Volumn 22, Issue 3, 2007, Pages 1335-1341

Optimal estimate of transmission line fault location considering measurement errors

Author keywords

Bad measurement detection and identification; Distributed parameter line model; Fault location; Nonlinear estimation theory; Optimal estimator

Indexed keywords

ELECTRIC FAULT LOCATION; ELECTRIC LINES; ERRORS; FAULT DETECTION; FORECASTING; MEASUREMENTS; MOBILE TELECOMMUNICATION SYSTEMS; POWER TRANSMISSION; TRANSMISSION LINE THEORY;

EID: 50249171236     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2007.899554     Document Type: Article
Times cited : (105)

References (24)
  • 2
    • 0020166862 scopus 로고
    • Development of a new type fault locator using the one-terminal voltage and current data
    • Aug
    • K. Takagi, Y. Yomakoshi, M. Yamaura, R. Kondow, and T. Matsushima, "Development of a new type fault locator using the one-terminal voltage and current data," IEEE Trans. Power App. Syst., vol. PAS-101, no. 8, pp. 2892-2898, Aug. 1982.
    • (1982) IEEE Trans. Power App. Syst , vol.PAS-101 , Issue.8 , pp. 2892-2898
    • Takagi, K.1    Yomakoshi, Y.2    Yamaura, M.3    Kondow, R.4    Matsushima, T.5
  • 3
    • 0022010176 scopus 로고
    • An accurate fault locator with compensation for apparent reactance in the fault resistance resulting from remote-end infeed
    • Feb
    • L. Eriksson, M. M. Saha, and G. D. Rockefeller, "An accurate fault locator with compensation for apparent reactance in the fault resistance resulting from remote-end infeed," IEEE Trans. Power App. Syst., vol. PAS-104, no. 2, pp. 424-436, Feb. 1985.
    • (1985) IEEE Trans. Power App. Syst , vol.PAS-104 , Issue.2 , pp. 424-436
    • Eriksson, L.1    Saha, M.M.2    Rockefeller, G.D.3
  • 4
    • 0032188351 scopus 로고    scopus 로고
    • Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral system
    • Oct
    • Q. Zhang, Y. Zhang, W. Song, and D. Fang, "Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral system," IEEE Trans. Power Del., vol. 13, no. 4, pp. 1086-1092, Oct. 1998.
    • (1998) IEEE Trans. Power Del , vol.13 , Issue.4 , pp. 1086-1092
    • Zhang, Q.1    Zhang, Y.2    Song, W.3    Fang, D.4
  • 5
    • 0032155849 scopus 로고    scopus 로고
    • Digital distance relaying algorithm for first-zone protection for parallel transmission lines
    • Sep
    • Y. Liao and S. Elangovan, "Digital distance relaying algorithm for first-zone protection for parallel transmission lines," Proc. Inst. Elect. Eng. C, Gen., Transm. Distrib., vol. 145, no. 5, pp. 531-536, Sep. 1998.
    • (1998) Proc. Inst. Elect. Eng. C, Gen., Transm. Distrib , vol.145 , Issue.5 , pp. 531-536
    • Liao, Y.1    Elangovan, S.2
  • 6
    • 1942503937 scopus 로고    scopus 로고
    • Locating faults in parallel transmission lines under availability of complete measurements at one end
    • Mar. 2
    • J. Izykowski, E. Rosolowski, and M. M. Saha, "Locating faults in parallel transmission lines under availability of complete measurements at one end," Proc. Inst. Elect. Eng. C, Gen., Transm. Distrib., vol. 151, no. 2, pp. 268-273, Mar. 2, 2004.
    • (2004) Proc. Inst. Elect. Eng. C, Gen., Transm. Distrib , vol.151 , Issue.2 , pp. 268-273
    • Izykowski, J.1    Rosolowski, E.2    Saha, M.M.3
  • 7
    • 0032187490 scopus 로고    scopus 로고
    • Distance protection and fault location utilizing only phase current phasors
    • Oct
    • M. Djuric, Z. Radojevic, and V. Terzija, "Distance protection and fault location utilizing only phase current phasors," IEEE Trans. Power Del., vol. 13, no. 4, pp. 1020-1026, Oct. 1998.
    • (1998) IEEE Trans. Power Del , vol.13 , Issue.4 , pp. 1020-1026
    • Djuric, M.1    Radojevic, Z.2    Terzija, V.3
  • 8
    • 0029736561 scopus 로고    scopus 로고
    • Unsynchronized two-terminal fault location estimation
    • Jan
    • Novosel, D. G. Hart, E. Udren, and J. Garitty, "Unsynchronized two-terminal fault location estimation," IEEE Trans. Power Del., vol. 11, no. 1, pp. 130-138, Jan. 1996.
    • (1996) IEEE Trans. Power Del , vol.11 , Issue.1 , pp. 130-138
    • Novosel, D.1    Hart, G.2    Udren, E.3    Garitty, J.4
  • 9
    • 0026623757 scopus 로고
    • A new fault location technique for two-and three-terminal lines
    • Jan
    • A. A. Girgis, D. G. Hart, and W. L. Peterson, "A new fault location technique for two-and three-terminal lines," IEEE Trans. Power Del. vol. 7, no. 1, pp. 98-107, Jan. 1992.
    • (1992) IEEE Trans. Power Del , vol.7 , Issue.1 , pp. 98-107
    • Girgis, A.A.1    Hart, D.G.2    Peterson, W.L.3
  • 10
    • 0023844294 scopus 로고    scopus 로고
    • A technique for estimating transmission line fault locations from digital impedance relay measurements
    • Jan
    • M. Sachdev and R. Agarwal, "A technique for estimating transmission line fault locations from digital impedance relay measurements," IEEE Trans. Power Del., vol. 13, no. 1, pp. 121-129, Jan. 1998.
    • (1998) IEEE Trans. Power Del , vol.13 , Issue.1 , pp. 121-129
    • Sachdev, M.1    Agarwal, R.2
  • 11
    • 0034290066 scopus 로고    scopus 로고
    • Fault location using distributed parameter transmission line model
    • Oct
    • A. Gopalakrishnan, M. Kezunovic, S. M. McKenna, and D. M. Hamai, "Fault location using distributed parameter transmission line model," IEEE Trans. Power Del., vol. 15, no. 4, pp. 1169-1174, Oct. 2000.
    • (2000) IEEE Trans. Power Del , vol.15 , Issue.4 , pp. 1169-1174
    • Gopalakrishnan, A.1    Kezunovic, M.2    McKenna, S.M.3    Hamai, D.M.4
  • 12
    • 7244254322 scopus 로고    scopus 로고
    • A new PMU-based fault detection/location technique for transmission lines with consideration of arcing fault discrimination - Part 1: Theory and algorithms
    • Oct
    • Y. H. Lin, C. W. Liu, and C. S. Chen, "A new PMU-based fault detection/location technique for transmission lines with consideration of arcing fault discrimination - Part 1: Theory and algorithms," IEEE Trans. Power Del., vol. 19, no. 4, pp. 1587-1593, Oct. 2004.
    • (2004) IEEE Trans. Power Del , vol.19 , Issue.4 , pp. 1587-1593
    • Lin, Y.H.1    Liu, C.W.2    Chen, C.S.3
  • 13
    • 0026939751 scopus 로고
    • Development of an advanced transmission line fault location system, Part II-Algorithm development and simulation
    • Oct
    • D. J. Lawrence, L. Cabeza, and L. Hochberg, "Development of an advanced transmission line fault location system, Part II-Algorithm development and simulation," IEEE Trans. Power Del., vol. 7, no. 4, pp. 1972-1983, Oct. 1992.
    • (1992) IEEE Trans. Power Del , vol.7 , Issue.4 , pp. 1972-1983
    • Lawrence, D.J.1    Cabeza, L.2    Hochberg, L.3
  • 14
    • 0026938291 scopus 로고
    • Development of an advanced transmission line fault location system, Part I-Input transducer analysis and requirements
    • Oct
    • D. J. Lawrence, L. Cabeza, and L. Hochberg, "Development of an advanced transmission line fault location system, Part I-Input transducer analysis and requirements," IEEE Trans. Power Del., vol. 7, no. 4, pp. 1963-1971, Oct. 1992.
    • (1992) IEEE Trans. Power Del , vol.7 , Issue.4 , pp. 1963-1971
    • Lawrence, D.J.1    Cabeza, L.2    Hochberg, L.3
  • 15
    • 7244231172 scopus 로고    scopus 로고
    • Fault location on a transmission line using synchronized voltage measurements
    • Oct
    • S. M. Brahma, "Fault location on a transmission line using synchronized voltage measurements," IEEE Trans. Power Del., vol. 19, no. 4, pp. 1619-1622, Oct. 2004.
    • (2004) IEEE Trans. Power Del , vol.19 , Issue.4 , pp. 1619-1622
    • Brahma, S.M.1
  • 16
    • 0032187785 scopus 로고    scopus 로고
    • Accurate fault location using wavelets
    • Dec
    • F. H. Magnago and A. Abut, "Accurate fault location using wavelets," IEEE Trans. Power Del., vol. 13, no. 4, pp. 1475-1480, Dec. 1998.
    • (1998) IEEE Trans. Power Del , vol.13 , Issue.4 , pp. 1475-1480
    • Magnago, F.H.1    Abut, A.2
  • 17
    • 2542469139 scopus 로고    scopus 로고
    • Locating faults in the transmission network using sparse field measurements, simulation data and genetic algorithms
    • Oct
    • S. Luo, M. Kezunovic, and D. R. Sevcik, "Locating faults in the transmission network using sparse field measurements, simulation data and genetic algorithms," Elect. Power Syst. Res., vol. 71, no. 2, pp. 169-177, Oct. 2004.
    • (2004) Elect. Power Syst. Res , vol.71 , Issue.2 , pp. 169-177
    • Luo, S.1    Kezunovic, M.2    Sevcik, D.R.3
  • 18
    • 27844461149 scopus 로고    scopus 로고
    • Best ANN structures for fault location in single-and double-circuit transmission lines
    • Oct
    • J. Gracia, A. J. Mazon, and I. Zamora, "Best ANN structures for fault location in single-and double-circuit transmission lines," IEEE Trans. Power Del., vol. 20, no. 4, pp. 2389-2395, Oct. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.4 , pp. 2389-2395
    • Gracia, J.1    Mazon, A.J.2    Zamora, I.3
  • 19
    • 1942503972 scopus 로고    scopus 로고
    • Application of RBF neural network to fault classification and location in transmission lines
    • Mar
    • R. N. Mahanty and P. B. D. Gupta, "Application of RBF neural network to fault classification and location in transmission lines," Proc. Inst. Elect. Eng., Gen., Transm. Distrib., vol. 151, no. 2, pp. 201-212, Mar. 2004.
    • (2004) Proc. Inst. Elect. Eng., Gen., Transm. Distrib , vol.151 , Issue.2 , pp. 201-212
    • Mahanty, R.N.1    Gupta, P.B.D.2
  • 21
    • 0029270856 scopus 로고
    • Relay performance considerations with low-ratio CTs and high-fault currents
    • Mar./Apr
    • J. R. Linders, C. W. Barnett, and J. W. Chadwick et al., "Relay performance considerations with low-ratio CTs and high-fault currents," IEEE Trans. Ind. Appl., vol. 31, no. 2, pp. 392-404, Mar./Apr. 1995.
    • (1995) IEEE Trans. Ind. Appl , vol.31 , Issue.2 , pp. 392-404
    • Linders, J.R.1    Barnett, C.W.2    Chadwick, J.W.3