메뉴 건너뛰기




Volumn 78, Issue 5, 2008, Pages 922-925

Clinical evaluation of bracket bonding using two different polymerization sources

Author keywords

Bond failure rate; Light emitting diode; Tungsten quartz halogen

Indexed keywords


EID: 50949097497     PISSN: 00033219     EISSN: 00033219     Source Type: Journal    
DOI: 10.2319/072807-351.1     Document Type: Article
Times cited : (18)

References (30)
  • 2
    • 0242273201 scopus 로고    scopus 로고
    • Evaluation of a new curing light on the shear bond strength of orthodontic brackets
    • Bishara SE, Ajlouni R, Oonsombat C. Evaluation of a new curing light on the shear bond strength of orthodontic brackets. Angle Orthod. 2003;73:431-435.
    • (2003) Angle Orthod , vol.73 , pp. 431-435
    • Bishara, S.E.1    Ajlouni, R.2    Oonsombat, C.3
  • 3
    • 85180997514 scopus 로고    scopus 로고
    • Meyer GR, Ernst CP, Willershausen B. Decrease in power output of new light-emitting diode (LED) curing devices with increasing distance to filling surface. J Adhes Dent. 2002;4:197-204.
    • Meyer GR, Ernst CP, Willershausen B. Decrease in power output of new light-emitting diode (LED) curing devices with increasing distance to filling surface. J Adhes Dent. 2002;4:197-204.
  • 4
    • 0034332577 scopus 로고    scopus 로고
    • Advances in light curing
    • Althoff O, Hartung M. Advances in light curing. Am J Dent. 2000;13(special issue):77D-81D.
    • (2000) Am J Dent , vol.13 , Issue.SPEC. ISSUE
    • Althoff, O.1    Hartung, M.2
  • 5
    • 0034013693 scopus 로고    scopus 로고
    • Light-emitting diode (LED) polymerization of dental composites: Flexural properties and polymerization potential
    • Stahl F, Ashworth SH, Jandt KD, Mills RW. Light-emitting diode (LED) polymerization of dental composites: flexural properties and polymerization potential. Biomaterials. 2000;21:1379-1385.
    • (2000) Biomaterials , vol.21 , pp. 1379-1385
    • Stahl, F.1    Ashworth, S.H.2    Jandt, K.D.3    Mills, R.W.4
  • 6
    • 0033599665 scopus 로고    scopus 로고
    • Dental composite depth of cure with halogen and blue light emitting diode technology
    • Mills RW, Jandt KD, Ashworth SH. Dental composite depth of cure with halogen and blue light emitting diode technology. Br Dent J. 1999;186:388-391.
    • (1999) Br Dent J , vol.186 , pp. 388-391
    • Mills, R.W.1    Jandt, K.D.2    Ashworth, S.H.3
  • 7
    • 0036719296 scopus 로고    scopus 로고
    • Polymerization of orthodontic resin cement with light-emitting diode curing units
    • Dunn WJ, Taloumis LJ. Polymerization of orthodontic resin cement with light-emitting diode curing units. Am J Orthod Dentofacial Orthop. 2002;122:236-241.
    • (2002) Am J Orthod Dentofacial Orthop , vol.122 , pp. 236-241
    • Dunn, W.J.1    Taloumis, L.J.2
  • 8
    • 1542297356 scopus 로고    scopus 로고
    • Shear bond strength of orthodontic brackets bonded with light-emitting diode curing units at various polymerisation times
    • Swanson T, Dunn WJ, Childers DE, Taloumis LJ. Shear bond strength of orthodontic brackets bonded with light-emitting diode curing units at various polymerisation times. Am J Orthod Dentofacial Orthop. 2004;125:337-341.
    • (2004) Am J Orthod Dentofacial Orthop , vol.125 , pp. 337-341
    • Swanson, T.1    Dunn, W.J.2    Childers, D.E.3    Taloumis, L.J.4
  • 9
    • 16644371685 scopus 로고    scopus 로고
    • A comparative in vitro study of the strength of directly bonded brackets using different curing techniques
    • Wendl B, Droschl H. A comparative in vitro study of the strength of directly bonded brackets using different curing techniques. Eur J Orthod. 2004;26:535-544.
    • (2004) Eur J Orthod , vol.26 , pp. 535-544
    • Wendl, B.1    Droschl, H.2
  • 10
    • 0028373851 scopus 로고
    • A critique of bond strength testing in orthodontics
    • Fox NA, McCabe JF, Buckley JG. A critique of bond strength testing in orthodontics. Br J Orthod. 1994;21:33-43.
    • (1994) Br J Orthod , vol.21 , pp. 33-43
    • Fox, N.A.1    McCabe, J.F.2    Buckley, J.G.3
  • 11
    • 0034132948 scopus 로고    scopus 로고
    • The inappropriateness of conventional orthodontic bond strength assessment protocols
    • Eliades T, Brantley WA. The inappropriateness of conventional orthodontic bond strength assessment protocols. Eur J Orthod. 2000;22:13-23.
    • (2000) Eur J Orthod , vol.22 , pp. 13-23
    • Eliades, T.1    Brantley, W.A.2
  • 12
    • 16644389022 scopus 로고    scopus 로고
    • The effects of argon laser curing of a resin adhesive on bracket retention and enamel decalcifi-cation: A prospective clinical trial
    • Elaut J, Wehrbein H. The effects of argon laser curing of a resin adhesive on bracket retention and enamel decalcifi-cation: a prospective clinical trial. Eur J Orthod. 2004;26:553-560.
    • (2004) Eur J Orthod , vol.26 , pp. 553-560
    • Elaut, J.1    Wehrbein, H.2
  • 13
    • 13844276250 scopus 로고    scopus 로고
    • An in vivo study to compare a plasma arc light and a conventional quartz halogen curing light in orthodontic bonding
    • Pettemerides AP, Sherriff M, Ireland AJ. An in vivo study to compare a plasma arc light and a conventional quartz halogen curing light in orthodontic bonding. Eur J Orthod. 2004;26:573-577.
    • (2004) Eur J Orthod , vol.26 , pp. 573-577
    • Pettemerides, A.P.1    Sherriff, M.2    Ireland, A.J.3
  • 14
    • 11244308938 scopus 로고    scopus 로고
    • Optical power outputs, spectra and dental composite depths of cure, obtained with blue light emitting diode (LED) and halogen light curing units (LCUs)
    • Mills RW, Uhl A, Jandt KD. Optical power outputs, spectra and dental composite depths of cure, obtained with blue light emitting diode (LED) and halogen light curing units (LCUs).Br Dent J. 2002;193:459-463.
    • (2002) Br Dent J , vol.193 , pp. 459-463
    • Mills, R.W.1    Uhl, A.2    Jandt, K.D.3
  • 15
    • 0018003873 scopus 로고
    • A post-treatment survey of direct bonding of metal brackets
    • Newman GV. A post-treatment survey of direct bonding of metal brackets. Am J Orthod. 1978;74:197-206.
    • (1978) Am J Orthod , vol.74 , pp. 197-206
    • Newman, G.V.1
  • 17
    • 0030294311 scopus 로고    scopus 로고
    • A clinical trial comparing the failure rates of two orthodontic bonding systems
    • Trimpeneers LM, Dermaut LR. A clinical trial comparing the failure rates of two orthodontic bonding systems. Am J Orthod Dentofacial Orthop. 1996;110:547-550.
    • (1996) Am J Orthod Dentofacial Orthop , vol.110 , pp. 547-550
    • Trimpeneers, L.M.1    Dermaut, L.R.2
  • 19
    • 0032199123 scopus 로고    scopus 로고
    • Clinical performance of orthodontic brackets and adhesive systems: A randomized clinical trial
    • Sunna S, Rock WP. Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial. Br J Orthod. 1998;25:283-287.
    • (1998) Br J Orthod , vol.25 , pp. 283-287
    • Sunna, S.1    Rock, W.P.2
  • 20
    • 0033208820 scopus 로고    scopus 로고
    • Comparison of bracket debonding force between two conventional resin adhesives and a resin-reinforced glass ionomer cement: An in vitro and in vivo study
    • Shammaa I, Ngan P, Kim H, Kao E, Gladwin M, Gunel E, Brown C. Comparison of bracket debonding force between two conventional resin adhesives and a resin-reinforced glass ionomer cement: an in vitro and in vivo study. Angle Orthod. 1999;69:463-469.
    • (1999) Angle Orthod , vol.69 , pp. 463-469
    • Shammaa, I.1    Ngan, P.2    Kim, H.3    Kao, E.4    Gladwin, M.5    Gunel, E.6    Brown, C.7
  • 22
    • 0034232153 scopus 로고    scopus 로고
    • Clinical comparison of the bond failure rates between fluoride-releasing and non-fluoride-releasing composite resins
    • Chung CH, Piatti A. Clinical comparison of the bond failure rates between fluoride-releasing and non-fluoride-releasing composite resins. J Clin Orthod. 2000;34:409-412.
    • (2000) J Clin Orthod , vol.34 , pp. 409-412
    • Chung, C.H.1    Piatti, A.2
  • 23
    • 4043052992 scopus 로고    scopus 로고
    • Plasma arc versus halogen light-curing of adhesive-precoated orthodontic brackets: A 12-month clinical study of bond failures
    • Cacciafesta V, Sfondrini MF, Scribante A. Plasma arc versus halogen light-curing of adhesive-precoated orthodontic brackets: a 12-month clinical study of bond failures. Am J Orthod Dentofacial Orthop. 2004;126:194-199.
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 194-199
    • Cacciafesta, V.1    Sfondrini, M.F.2    Scribante, A.3
  • 24
    • 0024225878 scopus 로고
    • A clinical trial comparing the failure rates of directly bonded brackets using etch times of 15 or 60 seconds
    • Kinch AP, Taylor H, Warltier R, Oliver RG, Newcombe RG. A clinical trial comparing the failure rates of directly bonded brackets using etch times of 15 or 60 seconds. Am J Orthod Dentofacial Orthop. 1988;94:476-483.
    • (1988) Am J Orthod Dentofacial Orthop , vol.94 , pp. 476-483
    • Kinch, A.P.1    Taylor, H.2    Warltier, R.3    Oliver, R.G.4    Newcombe, R.G.5
  • 25
    • 0020121738 scopus 로고
    • Success and failure of banding and bonding. A clinical study
    • Mizrahi E. Success and failure of banding and bonding. A clinical study. Angle Orthod. 1982;52:113-117.
    • (1982) Angle Orthod , vol.52 , pp. 113-117
    • Mizrahi, E.1
  • 27
    • 0036691616 scopus 로고    scopus 로고
    • Clinical bond failure of pre-coated and operator-coated orthodontic brackets
    • Kula K, Schreiner R, Brown J, Glaros A. Clinical bond failure of pre-coated and operator-coated orthodontic brackets. Orthod Craniofac Res. 2002;5:161-165.
    • (2002) Orthod Craniofac Res , vol.5 , pp. 161-165
    • Kula, K.1    Schreiner, R.2    Brown, J.3    Glaros, A.4
  • 28
    • 0015643412 scopus 로고
    • Correlation study of incisive biting forces with age, sex and anterior occlusion
    • Garner LD, Kotwal NS. Correlation study of incisive biting forces with age, sex and anterior occlusion. J Dent Res. 1973;52:698-702.
    • (1973) J Dent Res , vol.52 , pp. 698-702
    • Garner, L.D.1    Kotwal, N.S.2
  • 29
    • 0021520949 scopus 로고
    • Implications of the failure rates of bonded brackets and eyelets: A clinical study
    • Gorelick L, Geiger AM, Gwinnett AJ. Implications of the failure rates of bonded brackets and eyelets: a clinical study. Am J Orthod. 1984;86:403-406.
    • (1984) Am J Orthod , vol.86 , pp. 403-406
    • Gorelick, L.1    Geiger, A.M.2    Gwinnett, A.J.3
  • 30
    • 0019969941 scopus 로고
    • Structural variations in the surface zone of human tooth enamel observed by scanning electron microscopy
    • Whittaker DK. Structural variations in the surface zone of human tooth enamel observed by scanning electron microscopy. Arch Oral Biol. 1982;27:383-392.
    • (1982) Arch Oral Biol , vol.27 , pp. 383-392
    • Whittaker, D.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.