메뉴 건너뛰기




Volumn 28, Issue 3, 2008, Pages 646-654

Double-reference cross-correlation algorithm for separation of the arteries and veins from 3D MRA time series

Author keywords

Artery vein separation; Contrast enhanced MRA; Correlation; Fistula detection

Indexed keywords

CONTRAST MEDIUM;

EID: 51449114651     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21499     Document Type: Article
Times cited : (13)

References (22)
  • 2
    • 0031810805 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography: Theory and optimization
    • Prince MR. Contrast-enhanced MR angiography: theory and optimization. Magn Reson Imaging Clin N Am 1998;6:257-267.
    • (1998) Magn Reson Imaging Clin N Am , vol.6 , pp. 257-267
    • Prince, M.R.1
  • 3
    • 33745948819 scopus 로고    scopus 로고
    • Expanding role of MR angiography in clinical practice
    • Prince MR, Meaney JF. Expanding role of MR angiography in clinical practice. Eur Radiol 2006;16(Suppl 2):B3-8.
    • (2006) Eur Radiol , vol.16 , Issue.SUPPL. 2
    • Prince, M.R.1    Meaney, J.F.2
  • 4
    • 0032707725 scopus 로고    scopus 로고
    • Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: Basic experiments and clinical evaluation
    • Naganawa S, Ito T, Iwayama E, et al. Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: basic experiments and clinical evaluation. J Magn Reson Imaging 1999;10:813-820.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 813-820
    • Naganawa, S.1    Ito, T.2    Iwayama, E.3
  • 5
    • 33646684312 scopus 로고    scopus 로고
    • Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: Initial experience
    • Meckel S, Mekle R, Taschner C, et al. Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience. Neuroradiology 2006;48:291-299.
    • (2006) Neuroradiology , vol.48 , pp. 291-299
    • Meckel, S.1    Mekle, R.2    Taschner, C.3
  • 6
    • 0034101348 scopus 로고    scopus 로고
    • Cerebral dural arteriovenous fistulas: Detection by dynamic MR projection angiography
    • Wetzel SG, Bilecen D, Lyrer P, et al. Cerebral dural arteriovenous fistulas: detection by dynamic MR projection angiography. AJR Am J Roentgenol 2000;174:1293-1295.
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 1293-1295
    • Wetzel, S.G.1    Bilecen, D.2    Lyrer, P.3
  • 7
    • 0033860019 scopus 로고    scopus 로고
    • MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas
    • Aoki S, Yoshikawa T, Hori M, et al. MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas. AJR Am J Roentgenol 2000;175:451-453.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 451-453
    • Aoki, S.1    Yoshikawa, T.2    Hori, M.3
  • 8
    • 4444225987 scopus 로고    scopus 로고
    • Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: Initial experience
    • Tsuchiya K, Aoki C, Fujikawa A, Hachiya J. Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience. Eur Radiol 2004;14:1494-1497.
    • (2004) Eur Radiol , vol.14 , pp. 1494-1497
    • Tsuchiya, K.1    Aoki, C.2    Fujikawa, A.3    Hachiya, J.4
  • 9
    • 16844380763 scopus 로고    scopus 로고
    • Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: A technical note
    • Ziyeh S, Strecker R, Bertis A, Weber J, Klisch J, Mader I. Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note. AJNR Am J Neuroradiol 2005;26:630-634.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 630-634
    • Ziyeh, S.1    Strecker, R.2    Bertis, A.3    Weber, J.4    Klisch, J.5    Mader, I.6
  • 10
    • 0347511998 scopus 로고    scopus 로고
    • Intracranial dural arteriovenous fistulas: Evaluation with combined 3D time-of-flight MR angiography and MR digital subtraction angiography
    • Noguchi K, Melhem ER, Kanazawa T, Kubo M, Kuwayama N, Seto H. Intracranial dural arteriovenous fistulas: evaluation with combined 3D time-of-flight MR angiography and MR digital subtraction angiography. AJR Am J Roentgenol 2004;182:183-190.
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 183-190
    • Noguchi, K.1    Melhem, E.R.2    Kanazawa, T.3    Kubo, M.4    Kuwayama, N.5    Seto, H.6
  • 11
    • 34248682691 scopus 로고    scopus 로고
    • MR angiography of dural arteriovenous fistulas: Diagnosis and follow-up after treatment using a time-resolved 3D contrast-enhanced technique
    • Meckel S, Maier M, Ruiz DS, et al. MR angiography of dural arteriovenous fistulas: diagnosis and follow-up after treatment using a time-resolved 3D contrast-enhanced technique. AJNR Am J Neuroradiol 2007;28:877-884.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 877-884
    • Meckel, S.1    Maier, M.2    Ruiz, D.S.3
  • 12
    • 0034005783 scopus 로고    scopus 로고
    • Separation of arteries and veins in 3D MR angiography using correlation analysis
    • Bock M, Schoenberg SO, Floemer F, Schad LR. Separation of arteries and veins in 3D MR angiography using correlation analysis. Magn Reson Med 2000;43:481-487.
    • (2000) Magn Reson Med , vol.43 , pp. 481-487
    • Bock, M.1    Schoenberg, S.O.2    Floemer, F.3    Schad, L.R.4
  • 13
    • 0038122922 scopus 로고    scopus 로고
    • 3DVIEWNIX-AVS: A software package for the separate visualization of arteries and veins in CE-MRA images
    • Lei T, Udupa JK, Odhner D, Nyul LG, Saha PK. 3DVIEWNIX-AVS: a software package for the separate visualization of arteries and veins in CE-MRA images. Comput Med Imaging Graph 2003;27:351-362.
    • (2003) Comput Med Imaging Graph , vol.27 , pp. 351-362
    • Lei, T.1    Udupa, J.K.2    Odhner, D.3    Nyul, L.G.4    Saha, P.K.5
  • 14
    • 0035413308 scopus 로고    scopus 로고
    • Artery-vein separation via MRA - an image processing approach
    • Lei T, Udupa JK, Saha PK, Odhner D. Artery-vein separation via MRA - an image processing approach. IEEE Trans Med Imaging 2001;20:689-703.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 689-703
    • Lei, T.1    Udupa, J.K.2    Saha, P.K.3    Odhner, D.4
  • 15
    • 0036232421 scopus 로고    scopus 로고
    • 3D MRA visualization and artery-vein separation using blood-pool contrast agent MS-325
    • Lei T, Udupa JK, Saha PK, et al. 3D MRA visualization and artery-vein separation using blood-pool contrast agent MS-325. Acad Radiol 2002;9(Suppl 1):S127-133.
    • (2002) Acad Radiol , vol.9 , Issue.SUPPL. 1
    • Lei, T.1    Udupa, J.K.2    Saha, P.K.3
  • 16
    • 0037406526 scopus 로고    scopus 로고
    • Separating arterial and venous components from 3D dynamic contrast-enhanced MRI studies using factor analysis
    • Martel AL, Fraser D, Delay GS, Morgan PS, Moody AR. Separating arterial and venous components from 3D dynamic contrast-enhanced MRI studies using factor analysis. Magn Reson Med 2003;49:928-933.
    • (2003) Magn Reson Med , vol.49 , pp. 928-933
    • Martel, A.L.1    Fraser, D.2    Delay, G.S.3    Morgan, P.S.4    Moody, A.R.5
  • 17
    • 0034927790 scopus 로고    scopus 로고
    • Highly automated segmentation of arterial and venous trees from three-dimensional magnetic resonance angiography (MRA)
    • Stefancik RM, Sonka M. Highly automated segmentation of arterial and venous trees from three-dimensional magnetic resonance angiography (MRA). Int J Cardiovasc Imaging 2001;17:37-47.
    • (2001) Int J Cardiovasc Imaging , vol.17 , pp. 37-47
    • Stefancik, R.M.1    Sonka, M.2
  • 18
    • 0036198869 scopus 로고    scopus 로고
    • Segmentation with gray-scale connectedness can separate arteries and veins in MRA
    • Tizon X, Smedby O. Segmentation with gray-scale connectedness can separate arteries and veins in MRA. J Magn Reson Imaging 2002;15:438-445.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 438-445
    • Tizon, X.1    Smedby, O.2
  • 20
    • 0348141986 scopus 로고    scopus 로고
    • Optimized assessment of hand vascularization on contrast-enhanced MR angiography with a subsystolic continuous compression technique
    • Bilecen D, Aschwanden M, Heidecker HG, Bongartz G. Optimized assessment of hand vascularization on contrast-enhanced MR angiography with a subsystolic continuous compression technique. AJR Am J Roentgenol 2004;182:180-182.
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 180-182
    • Bilecen, D.1    Aschwanden, M.2    Heidecker, H.G.3    Bongartz, G.4
  • 21
    • 51449097458 scopus 로고    scopus 로고
    • Automatic segmentation of contrast-enhanced time resolved image series
    • Kim J, Zabih R. Automatic segmentation of contrast-enhanced time resolved image series. J X-Ray Sci Technol 2000;9:1-11.
    • (2000) J X-Ray Sci Technol , vol.9 , pp. 1-11
    • Kim, J.1    Zabih, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.