEE Guide for Determining Fault Location on AC Transmission and Distribution lines, IEEE Power Engineering Society Publ., pp. 1-42, 8 June 2005.
    • IEEE Std C37.114: "IEEE Guide for Determining Fault Location on AC Transmission and Distribution lines", IEEE Power Engineering Society Publ., pp. 1-42, 8 June 2005.
  • 3
    • 0032682435 scopus 로고    scopus 로고
    • A new accurate fault locating algorithm for series compensated lines
    • M. M. Saha, J. Izykowski, E. Rosolowski, B. Kasztenny, "A new accurate fault locating algorithm for series compensated lines", IEEE Trans. Power Del., Vol. 14, No. 3, pp. 789-797, 1999.
    • (1999) IEEE Trans. Power Del , vol.14 , Issue.3 , pp. 789-797
    • Saha, M.M.1    Izykowski, J.2    Rosolowski, E.3    Kasztenny, B.4
  • 4
    • 0034223817 scopus 로고    scopus 로고
    • Accurate fault location algorithm for series compensated transmission lines
    • Sadeh, N. Hadjsaid, A. M. Ranjbar, R. Feuillet, "Accurate fault location algorithm for series compensated transmission lines", IEEE Trans. Power Del., Vol. 15, No. 3, pp. 1027-1033, 2000.
    • (2000) IEEE Trans. Power Del , vol.15 , Issue.3 , pp. 1027-1033
    • Sadeh, N.1    Hadjsaid, A.M.2    Ranjbar, R.F.3
  • 6
    • 0030260934 scopus 로고    scopus 로고
    • Algorithms for locating faults on series compensated lines using neural network and deterministic methods
    • D. Novosel, B. Bachmann, D. Hart, Y. Hu, M. M. Saha, "Algorithms for locating faults on series compensated lines using neural network and deterministic methods", IEEE Trans. Power Del., Vol. 11, No. 4, pp. 1728-1736, 1996.
    • (1996) IEEE Trans. Power Del , vol.11 , Issue.4 , pp. 1728-1736
    • Novosel, D.1    Bachmann, B.2    Hart, D.3    Hu, Y.4    Saha, M.M.5
  • 7
    • 11244289074 scopus 로고    scopus 로고
    • A novel fault location technique based on current signals only for thyristor controlled series compensated transmission lines using wavelet analysis and self organising map neural networks
    • W. J. Cheong, R. K. Aggarwal, "A novel fault location technique based on current signals only for thyristor controlled series compensated transmission lines using wavelet analysis and self organising map neural networks", Proceedings of 8-th IEE International Conference on Developments in Power System Protection, Vol. 1, pp. 224-227, 2004.
    • (2004) Proceedings of 8-th IEE International Conference on Developments in Power System Protection , vol.1 , pp. 224-227
    • Cheong, W.J.1    Aggarwal, R.K.2
  • 9
    • 52349113705 scopus 로고    scopus 로고
    • Accurate fault location algorithm for series compensated lines using two-terminal unsynchronised measurements and Hydro-Quebec's field experience
    • Spokane, Washington, pp
    • C. Fecteau, "Accurate fault location algorithm for series compensated lines using two-terminal unsynchronised measurements and Hydro-Quebec's field experience", Proceedings of 33rd Annual Western Protective Relay Conference, Spokane, Washington, pp. 1-16, 2006.
    • (2006) Proceedings of 33rd Annual Western Protective Relay Conference , pp. 1-16
    • Fecteau, C.1
  • 10
    • 0036118598 scopus 로고    scopus 로고
    • A new PMU-based fault location algorithm for series compensated lines
    • C.-S. Yu, C.-W. Liu, S.-L. Yu, J.-A. Jiang, "A new PMU-based fault location algorithm for series compensated lines", IEEE Trans. Power Del, Vol. 17, No. 1, pp. 33-46, 2002.
    • (2002) IEEE Trans. Power Del , vol.17 , Issue.1 , pp. 33-46
    • Yu, C.-S.1    Liu, C.-W.2    Yu, S.-L.3    Jiang, J.-A.4
  • 11
    • 84861492284 scopus 로고    scopus 로고
    • Fault location for teed circuits with mutually coupled lines and series capacitors
    • IEEE Catalog Number 03EX7I9C
    • C. Y. Evrenosoglu, A. Abur, "Fault location for teed circuits with mutually coupled lines and series capacitors", Proceedings of IEEE Bologna Power Tech Conference, IEEE Catalog Number 03EX7I9C, 2003.
    • (2003) Proceedings of IEEE Bologna Power Tech Conference
    • Evrenosoglu, C.Y.1    Abur, A.2
  • 12
    • 42549141483 scopus 로고    scopus 로고
    • C37.118: "IEEE Standard for Synchrophasors for Power Systems
    • IEEE Std, 22 March
    • IEEE Std. C37.118: "IEEE Standard for Synchrophasors for Power Systems", IEEE Power Engineering Society Publ., pp. 1-65, 22 March 2006.
    • (2006) IEEE Power Engineering Society Publ , pp. 1-65
  • 13
    • 50249171236 scopus 로고    scopus 로고
    • Optimal estimate of transmission line fault location considering measurement errors
    • Y. Liao, M. Kezunovic, "Optimal estimate of transmission line fault location considering measurement errors", IEEE Trans. Power Del., Vol. 22, No. 3, pp. 1335-1341, 2007.
    • (2007) IEEE Trans. Power Del , vol.22 , Issue.3 , pp. 1335-1341
    • Liao, Y.1    Kezunovic, M.2
  • 14
    • 33750156781 scopus 로고    scopus 로고
    • Unsynchronised two-terminal transmission-line fault-location without using line parameters
    • Y. Liao, S. Elangovan, "Unsynchronised two-terminal transmission-line fault-location without using line parameters", IEE Proc.-Gener. Transm. Distrib., Vol. 153, No. 6, pp. 639-643, 2006.
    • (2006) IEE Proc.-Gener. Transm. Distrib , vol.153 , Issue.6 , pp. 639-643
    • Liao, Y.1    Elangovan, S.2
  • 15
    • 1942503937 scopus 로고    scopus 로고
    • Locating faults in parallel transmission lines under availability of complete measurements at one end
    • J. IzykowsM, E. Rosolowski, M. M. Saha, "Locating faults in parallel transmission lines under availability of complete measurements at one end", IEE Proc.-Gener. Transm. Distrib., Vol. 151, No. 2, pp. 268-273, 2004.
    • (2004) IEE Proc.-Gener. Transm. Distrib , vol.151 , Issue.2 , pp. 268-273
    • IzykowsM, J.1    Rosolowski, E.2    Saha, M.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.