Volumn , Issue , 2007, Pages 48-54
|
Electrical testing of low and medium voltage motors
a
a
Iris Power LP
(Canada)
|
Author keywords
Current signature; Growler; Induction motor testing; Insulation resistance; Partial discharge; Surge testing
|
Indexed keywords
ELECTRIC CURRENTS;
EXPOSURE CONTROLS;
INDUCTION MOTORS;
MAINTAINABILITY;
MAINTENANCE;
MOTORS;
PAPER COATING;
PAPER PRODUCTS;
PARTIAL DISCHARGES;
PULP;
STANDARDS;
TESTING;
TRANSFORMER WINDINGS;
WINDING;
CURRENT SIGNATURE;
ELECTRICAL TESTING;
GROWLER;
IEC STANDARDS;
INDUCTION MOTOR TESTING;
INSULATION RESISTANCE;
MEDIUM-VOLTAGE;
PARTIAL DISCHARGE;
PARTIAL DISCHARGE TESTING;
POLARIZATION INDEX;
PREDICTIVE MAINTENANCE;
PULP AND PAPER;
ROTOR WINDINGS;
SIGNATURE ANALYSIS;
SQUIRREL CAGE INDUCTION MOTOR;
STATOR WINDINGS;
SURGE TESTING;
TECHNICAL CONFERENCES;
TEST METHODS;
PAPER AND PULP INDUSTRY;
|
EID: 50149104755
PISSN: 01902172
EISSN: None
Source Type: Conference Proceeding
DOI: 10.1109/PAPCON.2007.4286283 Document Type: Conference Paper |
Times cited : (2)
|
References (13)
|