메뉴 건너뛰기




Volumn 15, Issue 10, 2008, Pages 1316-1321

Sonographically-guided Metallic Marker Placement at Time of Wire Localization for Intraductal or Cystic Lesions. A Method to Verify Lesion Retrieval

Author keywords

Breast; breast specimens; mammography; sonography

Indexed keywords

ADULT; AGED; ARTICLE; BREAST BIOPSY; CLINICAL ARTICLE; CONTROLLED STUDY; ECHOGRAPHY; FIBROCYSTIC BREAST DISEASE; HUMAN; MAMMOGRAPHY; PRIORITY JOURNAL; RADIODIAGNOSIS;

EID: 51249099171     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2008.03.020     Document Type: Article
Times cited : (4)

References (33)
  • 1
    • 0030749032 scopus 로고    scopus 로고
    • Needle-localized breast biopsy: why do we fail?
    • Jackman R.J., and Marzoni Jr. F.A. Needle-localized breast biopsy: why do we fail?. Radiology 204 (1997) 677-684
    • (1997) Radiology , vol.204 , pp. 677-684
    • Jackman, R.J.1    Marzoni Jr., F.A.2
  • 2
    • 0032086616 scopus 로고    scopus 로고
    • Missed rates for surgical biopsy of needle-localized breast lesions
    • Hall F.M. Missed rates for surgical biopsy of needle-localized breast lesions. Radiology 207 (1998) 832
    • (1998) Radiology , vol.207 , pp. 832
    • Hall, F.M.1
  • 3
    • 33646919227 scopus 로고    scopus 로고
    • Sonography of postexcision specimens of nonpalpable breast lesions: value, limitations, and description of a method
    • Mesurolle B., El-Khoury M., Hori D., et al. Sonography of postexcision specimens of nonpalpable breast lesions: value, limitations, and description of a method. Am J Roentgenol 186 (2006) 1014-1024
    • (2006) Am J Roentgenol , vol.186 , pp. 1014-1024
    • Mesurolle, B.1    El-Khoury, M.2    Hori, D.3
  • 5
    • 0028142627 scopus 로고
    • Localization of impalpable breast masses: value of sonography in the operating room and scanning of excised specimens
    • Fornage B.D., Ross M.I., Singletary S.E., et al. Localization of impalpable breast masses: value of sonography in the operating room and scanning of excised specimens. Am J Roentgenol 163 (1994) 569-573
    • (1994) Am J Roentgenol , vol.163 , pp. 569-573
    • Fornage, B.D.1    Ross, M.I.2    Singletary, S.E.3
  • 6
    • 0036084056 scopus 로고    scopus 로고
    • Ultrasonic specimen radiography for non-palpable breast lesions
    • Vujovic P., Gianduzzo T., Archibald C., et al. Ultrasonic specimen radiography for non-palpable breast lesions. Breast 11 (2002) 144-150
    • (2002) Breast , vol.11 , pp. 144-150
    • Vujovic, P.1    Gianduzzo, T.2    Archibald, C.3
  • 7
    • 0028260832 scopus 로고
    • Ultrasonographically guided wire localization of nonpalpable breast lesions
    • Rissanen T.J., Makarainen H.P., Kiviniemi H.O., et al. Ultrasonographically guided wire localization of nonpalpable breast lesions. J Ultrasound Med 13 (1994) 183-188
    • (1994) J Ultrasound Med , vol.13 , pp. 183-188
    • Rissanen, T.J.1    Makarainen, H.P.2    Kiviniemi, H.O.3
  • 8
    • 84890179200 scopus 로고    scopus 로고
    • National Comprehensive Cancer Network Accessed on June 4, 2008.
    • National Comprehensive Cancer Network. Breast Cancer Screening and Diagnosis Guidelines (v.1.2007). http://www.nccn.org/professionals/physician_gls/PDF/breast-screening.pdf Accessed on June 4, 2008.
    • Breast Cancer Screening and Diagnosis Guidelines (v.1.2007)
  • 9
    • 0027316207 scopus 로고
    • US-guided automated large core breast biopsy
    • Parker S.H., Jobe W.E., Dennis M.A., et al. US-guided automated large core breast biopsy. Radiology 187 (1993) 507-511
    • (1993) Radiology , vol.187 , pp. 507-511
    • Parker, S.H.1    Jobe, W.E.2    Dennis, M.A.3
  • 10
    • 37549067008 scopus 로고    scopus 로고
    • Sonographically guided 14 gauge core needle biopsy of breast masses: a review of 2420 cases with long-term follow-up
    • Youk J.H., Kim E.K., Kim M.J., et al. Sonographically guided 14 gauge core needle biopsy of breast masses: a review of 2420 cases with long-term follow-up. Am J Roentgenol 190 (2008) 202-207
    • (2008) Am J Roentgenol , vol.190 , pp. 202-207
    • Youk, J.H.1    Kim, E.K.2    Kim, M.J.3
  • 11
    • 0034094967 scopus 로고    scopus 로고
    • Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results
    • Simon J.R., Kalbhen C.L., Cooper R.A., et al. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 215 (2000) 694-697
    • (2000) Radiology , vol.215 , pp. 694-697
    • Simon, J.R.1    Kalbhen, C.L.2    Cooper, R.A.3
  • 12
    • 33847154999 scopus 로고    scopus 로고
    • Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases
    • Cassano E., Uban L.A.B.D., Pizzamiglio M., et al. Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 1022 (2007) 103-110
    • (2007) Breast Cancer Res Treat , vol.1022 , pp. 103-110
    • Cassano, E.1    Uban, L.A.B.D.2    Pizzamiglio, M.3
  • 13
    • 0035189329 scopus 로고    scopus 로고
    • Sonographically guided directional vacuum-assisted breast biopsy: preliminary experience in Venezuela
    • Perez-Fuentes J.A., Longobardi I.R., Acosta V.F., et al. Sonographically guided directional vacuum-assisted breast biopsy: preliminary experience in Venezuela. Am J Roentgenol 177 (2001) 1459-1463
    • (2001) Am J Roentgenol , vol.177 , pp. 1459-1463
    • Perez-Fuentes, J.A.1    Longobardi, I.R.2    Acosta, V.F.3
  • 14
    • 0037306907 scopus 로고    scopus 로고
    • Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast
    • Philpotts L.E., Hooley R.J., and Lee C.H. Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. Am J Roentgenol 180 (2003) 347-351
    • (2003) Am J Roentgenol , vol.180 , pp. 347-351
    • Philpotts, L.E.1    Hooley, R.J.2    Lee, C.H.3
  • 15
    • 0034055214 scopus 로고    scopus 로고
    • Incidental treatment of nipple discharge caused by benign intraductal papilloma through diagnostic mammotome biopsy
    • Dennis M.A., Parker S., Kaske T.I., et al. Incidental treatment of nipple discharge caused by benign intraductal papilloma through diagnostic mammotome biopsy. Am J Roentgenol 174 (2000) 1263-1268
    • (2000) Am J Roentgenol , vol.174 , pp. 1263-1268
    • Dennis, M.A.1    Parker, S.2    Kaske, T.I.3
  • 16
    • 0033755201 scopus 로고    scopus 로고
    • Sonographically guided metallic clip placement after core needle biopsy of the breast
    • Phillips S.W., Gabriel H., Comstock C.E., et al. Sonographically guided metallic clip placement after core needle biopsy of the breast. Am J Roentgenol 175 (2000) 1353-1355
    • (2000) Am J Roentgenol , vol.175 , pp. 1353-1355
    • Phillips, S.W.1    Gabriel, H.2    Comstock, C.E.3
  • 17
    • 0030671379 scopus 로고    scopus 로고
    • Clip placement after stereotactic vacuum-assisted breast biopsy
    • Liberman L., Dershaw D., Morris E.A., et al. Clip placement after stereotactic vacuum-assisted breast biopsy. Radiology 205 (1997) 417-422
    • (1997) Radiology , vol.205 , pp. 417-422
    • Liberman, L.1    Dershaw, D.2    Morris, E.A.3
  • 18
    • 0032871647 scopus 로고    scopus 로고
    • Usefulness of tissue marker clips in patients undergoing neoadjuvant chemotherapy for breast cancer
    • Dash N., Chafin S.H., Johnson R.R., et al. Usefulness of tissue marker clips in patients undergoing neoadjuvant chemotherapy for breast cancer. Am J Roentgenol 173 (1999) 911-917
    • (1999) Am J Roentgenol , vol.173 , pp. 911-917
    • Dash, N.1    Chafin, S.H.2    Johnson, R.R.3
  • 19
    • 6344252203 scopus 로고    scopus 로고
    • American College of Radiology, American College of Radiology, Reston, VA
    • American College of Radiology. Breast imaging reporting and data system. 4th ed. (2003), American College of Radiology, Reston, VA
    • (2003) Breast imaging reporting and data system. 4th ed.
  • 20
    • 0038689339 scopus 로고    scopus 로고
    • Factor predicting successful needle-localized breast biopsy
    • Abrahamson P.E., Dunlap L.A., Amamoo A., et al. Factor predicting successful needle-localized breast biopsy. Acad Radiol 10 (2003) 601-606
    • (2003) Acad Radiol , vol.10 , pp. 601-606
    • Abrahamson, P.E.1    Dunlap, L.A.2    Amamoo, A.3
  • 21
    • 2942729845 scopus 로고    scopus 로고
    • Cost minimization study of image-guided core biopsy versus surgical excisional biopsy for women with abnormal mammograms
    • Golub R.M., Bennett C.L., Stinson T., et al. Cost minimization study of image-guided core biopsy versus surgical excisional biopsy for women with abnormal mammograms. J Clin Oncol 22 (2004) 2430-2437
    • (2004) J Clin Oncol , vol.22 , pp. 2430-2437
    • Golub, R.M.1    Bennett, C.L.2    Stinson, T.3
  • 22
    • 0034985368 scopus 로고    scopus 로고
    • Impact of core-needle biopsy on the surgical management of mammographic abnormalities
    • White R.R., Halperin T.J., Olson J.A., et al. Impact of core-needle biopsy on the surgical management of mammographic abnormalities. Ann Surg 233 (2001) 769-777
    • (2001) Ann Surg , vol.233 , pp. 769-777
    • White, R.R.1    Halperin, T.J.2    Olson, J.A.3
  • 23
    • 0036789797 scopus 로고    scopus 로고
    • Three- to six year follow-up for 379 benign image-guided large core needle biopsies of nonpalpable breast abnormalities
    • Acheson M.B., Patton R.G., Howisey R.L., et al. Three- to six year follow-up for 379 benign image-guided large core needle biopsies of nonpalpable breast abnormalities. J Am Coll Surg 195 (2002) 462-466
    • (2002) J Am Coll Surg , vol.195 , pp. 462-466
    • Acheson, M.B.1    Patton, R.G.2    Howisey, R.L.3
  • 24
    • 33748439243 scopus 로고    scopus 로고
    • Should all breast cancers be diagnosed by needle biopsy?
    • Lannin D.R., Ponn T., Andrejeva L., et al. Should all breast cancers be diagnosed by needle biopsy?. Am J Surg 192 (2006) 450-454
    • (2006) Am J Surg , vol.192 , pp. 450-454
    • Lannin, D.R.1    Ponn, T.2    Andrejeva, L.3
  • 25
    • 0037369149 scopus 로고    scopus 로고
    • Stereotactic histologic biopsy with patients prone: technical feasibility in 98% of mammographically detected lesions
    • Jackman R.J., and Marzoni Jr. F.A. Stereotactic histologic biopsy with patients prone: technical feasibility in 98% of mammographically detected lesions. Am J Roentgenol 180 (2003) 785-794
    • (2003) Am J Roentgenol , vol.180 , pp. 785-794
    • Jackman, R.J.1    Marzoni Jr., F.A.2
  • 26
    • 0028997325 scopus 로고
    • Breast tumors associated with nipple discharge correlation of findings on galactography and sonography
    • Chung S.Y., Lee K.W., Park K.S., et al. Breast tumors associated with nipple discharge correlation of findings on galactography and sonography. Clin Imaging 19 (1995) 165-171
    • (1995) Clin Imaging , vol.19 , pp. 165-171
    • Chung, S.Y.1    Lee, K.W.2    Park, K.S.3
  • 27
    • 33745570080 scopus 로고    scopus 로고
    • Role of radiologic features in the management of papillary lesions of the breast
    • Lam W.W.M., Chu W.C.W., Tang A.P.Y., et al. Role of radiologic features in the management of papillary lesions of the breast. Am J Roentgenol 186 (2006) 1322-1327
    • (2006) Am J Roentgenol , vol.186 , pp. 1322-1327
    • Lam, W.W.M.1    Chu, W.C.W.2    Tang, A.P.Y.3
  • 28
    • 33745572727 scopus 로고    scopus 로고
    • is surgical excision warranted after benign, concordant diagnosis of papilloma at percutaneous breast biopsy?
    • Liberman L., Tornos C., Huzjan R., et al. is surgical excision warranted after benign, concordant diagnosis of papilloma at percutaneous breast biopsy?. Am J Roentgenol 186 (2006) 1328-1334
    • (2006) Am J Roentgenol , vol.186 , pp. 1328-1334
    • Liberman, L.1    Tornos, C.2    Huzjan, R.3
  • 29
    • 33344456858 scopus 로고    scopus 로고
    • Papillary lesions of the breast at percutaneous core-needle biopsy
    • Mercado C.L., Hamele-Bena D., Oken S.M., et al. Papillary lesions of the breast at percutaneous core-needle biopsy. Radiology 238 (2006) 801-808
    • (2006) Radiology , vol.238 , pp. 801-808
    • Mercado, C.L.1    Hamele-Bena, D.2    Oken, S.M.3
  • 30
    • 4444275728 scopus 로고    scopus 로고
    • Image-guided breast biopsy and management of high-risk lesions
    • Berg W. Image-guided breast biopsy and management of high-risk lesions. Radiol Clin N Am 42 (2004) 935-946
    • (2004) Radiol Clin N Am , vol.42 , pp. 935-946
    • Berg, W.1
  • 31
    • 0036817964 scopus 로고    scopus 로고
    • Wire localization of non-palpable breast lesions: out of date?
    • Ernst M.F., Avenarius A., Schur K.H., et al. Wire localization of non-palpable breast lesions: out of date?. Breast 11 (2002) 408-413
    • (2002) Breast , vol.11 , pp. 408-413
    • Ernst, M.F.1    Avenarius, A.2    Schur, K.H.3
  • 32
    • 0020317257 scopus 로고
    • Nonpalpble breast lesions: mammographic wire-guided biopsy and radiologic-histologic correlation
    • Blichert-Toft M., Dyreborg U., et al. Nonpalpble breast lesions: mammographic wire-guided biopsy and radiologic-histologic correlation. World J Surg 2 (1982) 119-125
    • (1982) World J Surg , vol.2 , pp. 119-125
    • Blichert-Toft, M.1    Dyreborg, U.2
  • 33
    • 0025298631 scopus 로고
    • An alternative approach to nonpalpable breast biopsies
    • Reid S.E., Scanlon E.F., Bernstein J.R., et al. An alternative approach to nonpalpable breast biopsies. J Surg Oncol 44 (1990) 3-96
    • (1990) J Surg Oncol , vol.44 , pp. 3-96
    • Reid, S.E.1    Scanlon, E.F.2    Bernstein, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.