메뉴 건너뛰기




Volumn 37, Issue 8, 2008, Pages 1335-1349

Optimising the precision for localising fluorescent proteins in living cells by 2D Gaussian fitting of digital images: Application to COPII-coated endoplasmic reticulum exit sites

Author keywords

Electron multiplied charge coupled devices; Fluorescence spectroscopy; Live cell microscopy; Molecular motors; Particle tracking; Theoretical models

Indexed keywords

COAT PROTEIN COMPLEX II; KINESIN; MOLECULAR MOTOR; YELLOW FLUORESCENT PROTEIN;

EID: 51849167647     PISSN: 01757571     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00249-008-0343-7     Document Type: Article
Times cited : (6)

References (21)
  • 1
    • 0026528045 scopus 로고
    • Tracking of cell surface receptors by fluorescence digital imaging microscopy using a charge-coupled device camera
    • CM Anderson GN Gerogiou IEG Morrison GVW Stevenson RJ Cherry 1992 Tracking of cell surface receptors by fluorescence digital imaging microscopy using a charge-coupled device camera J Cell Sci 101 415
    • (1992) J Cell Sci , vol.101 , pp. 415
    • Anderson, C.M.1    Gerogiou, G.N.2    Morrison, I.E.G.3    Stevenson, G.V.W.4    Cherry, R.J.5
  • 3
    • 24144437239 scopus 로고    scopus 로고
    • Tracking single particles: A user-friendly quantitative evaluation
    • BC Carter GT Shubeita SP Gross 2005 Tracking single particles: a user-friendly quantitative evaluation Phys Biol 2 60
    • (2005) Phys Biol , vol.2 , pp. 60
    • Carter, B.C.1    Shubeita, G.T.2    Gross, S.P.3
  • 4
    • 0034817343 scopus 로고    scopus 로고
    • Quantitative comparison of algorithms for tracking single fluorescent particles
    • MK Cheezum WF Walker WH Guilford 2001 Quantitative comparison of algorithms for tracking single fluorescent particles Biophys J 81 2378
    • (2001) Biophys J , vol.81 , pp. 2378
    • Cheezum, M.K.1    Walker, W.F.2    Guilford, W.H.3
  • 5
    • 33645520476 scopus 로고    scopus 로고
    • A non-Gaussian distribution quantifies distances measured with fluorescence localization techniques
    • LS Churchman H Flyvbjerg JA Spudich 2006 A non-Gaussian distribution quantifies distances measured with fluorescence localization techniques Biophys J 90 668
    • (2006) Biophys J , vol.90 , pp. 668
    • Churchman, L.S.1    Flyvbjerg, H.2    Spudich, J.A.3
  • 6
    • 0029977418 scopus 로고    scopus 로고
    • Methods of digital video microscopy for colloidal studies
    • JC Crocker DG Grier 1996 Methods of digital video microscopy for colloidal studies J Colloid Interface Sci 179 298
    • (1996) J Colloid Interface Sci , vol.179 , pp. 298
    • Crocker, J.C.1    Grier, D.G.2
  • 7
    • 39449123938 scopus 로고    scopus 로고
    • A model for the self-organization of exit sites in the endoplasmic reticulum
    • S Heinzer S Wörz C Kalla K Rohr M Weiss 2007 A model for the self-organization of exit sites in the endoplasmic reticulum J Cell Sci 121 55
    • (2007) J Cell Sci , vol.121 , pp. 55
    • Heinzer, S.1    Wörz, S.2    Kalla, C.3    Rohr, K.4    Weiss, M.5
  • 8
    • 39149086740 scopus 로고    scopus 로고
    • Assembly, organization, and function of the COPII coat
    • H Hughes DJ Stephens 2008 Assembly, organization, and function of the COPII coat Histochem Cell Biol 129 129
    • (2008) Histochem Cell Biol , vol.129 , pp. 129
    • Hughes, H.1    Stephens, D.J.2
  • 10
    • 34548683666 scopus 로고    scopus 로고
    • Comparison of a high-speed camera and a quadrant detector for measuring displacements in optical tweezers
    • S Keen J Leach G Gibson MJ Padgett 2007 Comparison of a high-speed camera and a quadrant detector for measuring displacements in optical tweezers J Opt A Pure Appl Opt 9 S264
    • (2007) J Opt a Pure Appl Opt , vol.9 , pp. 264
    • Keen, S.1    Leach, J.2    Gibson, G.3    Padgett, M.J.4
  • 12
    • 0037330690 scopus 로고    scopus 로고
    • Visualizing single molecules inside living cells using total internal reflection fluorescence microscopy
    • G Mashanov D Tacon AE Knight M Peckham JE Molloy 2003 Visualizing single molecules inside living cells using total internal reflection fluorescence microscopy Methods 29 142
    • (2003) Methods , vol.29 , pp. 142
    • Mashanov, G.1    Tacon, D.2    Knight, A.E.3    Peckham, M.4    Molloy, J.E.5
  • 16
    • 35248816828 scopus 로고    scopus 로고
    • Precise particle tracking against a complicated background: Polynomial fitting with Gaussian weight
    • SS Rogers TA Waigh X Zhao JR Lu 2007 Precise particle tracking against a complicated background: polynomial fitting with Gaussian weight Phys Biol 4 220
    • (2007) Phys Biol , vol.4 , pp. 220
    • Rogers, S.S.1    Waigh, T.A.2    Zhao, X.3    Lu, J.R.4
  • 18
    • 0037296519 scopus 로고    scopus 로고
    • De novo formation, fusion and fission of mammalian COPII-coated endoplasmic reticulum exit sites in mammalian cells
    • DJ Stephens 2003 De novo formation, fusion and fission of mammalian COPII-coated endoplasmic reticulum exit sites in mammalian cells EMBO Rep 4 210
    • (2003) EMBO Rep , vol.4 , pp. 210
    • Stephens, D.J.1
  • 19
    • 0036231415 scopus 로고    scopus 로고
    • Prescise nanometer localization analysis for individual fluorescent probes
    • RE Thompson DR Larson WW Webb 2002 Prescise nanometer localization analysis for individual fluorescent probes Biophys J 82 2775
    • (2002) Biophys J , vol.82 , pp. 2775
    • Thompson, R.E.1    Larson, D.R.2    Webb, W.W.3
  • 21
    • 23744499004 scopus 로고    scopus 로고
    • Fluorescence imaging with one nanometer accuracy: Application to molecular motors
    • A Yildiz PR Selvin 2005 Fluorescence imaging with one nanometer accuracy: application to molecular motors Acc Chem Res 38 574
    • (2005) Acc Chem Res , vol.38 , pp. 574
    • Yildiz, A.1    Selvin, P.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.