-
1
-
-
0024464088
-
Electrode pad size, transthoracic impedance and success of external ventricular defibrillation
-
Dalzell GW, Cunningham SR, Anderson J, et al. Electrode pad size, transthoracic impedance and success of external ventricular defibrillation. Am J Cardiol 1989 64 : 741 744.
-
(1989)
Am J Cardiol
, vol.64
, pp. 741-744
-
-
Dalzell, G.W.1
Cunningham, S.R.2
Anderson, J.3
-
2
-
-
0019416196
-
Determinants of intracardiac current in defibrillation: Experimental studies in dogs
-
Hoyt R, Grayzel J, Kerber RE. Determinants of intracardiac current in defibrillation: experimental studies in dogs. Circulation 1981 64 : 818 823.
-
(1981)
Circulation
, vol.64
, pp. 818-823
-
-
Hoyt, R.1
Grayzel, J.2
Kerber, R.E.3
-
3
-
-
0024448644
-
A prospective randomized evaluation of BP versus MP waveform pulses on defibrillation efficacy in humans
-
Bardy GH, Ivey TD, Allen MD, et al. A prospective randomized evaluation of BP versus MP waveform pulses on defibrillation efficacy in humans. J Am Coll Cardiol 1989 14 : 728 733.
-
(1989)
J Am Coll Cardiol
, vol.14
, pp. 728-733
-
-
Bardy, G.H.1
Ivey, T.D.2
Allen, M.D.3
-
4
-
-
0028124651
-
A prospective randomized cross-over comparison of mono- and BP defibrillation using nonthoracotomy lead configurations in humans
-
Block MB, Hammel D, Bocker D, et al. A prospective randomized cross-over comparison of mono- and BP defibrillation using nonthoracotomy lead configurations in humans. J Cardiovasc Electrophysiol 1994 5 : 581 590.
-
(1994)
J Cardiovasc Electrophysiol
, vol.5
, pp. 581-590
-
-
Block, M.B.1
Hammel, D.2
Bocker, D.3
-
5
-
-
0029009182
-
BP waveform defibrillation investigators. Comparison of MP and BP defibrillating pulse waveforms for transthoracic cardioversion
-
Greene HL, DiMarco JP, Kudenchuk PJ, et al. BP waveform defibrillation investigators. Comparison of MP and BP defibrillating pulse waveforms for transthoracic cardioversion. Am J Cardiol 1995 75 : 1135 1139.
-
(1995)
Am J Cardiol
, vol.75
, pp. 1135-1139
-
-
Greene, H.L.1
Dimarco, J.P.2
Kudenchuk, P.J.3
-
6
-
-
0029083307
-
Transthoracic defibrillation of swine with MP and BP waveforms
-
Gliner BE, Lyster TE, Dillion SM, et al. Transthoracic defibrillation of swine with MP and BP waveforms. Circulation 1995 92 : 1634 1643.
-
(1995)
Circulation
, vol.92
, pp. 1634-1643
-
-
Gliner, B.E.1
Lyster, T.E.2
Dillion, S.M.3
-
7
-
-
0028293437
-
Overlapping sequential pulses: A new waveform for transthoracic defibrillation
-
Kerber RE, Spencer KT, Kallok MJ, et al. Overlapping sequential pulses: a new waveform for transthoracic defibrillation. Circulation 1994 89 : 2369 2379.
-
(1994)
Circulation
, vol.89
, pp. 2369-2379
-
-
Kerber, R.E.1
Spencer, K.T.2
Kallok, M.J.3
-
8
-
-
0028964064
-
Truncated BP pulses for transthoracic defibrillation
-
Bardy GH, Gliner BE, Kudenchuk PJ, et al. Truncated BP pulses for transthoracic defibrillation. Circulation 1995 91 : 1768 1774.
-
(1995)
Circulation
, vol.91
, pp. 1768-1774
-
-
Bardy, G.H.1
Gliner, B.E.2
Kudenchuk, P.J.3
-
9
-
-
0001398902
-
Multicenter comparison of truncated BP shocks and standard damped sine wave MP shocks for transthoracic ventricular defibrillation
-
Bardy GH, Marchlinski FE, Sharma AD, et al. Multicenter comparison of truncated BP shocks and standard damped sine wave MP shocks for transthoracic ventricular defibrillation. Circulation 1996 94 : 2507 2514.
-
(1996)
Circulation
, vol.94
, pp. 2507-2514
-
-
Bardy, G.H.1
Marchlinski, F.E.2
Sharma, A.D.3
-
10
-
-
0032881680
-
The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function
-
Tang W, Weil MH, Sun S, et al. The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function. J Am Coll Cardiol 1999 34 : 815 822.
-
(1999)
J Am Coll Cardiol
, vol.34
, pp. 815-822
-
-
Tang, W.1
Weil, M.H.2
Sun, S.3
-
11
-
-
0036024422
-
Transthoracic biphasic waveform defibrillation at very high and very low energies: A comparison with monophasic waveforms in an animal model of ventricular fibrillation
-
Clark CB, Zhang Y, Davies LR, et al. Transthoracic biphasic waveform defibrillation at very high and very low energies: a comparison with monophasic waveforms in an animal model of ventricular fibrillation. Resuscitation 2002 54 : 183 186.
-
(2002)
Resuscitation
, vol.54
, pp. 183-186
-
-
Clark, C.B.1
Zhang, Y.2
Davies, L.R.3
-
12
-
-
0030873266
-
Biphasic transthoracic defibrillation causes fewer ECG ST-segment changes after shock
-
Reddy RK, Gleva MJ, Gliner BE, et al. Biphasic transthoracic defibrillation causes fewer ECG ST-segment changes after shock. Ann Emerg Med 1997 30 : 127 134.
-
(1997)
Ann Emerg Med
, vol.30
, pp. 127-134
-
-
Reddy, R.K.1
Gleva, M.J.2
Gliner, B.E.3
-
13
-
-
0023096299
-
Resuscitation-induced myocardial necrosis. Catecholamines and defibrillation
-
Karch SB. Resuscitation-induced myocardial necrosis. Catecholamines and defibrillation. Am J Forensic Med Pathol 1987 8 : 3 8.
-
(1987)
Am J Forensic Med Pathol
, vol.8
, pp. 3-8
-
-
Karch, S.B.1
-
14
-
-
0034633848
-
Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200- to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims. Optimized response to cardiac arrest (ORCA) investigators
-
Schneider T, Martens PR, Paschen H, et al. Multicenter, randomized, controlled trial of 150-J biphasic shocks compared with 200- to 360-J monophasic shocks in the resuscitation of out-of-hospital cardiac arrest victims. Optimized response to cardiac arrest (ORCA) investigators. Circulation 2000 102 : 1780 1787.
-
(2000)
Circulation
, vol.102
, pp. 1780-1787
-
-
Schneider, T.1
Martens, P.R.2
Paschen, H.3
-
15
-
-
0033799829
-
Transthoracic monophasic and biphasic defibrillation in a swine model: A comparison of efficacy, ST segment changes, and postshock hemodynamics
-
Niemann JT, Burian D, Garner D, et al. Transthoracic monophasic and biphasic defibrillation in a swine model: a comparison of efficacy, ST segment changes, and postshock hemodynamics. Resuscitation 2000 47 : 51 58.
-
(2000)
Resuscitation
, vol.47
, pp. 51-58
-
-
Niemann, J.T.1
Burian, D.2
Garner, D.3
-
16
-
-
84995139691
-
The use of M-mode echocardiography in determining cardiac output in dogs with normal, low, and high output states: Comparison to thermodilution method
-
Atkins CE, Curtis MB, McGuirk SM, et al. The use of M-mode echocardiography in determining cardiac output in dogs with normal, low, and high output states: comparison to thermodilution method. Vet Radiol Ultrasound 1992 33 : 297 304.
-
(1992)
Vet Radiol Ultrasound
, vol.33
, pp. 297-304
-
-
Atkins, C.E.1
Curtis, M.B.2
McGuirk, S.M.3
-
17
-
-
33745492363
-
A retrospective evaluation of transthoracic BP electrical cardioversion for atrial fibrillation in dogs
-
Bright JM, Martin JM, Mama K. A retrospective evaluation of transthoracic BP electrical cardioversion for atrial fibrillation in dogs. J Vet Cardiol 2005 7 : 85 96.
-
(2005)
J Vet Cardiol
, vol.7
, pp. 85-96
-
-
Bright, J.M.1
Martin, J.M.2
Mama, K.3
-
18
-
-
0034720824
-
Resuscitation after prolonged ventricular fibrillation with use of MP and BP waveform pulses for external defibrillation
-
Leng CT, Paradis NA, Calkins H, et al. Resuscitation after prolonged ventricular fibrillation with use of MP and BP waveform pulses for external defibrillation. Circulation 2000 101 : 2968 2974.
-
(2000)
Circulation
, vol.101
, pp. 2968-2974
-
-
Leng, C.T.1
Paradis, N.A.2
Calkins, H.3
-
19
-
-
0036842172
-
Defibrillation threshold and cardiac responses using an external BP defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets
-
Killingsworth CR, Melnick SB, Chapman FW, et al. Defibrillation threshold and cardiac responses using an external BP defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets. Resuscitation 2002 55 : 177 185.
-
(2002)
Resuscitation
, vol.55
, pp. 177-185
-
-
Killingsworth, C.R.1
Melnick, S.B.2
Chapman, F.W.3
-
20
-
-
0000021227
-
Guidelines 2000 for cardiopulmonary resuscitation & emergency cardiac care
-
American Heart Association.
-
American Heart Association. Guidelines 2000 for cardiopulmonary resuscitation & emergency cardiac care. Circulation 2000 102 : I1 I384.
-
(2000)
Circulation
, vol.102
-
-
-
21
-
-
0037528777
-
Use of automated external defibrillators for children: An update. An advisory statement from the pediatric advanced life support task force, International Liaison Committee on Resuscitation
-
Samson R, Berg R, Bingham R. Use of automated external defibrillators for children: an update. An advisory statement from the pediatric advanced life support task force, International Liaison Committee on Resuscitation. Resuscitation 2003 57 : 237 243.
-
(2003)
Resuscitation
, vol.57
, pp. 237-243
-
-
Samson, R.1
Berg, R.2
Bingham, R.3
-
22
-
-
0028928372
-
Pediatric patients requiring CPR in the prehospital setting
-
Hickey RW, Cohen DM, Strausbaugh S, et al. Pediatric patients requiring CPR in the prehospital setting. Ann Emerg Med 1995 25 : 495 501.
-
(1995)
Ann Emerg Med
, vol.25
, pp. 495-501
-
-
Hickey, R.W.1
Cohen, D.M.2
Strausbaugh, S.3
-
23
-
-
0025314119
-
Increasing fibrillation duration enhances relative asymmetrical BP versus MP defibrillator waveform efficacy
-
Jones JL, Swartz JF, Jones RE, et al. Increasing fibrillation duration enhances relative asymmetrical BP versus MP defibrillator waveform efficacy. Circ Res 1990 67 : 376 384.
-
(1990)
Circ Res
, vol.67
, pp. 376-384
-
-
Jones, J.L.1
Swartz, J.F.2
Jones, R.E.3
-
24
-
-
0018764388
-
Factors influencing the success of ventricular defibrillation in man
-
Kerber RE, Sarnat W. Factors influencing the success of ventricular defibrillation in man. Circulation 1979 60 : 226 230.
-
(1979)
Circulation
, vol.60
, pp. 226-230
-
-
Kerber, R.E.1
Sarnat, W.2
-
25
-
-
0032921461
-
The influence of ventricular fibrillation duration on defibrillation efficacy using BP waveforms in humans
-
Windecker S, Ideker RE, Plumb VJ, et al. The influence of ventricular fibrillation duration on defibrillation efficacy using BP waveforms in humans. J Am Coll Cardiol 1999 33 : 33 38.
-
(1999)
J Am Coll Cardiol
, vol.33
, pp. 33-38
-
-
Windecker, S.1
Ideker, R.E.2
Plumb, V.J.3
-
26
-
-
0035185455
-
Pediatric transthoracic defibrillation: Biphasic versus monophasic waveforms in an experimental model
-
Clark CB, Zhang Y, Davies LR, et al. Pediatric transthoracic defibrillation: biphasic versus monophasic waveforms in an experimental model. Resuscitation 2001 51 : 159 163.
-
(2001)
Resuscitation
, vol.51
, pp. 159-163
-
-
Clark, C.B.1
Zhang, Y.2
Davies, L.R.3
-
27
-
-
0017033852
-
Energy dose for ventricular defibrillation of children
-
Gutgesell HP, Tacker WA, Geddes LA, et al. Energy dose for ventricular defibrillation of children. Pediatrics 1976 58 : 898 901.
-
(1976)
Pediatrics
, vol.58
, pp. 898-901
-
-
Gutgesell, H.P.1
Tacker, W.A.2
Geddes, L.A.3
|