메뉴 건너뛰기




Volumn 16, Issue SUPPL. 2, 2006, Pages

Expanding role of MR angiography in clinical practice

Author keywords

Atherosclerosis; Contrast agent; Gadofosveset trisodium; Gadolinium; MRA

Indexed keywords

CONTRAST MEDIUM;

EID: 33745948819     PISSN: 16133749     EISSN: 16133757     Source Type: Journal    
DOI: 10.1007/s10406-006-0161-x     Document Type: Review
Times cited : (44)

References (31)
  • 1
    • 84945400412 scopus 로고    scopus 로고
    • Health risks from exposure to low levels of ionizing radiation: BEIR VII-Phase 2
    • BEIR
    • BEIR (2005) Health risks from exposure to low levels of ionizing radiation: BEIR VII-Phase 2: Nat Acad Sci
    • (2005) Nat Acad Sci
  • 3
    • 0034663426 scopus 로고    scopus 로고
    • Breast cancer mortality after diagnostic radiography: Findings from the US Scoliosis Cohort Study
    • Morin Doody M, Lonstein JE, Stovall M, Hacker DG, Luckyanov N, Land CE (2000) Breast cancer mortality after diagnostic radiography: findings from the US Scoliosis Cohort Study. Spine 25:2052-2063
    • (2000) Spine , vol.25 , pp. 2052-2063
    • Morin Doody, M.1    Lonstein, J.E.2    Stovall, M.3    Hacker, D.G.4    Luckyanov, N.5    Land, C.E.6
  • 4
    • 0346688606 scopus 로고    scopus 로고
    • Effect of low doses of ionising radiation in infancy on cognitive function in adulthood: Swedish population-based cohort study
    • Hall P, Adami HO, Trichopoulos D et al. (2004) Effect of low doses of ionising radiation in infancy on cognitive function in adulthood: Swedish population-based cohort study. BMJ 328:19
    • (2004) BMJ , vol.328 , pp. 19
    • Hall, P.1    Adami, H.O.2    Trichopoulos, D.3
  • 5
    • 0036934964 scopus 로고    scopus 로고
    • FDA public health notification: Reducing radiation risk from computed tomography for pediatric and small adult patients
    • FDA
    • FDA (2002) FDA public health notification: reducing radiation risk from computed tomography for pediatric and small adult patients. Pediatr Radiol 32:314-316
    • (2002) Pediatr Radiol , vol.32 , pp. 314-316
  • 6
    • 77956032955 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic X-rays
    • Brenner DJ, Hall EJ (2004) Risk of cancer from diagnostic X-rays. Lancet 363:2192
    • (2004) Lancet , vol.363 , pp. 2192
    • Brenner, D.J.1    Hall, E.J.2
  • 7
    • 23644461603 scopus 로고    scopus 로고
    • Lack of radiological awareness among physicians working in a tertiary-care cardiological centre
    • Correia MJ, Hellies A, Andreassi MG, Ghelarducci B, Picano E (2005) Lack of radiological awareness among physicians working in a tertiary-care cardiological centre. Int J Cardiol 103:307-311
    • (2005) Int J Cardiol , vol.103 , pp. 307-311
    • Correia, M.J.1    Hellies, A.2    Andreassi, M.G.3    Ghelarducci, B.4    Picano, E.5
  • 8
    • 72449120075 scopus 로고    scopus 로고
    • Radiation effects in fluoroscopically guided cardiac interventions- keeping them under control
    • Rehani MM, Ortiz-Lopez P (2005) Radiation effects in fluoroscopically guided cardiac interventions-keeping them under control. Int J Cardiol
    • (2005) Int J Cardiol
    • Rehani, M.M.1    Ortiz-Lopez, P.2
  • 10
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR 176:289-296
    • (2001) AJR , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 11
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t Sense: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesinger P, Pruessman KP (2003) k-t BLAST and k-t Sense: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 50:1031-1043
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1043
    • Tsao, J.1    Boesinger, P.2    Pruessman, K.P.3
  • 12
    • 11144284746 scopus 로고    scopus 로고
    • Comparison of radial and Cartesian imaging techniques for MR coronary angiography
    • Jahnke C, Paetsch I, Schnackenburg B et al. (2004) Comparison of radial and Cartesian imaging techniques for MR coronary angiography. J Cardiovasc Magn Reson 6:865-875
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 865-875
    • Jahnke, C.1    Paetsch, I.2    Schnackenburg, B.3
  • 13
    • 18244400728 scopus 로고    scopus 로고
    • Free-breathing renal magnetic resonance angiography with steady-state free-precession and slab-selective spin inversion combined with radial k-space sampling and water-selective excitation
    • Katoh M, Spuentrup E, Stuber M, Hoogeveen R, Gunther RW, Buecker A (2005) Free-breathing renal magnetic resonance angiography with steady-state free-precession and slab-selective spin inversion combined with radial k-space sampling and water-selective excitation. Magn Reson Med 53:1228-1233
    • (2005) Magn Reson Med , vol.53 , pp. 1228-1233
    • Katoh, M.1    Spuentrup, E.2    Stuber, M.3    Hoogeveen, R.4    Gunther, R.W.5    Buecker, A.6
  • 14
    • 0036708131 scopus 로고    scopus 로고
    • Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels
    • Du J, Carroll TJ, Wagner HJ et al. (2002) Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels. Magn Reson Med 48:516-522
    • (2002) Magn Reson Med , vol.48 , pp. 516-522
    • Du, J.1    Carroll, T.J.2    Wagner, H.J.3
  • 15
    • 0036322910 scopus 로고    scopus 로고
    • Three-dimensional spiral MR imaging: Application to renal multiphase contrast-enhanced angiography
    • Amann M, Bock M, Floemer F, Schoenberg SO, Schad LR (2002) Three-dimensional spiral MR imaging: application to renal multiphase contrast-enhanced angiography. Magn Re-son Med 48:290-296
    • (2002) Magn Re-son Med , vol.48 , pp. 290-296
    • Amann, M.1    Bock, M.2    Floemer, F.3    Schoenberg, S.O.4    Schad, L.R.5
  • 17
    • 0036789099 scopus 로고    scopus 로고
    • Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels
    • Swan JS, Carroll TJ, Kennell TW et al. (2002) Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels. Radiology 225:43-52
    • (2002) Radiology , vol.225 , pp. 43-52
    • Swan, J.S.1    Carroll, T.J.2    Kennell, T.W.3
  • 18
    • 4744357467 scopus 로고    scopus 로고
    • Time-resolved 3D MR angiog-raphy of the abdomen with a real-time system
    • Wieben O, Grist TM, Hany TF et al. (2004) Time-resolved 3D MR angiog-raphy of the abdomen with a real-time system. Magn Reson Med 52:921-926
    • (2004) Magn Reson Med , vol.52 , pp. 921-926
    • Wieben, O.1    Grist, T.M.2    Hany, T.F.3
  • 19
    • 10644244513 scopus 로고    scopus 로고
    • High-resolution time-resolved contrast-enhanced 3D MRA by combining SENSE with keyhole and SLAM strategies
    • Wu Y, Goodrich KC, Buswell HR, Katzman GL, Parker DL (2004) High-resolution time-resolved contrast-enhanced 3D MRA by combining SENSE with keyhole and SLAM strategies. Magn Reson Imaging 22:1161-1168
    • (2004) Magn Reson Imaging , vol.22 , pp. 1161-1168
    • Wu, Y.1    Goodrich, K.C.2    Buswell, H.R.3    Katzman, G.L.4    Parker, D.L.5
  • 20
    • 72449143835 scopus 로고    scopus 로고
    • Spiral magnetic resonance coronary angiography with rapid realtime localization
    • Yang PC, Meyer CH, Terashima M et al. (2003) Spiral magnetic resonance coronary angiography with rapid realtime localization. J Am Coll Cardiol 2:7
    • (2003) J Am Coll Cardiol , vol.2 , pp. 7
    • Yang, P.C.1    Meyer, C.H.2    Terashima, M.3
  • 21
    • 4644262669 scopus 로고    scopus 로고
    • High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction
    • Zhu H, Buck DG, Zhang Z et al. (2004) High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction. Magn Reson Med 52:14-18
    • (2004) Magn Reson Med , vol.52 , pp. 14-18
    • Zhu, H.1    Buck, D.G.2    Zhang, Z.3
  • 22
    • 10144256538 scopus 로고    scopus 로고
    • Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction
    • Wang Y, Johnston DL, Breen JF et al. (1996) Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction. Magn Reson Med 36:551-556
    • (1996) Magn Reson Med , vol.36 , pp. 551-556
    • Wang, Y.1    Johnston, D.L.2    Breen, J.F.3
  • 23
    • 4944229996 scopus 로고    scopus 로고
    • Projection imaging of the right coronary artery with an intravenous injection of contrast agent
    • Green JD, Schirf BE, Omary RA, McCarthy RM, Carr JC, Li D (2004) Projection imaging of the right coronary artery with an intravenous injection of contrast agent. Magn Reson Med 52:699-703
    • (2004) Magn Reson Med , vol.52 , pp. 699-703
    • Green, J.D.1    Schirf, B.E.2    Omary, R.A.3    McCarthy, R.M.4    Carr, J.C.5    Li, D.6
  • 25
    • 0032051645 scopus 로고    scopus 로고
    • In vitro model of arterial stenosis: Correlation of MR signal dephasing and trans-stenotic pressure gradients
    • Mustert BR, Williams DM, Prince MR (1998) In vitro model of arterial stenosis: correlation of MR signal dephasing and trans-stenotic pressure gradients. Magn Reson Imaging 16:301-310
    • (1998) Magn Reson Imaging , vol.16 , pp. 301-310
    • Mustert, B.R.1    Williams, D.M.2    Prince, M.R.3
  • 26
    • 0031930199 scopus 로고    scopus 로고
    • Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging
    • Niendorf ER, Grist TM, Lee FT, Brazy PC, Santyr GE (1998) Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging. Radiology 206
    • (1998) Radiology , vol.206
    • Niendorf, E.R.1    Grist, T.M.2    Lee, F.T.3    Brazy, P.C.4    Santyr, G.E.5
  • 27
    • 0035820272 scopus 로고    scopus 로고
    • Rapid magnetic resonance angiography for detection of atherosclerosis
    • Ruehm SG, Goyen M, Barkhausen J et al. (2001) Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 357:1086-1091
    • (2001) Lancet , vol.357 , pp. 1086-1091
    • Ruehm, S.G.1    Goyen, M.2    Barkhausen, J.3
  • 29
    • 3242800345 scopus 로고    scopus 로고
    • Chronic pulmonary embolism: Combining MR angiography with functional assessment
    • Prince MR, Alderson PO, Sostman HD (2004) Chronic pulmonary embolism: combining MR angiography with functional assessment. Radiology 232:325-326
    • (2004) Radiology , vol.232 , pp. 325-326
    • Prince, M.R.1    Alderson, P.O.2    Sostman, H.D.3
  • 30
    • 0032868437 scopus 로고    scopus 로고
    • Comparison of three dimensional magnetic resonance imaging in conjunction with a blood pool contrast agent and nuclear scintigraphy for the detection of experimentally induced gastrointestinal bleeding
    • Hilfiker PR, Weishaupt D, Kacl GM et al. (1999) Comparison of three dimensional magnetic resonance imaging in conjunction with a blood pool contrast agent and nuclear scintigraphy for the detection of experimentally induced gastrointestinal bleeding. Gut 45:581-587
    • (1999) Gut , vol.45 , pp. 581-587
    • Hilfiker, P.R.1    Weishaupt, D.2    Kacl, G.M.3
  • 31
    • 1942533397 scopus 로고    scopus 로고
    • Blood pool MR angiogra-phy of aortic stent-graft endoleak
    • Ersoy H, Jacobs P, Kent CK, Prince MR (2004) Blood pool MR angiogra-phy of aortic stent-graft endoleak. AJR 182:1181-1186
    • (2004) AJR , vol.182 , pp. 1181-1186
    • Ersoy, H.1    Jacobs, P.2    Kent, C.K.3    Prince, M.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.