메뉴 건너뛰기




Volumn , Issue , 2005, Pages 95-101

Using current signature analysis technology to reliably detect cage winding defects in squirrel cage induction motors

Author keywords

[No Author keywords available]

Indexed keywords

FALSE ALARMS; HEALTHY MACHINES; ROTOR WINDINGS; SIGNATURE ANALYSIS;

EID: 28444478452     PISSN: 00903507     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PCICON.2005.1524544     Document Type: Conference Paper
Times cited : (11)

References (6)
  • 1
    • 0002876378 scopus 로고
    • Induction motor fault detection via passive current monitoring
    • MIT, Boston, USA
    • G B Kilman and J Stein: "Induction Motor Fault Detection Via Passive Current Monitoring", Proc Int. Conference (ICEM'90), MIT, Boston, USA, 1990, pp 13-17.
    • (1990) Proc Int. Conference (ICEM'90)
    • Kilman, G.B.1    Stein, J.2
  • 2
    • 0004566706 scopus 로고
    • Case histories of rotor winding fault diagnosis in induction motors
    • University College Swansea, March
    • W T Thomson and D Rankin: 'Case Histories of Rotor Winding Fault Diagnosis in Induction Motors", 2nd Int Conf Proc on Condition Monitoring, University College Swansea, March 1987.
    • (1987) 2nd Int Conf Proc on Condition Monitoring
    • Thomson, W.T.1    Rankin, D.2
  • 4
    • 28444455860 scopus 로고    scopus 로고
    • Squirrel cage rotor testing
    • San Francisco, CA, June
    • Tom Bishop, EASA Convention 2003, San Francisco, CA, June, 2003 "Squirrel Cage Rotor Testing".
    • (2003) EASA Convention 2003
    • Bishop, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.