-
1
-
-
0027370108
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
-
Diabetes Control and Complications Trial Research Group
-
Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329 (1993) 977-986
-
(1993)
N Engl J Med
, vol.329
, pp. 977-986
-
-
-
2
-
-
0031870801
-
Factors associated with glycemic control: a cross-sectional nationwide study in 2,579 French children with type 1 diabetes
-
Rosilio M., Cotton J.B., and Wieliczko M.C. Factors associated with glycemic control: a cross-sectional nationwide study in 2,579 French children with type 1 diabetes. Diabetes Care 21 (1998) 1146-1153
-
(1998)
Diabetes Care
, vol.21
, pp. 1146-1153
-
-
Rosilio, M.1
Cotton, J.B.2
Wieliczko, M.C.3
-
3
-
-
15144346422
-
Insulin management and metabolic control of type 1 diabetes mellitus in childhood and adolescence in 18 countries
-
Mortensen H.B., Robertson K.J., and Aanstoot H.J. Insulin management and metabolic control of type 1 diabetes mellitus in childhood and adolescence in 18 countries. Diabet Med 15 (1998) 752-759
-
(1998)
Diabet Med
, vol.15
, pp. 752-759
-
-
Mortensen, H.B.1
Robertson, K.J.2
Aanstoot, H.J.3
-
4
-
-
0035656734
-
A pilot study of the Continuous Glucose Monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects
-
Kaufman F.R., Fisher L.K., Gibson L.C., Halvorson M., Carpenter S., and Pitukcheewanont P. A pilot study of the Continuous Glucose Monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects. Diabetes Care 24 (2001) 2030-2034
-
(2001)
Diabetes Care
, vol.24
, pp. 2030-2034
-
-
Kaufman, F.R.1
Fisher, L.K.2
Gibson, L.C.3
Halvorson, M.4
Carpenter, S.5
Pitukcheewanont, P.6
-
5
-
-
0036843560
-
Nocturnal hypoglycemia detected with continuous glucose monitoring system in pediatric type 1 patients
-
Kaufman F.R., Austin J., Neinstein A., Jeng L., Halvorson M., Devoe D., et al. Nocturnal hypoglycemia detected with continuous glucose monitoring system in pediatric type 1 patients. J Pediatr 141 (2002) 625-630
-
(2002)
J Pediatr
, vol.141
, pp. 625-630
-
-
Kaufman, F.R.1
Austin, J.2
Neinstein, A.3
Jeng, L.4
Halvorson, M.5
Devoe, D.6
-
6
-
-
6444227286
-
Assessment of glycemic control by continuous glucose monitoring system in 50 children with type 1 diabetes starting on insulin pump therapy
-
Deiss D., Hartmann R., Hoeffe J., and Kordonouri O. Assessment of glycemic control by continuous glucose monitoring system in 50 children with type 1 diabetes starting on insulin pump therapy. Pediatric Diabetes 5 (2004) 117-121
-
(2004)
Pediatric Diabetes
, vol.5
, pp. 117-121
-
-
Deiss, D.1
Hartmann, R.2
Hoeffe, J.3
Kordonouri, O.4
-
7
-
-
3142719318
-
The use of a continuous glucose monitoring system in hypoglycemic disorders
-
Conrad S.C., Mastrototaro J.J., and Gitelman S.E. The use of a continuous glucose monitoring system in hypoglycemic disorders. J Pediatr Endocrinol Metab 17 (2004) 281-288
-
(2004)
J Pediatr Endocrinol Metab
, vol.17
, pp. 281-288
-
-
Conrad, S.C.1
Mastrototaro, J.J.2
Gitelman, S.E.3
-
8
-
-
0037386040
-
Use of the Gluco Watch biographer in children with type 1 diabetes
-
Chase H.P., Roberts M.D., Wightman C., Klingensmith G., Garg S.K., Van Wyhe M., et al. Use of the Gluco Watch biographer in children with type 1 diabetes. Pediatrics 111 (2003) 790-794
-
(2003)
Pediatrics
, vol.111
, pp. 790-794
-
-
Chase, H.P.1
Roberts, M.D.2
Wightman, C.3
Klingensmith, G.4
Garg, S.K.5
Van Wyhe, M.6
-
9
-
-
0345862180
-
Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system
-
Schaepelynck-Belicar P., Vague P., Simonin G., and Lassmann-Vague V. Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system. Diabetes Metab 29 (2003) 608-612
-
(2003)
Diabetes Metab
, vol.29
, pp. 608-612
-
-
Schaepelynck-Belicar, P.1
Vague, P.2
Simonin, G.3
Lassmann-Vague, V.4
-
10
-
-
3042781935
-
Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous infusion
-
Weintrob N., Schechter A., Benzaquen H., Shalitin S., Lilos P., and Galatzer A. Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous infusion. Arch Pediatr Adolesc Med 158 (2004) 677-684
-
(2004)
Arch Pediatr Adolesc Med
, vol.158
, pp. 677-684
-
-
Weintrob, N.1
Schechter, A.2
Benzaquen, H.3
Shalitin, S.4
Lilos, P.5
Galatzer, A.6
-
11
-
-
0041666413
-
Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs
-
Guerci B., Floriot M., Bohme P., Durain D., Benichou M., Jellimann S., and Drouin P. Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs. Diabetes Care 26 (2003) 582-589
-
(2003)
Diabetes Care
, vol.26
, pp. 582-589
-
-
Guerci, B.1
Floriot, M.2
Bohme, P.3
Durain, D.4
Benichou, M.5
Jellimann, S.6
Drouin, P.7
|