메뉴 건너뛰기




Volumn 11, Issue 5, 2002, Pages 408-413

Wire localization of non-palpable breast lesions: Out of date?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BREAST BIOPSY; BREAST CANCER; BREAST LESION; BREAST SURGERY; CANCER SCREENING; CONSERVATIVE TREATMENT; DENSITY; DIAGNOSTIC PROCEDURE; EXPERIENCE; FEASIBILITY STUDY; FEMALE; FOLLOW UP; GUIDE WIRE; HEMATOMA; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; MAMMOGRAPHY; NEEDLE BIOPSY; PALPATION; PRIORITY JOURNAL; RELIABILITY; RETROSPECTIVE STUDY; STANDARD; TUMOR LOCALIZATION; WOUND INFECTION;

EID: 0036817964     PISSN: 09609776     EISSN: None     Source Type: Journal    
DOI: 10.1054/brst.2002.0444     Document Type: Article
Times cited : (24)

References (30)
  • 1
    • 0032974778 scopus 로고    scopus 로고
    • Extent of lumpectomy for breast cancer after diagnosis by stereotactic core versus wire localization biopsy
    • Al-Shobi S S, Helvie M A, Pass H A, Chang A E. Extent of lumpectomy for breast cancer after diagnosis by stereotactic core versus wire localization biopsy. Ann Surg Oncol 1999; 6(4): 33-335.
    • (1999) Ann. Surg. Oncol. , vol.6 , Issue.4 , pp. 33-335
    • Al-Shobi, S.S.1    Helvie, M.A.2    Pass, H.A.3    Chang, A.E.4
  • 2
    • 0028181404 scopus 로고
    • 1991 national survey of carcinoma of the breast by the Commission on Cancer
    • Osteen R T, Cady B, Chmiel J S et al. 1991 national survey of carcinoma of the breast by the Commission on Cancer. J Am Coll Surg 1994; 3: 213-219.
    • (1994) J. Am. Coll. Surg. , vol.3 , pp. 213-219
    • Osteen, R.T.1    Cady, B.2    Chmiel, J.S.3
  • 3
    • 0026040330 scopus 로고
    • Preoperative localization and surgical approach in 344 cases of non-palpable breast lesions
    • Luini A, Sacchini V, Galimberti V et al. Preoperative localization and surgical approach in 344 cases of non-palpable breast lesions. Eur J Surg Oncol 1991; 17: 480-484.
    • (1991) Eur. J. Surg. Oncol. , vol.17 , pp. 480-484
    • Luini, A.1    Sacchini, V.2    Galimberti, V.3
  • 4
    • 0032734104 scopus 로고    scopus 로고
    • Role of wire-guided breast biopsy for diagnosis of malignant nonpalpable mammographic lesions
    • Lantsberg L, Kirshtein B, Koretz M, Strano S. Role of wire-guided breast biopsy for diagnosis of malignant nonpalpable mammographic lesions. World J Surg 1999; 23(12): 1279-1281.
    • (1999) World J. Surg. , vol.23 , Issue.12 , pp. 1279-1281
    • Lantsberg, L.1    Kirshtein, B.2    Koretz, M.3    Strano, S.4
  • 5
    • 0023109558 scopus 로고
    • Hooked-wire-directed breast biopsy and overpenetrated mammography
    • Silverstein M J, Gamagami P, Rosser R J et al. Hooked-wire-directed breast biopsy and overpenetrated mammography. Cancer 1987; 59: 715-722.
    • (1987) Cancer , vol.59 , pp. 715-722
    • Silverstein, M.J.1    Gamagami, P.2    Rosser, R.J.3
  • 6
    • 0034011038 scopus 로고    scopus 로고
    • Diagnostic accuracy of large -core needle biopsy for non-palpable breast disease: A meta-analysis
    • Verkooijen H M, Peeters P H M, Buskens E et al. Diagnostic accuracy of large -core needle biopsy for non-palpable breast disease: a meta-analysis. Br J Cancer 2000; 82: 1017-1021.
    • (2000) Br. J. Cancer , vol.82 , pp. 1017-1021
    • Verkooijen, H.M.1    Peeters, P.H.M.2    Buskens, E.3
  • 7
    • 0034059275 scopus 로고    scopus 로고
    • Diagnostic accuracy of needle-localized open breast biopsy for impalpable breast disease
    • Verkooijen H M, Peeters P H M, Pijnappel R M et al. Diagnostic accuracy of needle-localized open breast biopsy for impalpable breast disease. Br J Surg 2000; 87: 344-347.
    • (2000) Br. J. Surg. , vol.87 , pp. 344-347
    • Verkooijen, H.M.1    Peeters, P.H.M.2    Pijnappel, R.M.3
  • 8
    • 0032425538 scopus 로고    scopus 로고
    • A core breast biopsy diagnosis of invasive carcinoma allows for definitive surgical treatment planning
    • King T A, Cederbom G J, Champaign J L et al. A core breast biopsy diagnosis of invasive carcinoma allows for definitive surgical treatment planning. Am J Surg 1998; 176: 497-501.
    • (1998) Am. J. Surg. , vol.176 , pp. 497-501
    • King, T.A.1    Cederbom, G.J.2    Champaign, J.L.3
  • 9
    • 0029782851 scopus 로고    scopus 로고
    • Role of stereotactic breast biopsy
    • Bernstein J R. Role of stereotactic breast biopsy. Semin Surg Oncol 1996; 12: 290-299.
    • (1996) Semin. Surg. Oncol. , vol.12 , pp. 290-299
    • Bernstein, J.R.1
  • 10
    • 0032942889 scopus 로고    scopus 로고
    • Comparison of radioguided excision with wire localization of occult breast lesions
    • Luini A, Zurrida S, Paganelli G et al. Comparison of radioguided excision with wire localization of occult breast lesions. Br J Surg 1999; 86: 522-525.
    • (1999) Br. J. Surg. , vol.86 , pp. 522-525
    • Luini, A.1    Zurrida, S.2    Paganelli, G.3
  • 11
    • 0020600305 scopus 로고
    • Percutaneous localisation of non palpable breast lesions
    • Hermann G, Janus G, Lesnick G J. Percutaneous localisation of non palpable breast lesions. Breast 1983; 9: 4-6.
    • (1983) Breast , vol.9 , pp. 4-6
    • Hermann, G.1    Janus, G.2    Lesnick, G.J.3
  • 12
    • 0017065697 scopus 로고
    • Preoperative localization of nonpalpable breast lesions demonstrated by mammography
    • Frank H A, Hall F M, Steer M L. Preoperative localization of nonpalpable breast lesions demonstrated by mammography. N Engl J Med 1976; 295: 259-260.
    • (1976) N. Engl. J. Med. , vol.295 , pp. 259-260
    • Frank, H.A.1    Hall, F.M.2    Steer, M.L.3
  • 13
    • 0018317216 scopus 로고
    • Preoperative localization of nonpalpable breast lesions
    • Hall FM, Frank HA. Preoperative localization of nonpalpable breast lesions. Am J Roentgenol 1979; 132: 101-105.
    • (1979) Am. J. Roentgenol. , vol.132 , pp. 101-105
    • Hall, F.M.1    Frank, H.A.2
  • 14
    • 0018865637 scopus 로고
    • A modified needle-hookwire technique to simplify preoperative localization of occult breast lesions
    • De Kopans D B, Luca S. A modified needle-hookwire technique to simplify preoperative localization of occult breast lesions. Radiology 1980; 134: 781.
    • (1980) Radiology , vol.134 , pp. 781
    • De Kopans, D.B.1    Luca, S.2
  • 15
    • 0022352931 scopus 로고
    • Nonpalpable lesion localization using a curved-end retractable wire
    • Homer M J. Nonpalpable lesion localization using a curved-end retractable wire. Radiology 1985; 157: 259-260.
    • (1985) Radiology , vol.157 , pp. 259-260
    • Homer, M.J.1
  • 16
    • 0031031985 scopus 로고    scopus 로고
    • Impact of core biopsy on the surgical management of impalpable reast cancer
    • Liberman L, LaTrenta L R, Dershaw D et al. Impact of core biopsy on the surgical management of impalpable reast cancer. Am J Roentgenol 1997; 168: 495-499.
    • (1997) Am. J. Roentgenol. , vol.168 , pp. 495-499
    • Liberman, L.1    LaTrenta, L.R.2    Dershaw, D.3
  • 17
    • 0025322861 scopus 로고
    • The non-palpable, radiographically suspicious breast lesion: An analysis of 101 cases
    • Perre C I, Hoynck van Papendrecht A A, Sierink H D, Muller J W. The non-palpable, radiographically suspicious breast lesion: an analysis of 101 cases. Neth J Surg 1990; 42(3): 69-71.
    • (1990) Neth. J. Surg. , vol.42 , Issue.3 , pp. 69-71
    • Perre, C.I.1    Hoynck van Papendrecht, A.A.2    Sierink, H.D.3    Muller, J.W.4
  • 18
    • 0029850626 scopus 로고    scopus 로고
    • Impalpable breast lesions diagnosed by mammography: Incidence of histologically confirmed malignancy
    • Rothman L P, Harvald T B, Overgaard H. Impalpable breast lesions diagnosed by mammography: incidence of histologically confirmed malignancy. Eur J Surg 1996; 162(9): 691-694.
    • (1996) Eur. J. Surg. , vol.162 , Issue.9 , pp. 691-694
    • Rothman, L.P.1    Harvald, T.B.2    Overgaard, H.3
  • 19
    • 0032975568 scopus 로고    scopus 로고
    • The breast biopsy paradigm shifts once again
    • Silverstein M J, Silberman H. The breast biopsy paradigm shifts once again. Ann Surg Oncol 1999; 6(4): 323-324.
    • (1999) Ann. Surg. Oncol. , vol.6 , Issue.4 , pp. 323-324
    • Silverstein, M.J.1    Silberman, H.2
  • 20
    • 0033073949 scopus 로고    scopus 로고
    • Contribution of hook-guided breast biopsy to the pathological diagnosis of mammographic lesions
    • Jortay A M, Daled H, Faverly D. Contribution of hook-guided breast biopsy to the pathological diagnosis of mammographic lesions. Acta Chir Belg 1999; 99(1): 26-29.
    • (1999) Acta Chir. Belg. , vol.99 , Issue.1 , pp. 26-29
    • Jortay, A.M.1    Daled, H.2    Faverly, D.3
  • 21
    • 0023727938 scopus 로고
    • Technique and guidelines for needle localization biopsy of nonpalpable lesions of the breast
    • Wilhelm MC, Wanebo HJ. Technique and guidelines for needle localization biopsy of nonpalpable lesions of the breast. Surg Gynecol Obstet 1988; 167(5): 439-441
    • (1988) Surg. Gynecol. Obstet. , vol.167 , Issue.5 , pp. 439-441
    • Wilhelm, M.C.1    Wanebo, H.J.2
  • 22
    • 0031230623 scopus 로고    scopus 로고
    • Preoperative hook wire marking of nonpalpable suspected breast lesions
    • Sotje G, Waschkies R, Burba H et al. Preoperative hook wire marking of nonpalpable suspected breast lesions. Aktuel Radiol 1997; 7(5): 253-255.
    • (1997) Aktuel Radiol. , vol.7 , Issue.5 , pp. 253-255
    • Sotje, G.1    Waschkies, R.2    Burba, H.3
  • 23
    • 0030002702 scopus 로고    scopus 로고
    • Mammographically detected breast cancer. Benefits of stereotactic core versus wire localization biopsy
    • Yim J H, Barton P, Weber B et al. Mammographically detected breast cancer. Benefits of stereotactic core versus wire localization biopsy. Ann Surg 1996; 6: 688-700.
    • (1996) Ann. Surg. , vol.6 , pp. 688-700
    • Yim, J.H.1    Barton, P.2    Weber, B.3
  • 24
    • 0030730092 scopus 로고    scopus 로고
    • Image-guided core biopsy has advantages over localization biopsy for the diagnosis of non-palpable breast cancer
    • Whitten T M, Wallace T W, Bird R E, Turk P S. Image-guided core biopsy has advantages over localization biopsy for the diagnosis of non-palpable breast cancer. Am Surg 1997; 12: 1072-1077.
    • (1997) Am. Surg. , vol.12 , pp. 1072-1077
    • Whitten, T.M.1    Wallace, T.W.2    Bird, R.E.3    Turk, P.S.4
  • 25
    • 0026043250 scopus 로고
    • Breast biopsy techniques and adequacy of margins
    • Ngai J H, Zelles G W, Rumore G J et al. Breast biopsy techniques and adequacy of margins. Arch Surg 1991; 126; 1343-1347.
    • (1991) Arch. Surg. , vol.126 , pp. 1343-1347
    • Ngai, J.H.1    Zelles, G.W.2    Rumore, G.J.3
  • 26
    • 0030749032 scopus 로고    scopus 로고
    • Needle-localized breast biopsy: Why do we fail?
    • Jackman R J, Marzoni F A. Needle-localized breast biopsy: why do we fail? Radiology 1997; 204: 677-684.
    • (1997) Radiology , vol.204 , pp. 677-684
    • Jackman, R.J.1    Marzoni, F.A.2
  • 27
    • 0032976596 scopus 로고    scopus 로고
    • Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    • Jackman R J, Nowels K W, Rodriquez-Soto J, Marzoni F A Jr, Finkelstein S I, Shepard M J. Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 1999; 210: 799-805.
    • (1999) Radiology , vol.210 , pp. 799-805
    • Jackman, R.J.1    Nowels, K.W.2    Rodriquez-Soto, J.3    Marzoni F.A., Jr.4    Finkelstein, S.I.5    Shepard, M.J.6
  • 28
    • 0034937917 scopus 로고    scopus 로고
    • Sonographically guided directional vacuum-assisted breast biopsy using a handheld device
    • Parker S H, Klaus A J, McWey P J, Schilling K J, Cupples T E et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. Am J Roentgenol 2001; 177(2): 405-408.
    • (2001) Am. J. Roentgenol. , vol.177 , Issue.2 , pp. 405-408
    • Parker, S.H.1    Klaus, A.J.2    McWey, P.J.3    Schilling, K.J.4    Cupples, T.E.5
  • 29
    • 0034837994 scopus 로고    scopus 로고
    • Diagnostic accuracy of vacuum-assisted biopsy for image-detected breast lesions
    • Hung W K, Lam H S, Lau Y, Chan C M, Yip A W. Diagnostic accuracy of vacuum-assisted biopsy for image-detected breast lesions, Aust N Z J Surg 2001; 71(8): 457-460.
    • (2001) Aust. N. Z. J. Surg. , vol.71 , Issue.8 , pp. 457-460
    • Hung, W.K.1    Lam, H.S.2    Lau, Y.3    Chan, C.M.4    Yip, A.W.5
  • 30
    • 0036511204 scopus 로고    scopus 로고
    • Vacuum-assisted breast biopsy on digital sterotaxic table of nonpalpable lesions non-recognisable by ultrasonography
    • Apesteguia L, Mellado M, Saenz J, Cordero L, Reparaz B, De Migel C. Vacuum-assisted breast biopsy on digital sterotaxic table of nonpalpable lesions non-recognisable by ultrasonography. Eur Radiol 2002; 12(3): 638-645.
    • (2002) Eur. Radiol. , vol.12 , Issue.3 , pp. 638-645
    • Apesteguia, L.1    Mellado, M.2    Saenz, J.3    Cordero, L.4    Reparaz, B.5    De Migel, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.