-
1
-
-
0024431388
-
Towards a quantitative analysis of corneal endothelial cell morphology: A review of techniques and their application
-
Doughty MJ. Towards a quantitative analysis of corneal endothelial cell morphology: a review of techniques and their application. Optom Vis Sci 1989 66 : 626 642.
-
(1989)
Optom Vis Sci
, vol.66
, pp. 626-642
-
-
Doughty, M.J.1
-
2
-
-
0034113837
-
The resiliency of the corneal endothelium to refractive and intraocular surgery
-
Edelhauser HF. The resiliency of the corneal endothelium to refractive and intraocular surgery. Cornea 2000 19 : 263 273.
-
(2000)
Cornea
, vol.19
, pp. 263-273
-
-
Edelhauser, H.F.1
-
3
-
-
0842331154
-
Clinical responses of the corneal endothelium
-
Bourne WM, McLaren JW. Clinical responses of the corneal endothelium. Exp Eye Res 2004 78 : 561 572.
-
(2004)
Exp Eye Res
, vol.78
, pp. 561-572
-
-
Bourne, W.M.1
McLaren, J.W.2
-
4
-
-
0024270423
-
Bestimmung der präoperativen zentralen Endothelzelldichte von Spenderhornhäuten: Kritischer Vergleich zweier Methoden
-
Amon M, Grasl MM, Scheidel W, Schranz R, Skorpik Ch. Bestimmung der präoperativen zentralen Endothelzelldichte von Spenderhornhäuten: Kritischer Vergleich zweier Methoden. Spektrum Augenheilkd 1988 2 : 245 248.
-
(1988)
Spektrum Augenheilkd
, vol.2
, pp. 245-248
-
-
Amon, M.1
Grasl, M.M.2
Scheidel, W.3
Schranz, R.4
Skorpik, Ch.5
-
7
-
-
0029131584
-
Morphometric analysis of the corneal endothelium with three different specular microscopes
-
Landesz M, Kamps A, Slart R, Siertsema JV, Van Rij G. Morphometric analysis of the corneal endothelium with three different specular microscopes. Doc Ophthalmol 1995 90 : 15 28.
-
(1995)
Doc Ophthalmol
, vol.90
, pp. 15-28
-
-
Landesz, M.1
Kamps, A.2
Slart, R.3
Siertsema, J.V.4
Van Rij, G.5
-
8
-
-
0029991956
-
The Topcon SP 1000 and Image-NET systems. a comparison of four methods for evaluating corneal endothelial cell density
-
Vecchi M, Braccio L, Orsoni JG. The Topcon SP 1000 and Image-NET systems. A comparison of four methods for evaluating corneal endothelial cell density. Cornea 1996 15 : 271 277.
-
(1996)
Cornea
, vol.15
, pp. 271-277
-
-
Vecchi, M.1
Braccio, L.2
Orsoni, J.G.3
-
9
-
-
0029100336
-
Endotheliale Keratopathie bei Pseudoexfoliationssyndrome: Quantitative und qualitative Morphometrie mittels automisierter Videobildanalyse
-
Seitz B, Müller EE, Langenbucher A, Kus MM, Naumann GOH. Endotheliale Keratopathie bei Pseudoexfoliationssyndrome: Quantitative und qualitative Morphometrie mittels automisierter Videobildanalyse. Klin Monatsbl Augenheilkd 1995 207 : 167 175.
-
(1995)
Klin Monatsbl Augenheilkd
, vol.207
, pp. 167-175
-
-
Seitz, B.1
Müller, E.E.2
Langenbucher, A.3
Kus, M.M.4
Naumann, G.O.H.5
-
10
-
-
0030611330
-
Reproduzierbarkeit und Validität eines neuen automatisierten Verfahrens der spiegelmikroskopischen Hornhautendothelanalyse
-
Seitz B, Müller EE, Langenbucher A, Kus MM. Reproduzierbarkeit und Validität eines neuen automatisierten Verfahrens der spiegelmikroskopischen Hornhautendothelanalyse. Ophthalmologe 1997 94 : 127 135.
-
(1997)
Ophthalmologe
, vol.94
, pp. 127-135
-
-
Seitz, B.1
Müller, E.E.2
Langenbucher, A.3
Kus, M.M.4
-
11
-
-
85014952906
-
Endothelial cell analysis using the Topcon SP-1000 non-contact specular microscope and IMAGEnet system
-
Cheung S-W, Cho P. Endothelial cell analysis using the Topcon SP-1000 non-contact specular microscope and IMAGEnet system. Clin Exp Optom 1998 81 : 1 7.
-
(1998)
Clin Exp Optom
, vol.81
, pp. 1-7
-
-
Cheung, S.-W.1
Cho, P.2
-
12
-
-
0034493035
-
Endothelial cell analysis with the TOPCON specular microscope SP-2000P and IMAGEnet system
-
Cheung SW, Cho P. Endothelial cell analysis with the TOPCON specular microscope SP-2000P and IMAGEnet system. Curr Eye Res 2000 21 : 788 798.
-
(2000)
Curr Eye Res
, vol.21
, pp. 788-798
-
-
Cheung, S.W.1
Cho, P.2
-
13
-
-
0032899298
-
Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi systems
-
Benetz BAM, Diaconu E, Bowlin SJ, Oak SS, Laing RA, Lass JH. Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi systems. Cornea 1999 18 : 67 72.
-
(1999)
Cornea
, vol.18
, pp. 67-72
-
-
Benetz, B.A.M.1
Diaconu, E.2
Bowlin, S.J.3
Oak, S.S.4
Laing, R.A.5
Lass, J.H.6
-
14
-
-
0033016628
-
Comparison of recording systems and analysis methods in specular microscopy
-
Ohno K, Nelson LR, McLaren JW, Hodge DO, Bourne WM. Comparison of recording systems and analysis methods in specular microscopy. Cornea 1999 18 : 416 423.
-
(1999)
Cornea
, vol.18
, pp. 416-423
-
-
Ohno, K.1
Nelson, L.R.2
McLaren, J.W.3
Hodge, D.O.4
Bourne, W.M.5
-
15
-
-
0033952328
-
Comparison of endothelial cell density estimated by contact and non-contact specular microscopy
-
Isager P, Hjortdal JO, Guo S, Ehlers N. Comparison of endothelial cell density estimated by contact and non-contact specular microscopy. Acta Ophthalmol Scand 2000 78 : 42 44.
-
(2000)
Acta Ophthalmol Scand
, vol.78
, pp. 42-44
-
-
Isager, P.1
Hjortdal, J.O.2
Guo, S.3
Ehlers, N.4
-
16
-
-
0034954527
-
Reliability and reproducibility of corneal endothelial image analysis by in vivo confocal microscopy
-
Imre L, Nagymihaly A. Reliability and reproducibility of corneal endothelial image analysis by in vivo confocal microscopy. Graefe's Arch Clin Exp Ophthalmol 2001 239 : 356 360.
-
(2001)
Graefe's Arch Clin Exp Ophthalmol
, vol.239
, pp. 356-360
-
-
Imre, L.1
Nagymihaly, A.2
-
17
-
-
0035171846
-
Quantitative and morphological characteristics of human corneal endothelium in relation to age, gender and ethnicity in cataract populations of south Asia
-
Snellingen T, Gullapalli GN, Shrestha JK, Huq F, Cheng H. Quantitative and morphological characteristics of human corneal endothelium in relation to age, gender and ethnicity in cataract populations of south Asia. Cornea 2001 20 : 55 58.
-
(2001)
Cornea
, vol.20
, pp. 55-58
-
-
Snellingen, T.1
Gullapalli, G.N.2
Shrestha, J.K.3
Huq, F.4
Cheng, H.5
-
18
-
-
0035158075
-
Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium 3 years postoperatively
-
Collins MJ, Carr JD, Stulting RD, Azar R, Waring GO, Smith RE, Thompson KP, Edelhauser HF. Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium 3 years postoperatively. Am J Ophthalmol 2001 131 : 1 6.
-
(2001)
Am J Ophthalmol
, vol.131
, pp. 1-6
-
-
Collins, M.J.1
Carr, J.D.2
Stulting, R.D.3
Azar, R.4
Waring, G.O.5
Smith, R.E.6
Thompson, K.P.7
Edelhauser, H.F.8
-
19
-
-
0036798205
-
Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy
-
Módis L, Langenbucher A, Seitz B. Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy. J Cataract Refract Surg 2002 28 : 1763 1769.
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1763-1769
-
-
Módis, L.1
Langenbucher, A.2
Seitz, B.3
-
20
-
-
0037838876
-
Reliability of corneal thickness and endothelial cell density measures
-
Nichols JJ, Kosunick GM, Bullimore MA. Reliability of corneal thickness and endothelial cell density measures. J Refract Surg 2003 19 : 344 352.
-
(2003)
J Refract Surg
, vol.19
, pp. 344-352
-
-
Nichols, J.J.1
Kosunick, G.M.2
Bullimore, M.A.3
-
21
-
-
0041843611
-
Comparison of confocal biomicroscopy and non-contact specular microscopy for evaluation of the corneal endothelium
-
Hara M, Morishige N, Chikama T-I, Nishida T. Comparison of confocal biomicroscopy and non-contact specular microscopy for evaluation of the corneal endothelium. Cornea 2003 22 : 512 515.
-
(2003)
Cornea
, vol.22
, pp. 512-515
-
-
Hara, M.1
Morishige, N.2
Chikama, T.-I.3
Nishida, T.4
-
22
-
-
0037280735
-
Comparison of endothelial cell count using confocal and contact specular miscoscopy
-
Klais CMC, Bühren J, Kohnen T. Comparison of endothelial cell count using confocal and contact specular miscoscopy. Ophthalmologica 2003 217 : 99 103.
-
(2003)
Ophthalmologica
, vol.217
, pp. 99-103
-
-
Klais, C.M.C.1
Bühren, J.2
Kohnen, T.3
-
23
-
-
28044469557
-
Comparison of corneal endothelial cell images from a non-contact specular microscope and a scanning confocal microscope
-
Kitzmann AS, Winter EJ, Nau CB, Mclaren JW, Hodge DO, Bourne WM. Comparison of corneal endothelial cell images from a non-contact specular microscope and a scanning confocal microscope. Cornea 2005 24 : 980 984.
-
(2005)
Cornea
, vol.24
, pp. 980-984
-
-
Kitzmann, A.S.1
Winter, E.J.2
Nau, C.B.3
McLaren, J.W.4
Hodge, D.O.5
Bourne, W.M.6
-
24
-
-
21244450408
-
Validity of endothelial cell analysis methods and recommendations for calibration in Topcon SP-2000P specular microscopy
-
Van Schaick W, Van Dooren BTH, Mulder PGH, Völker-Dieben MJM. Validity of endothelial cell analysis methods and recommendations for calibration in Topcon SP-2000P specular microscopy. Cornea 2005 24 : 538 544.
-
(2005)
Cornea
, vol.24
, pp. 538-544
-
-
Van Schaick, W.1
Van Dooren, B.T.H.2
Mulder, P.G.H.3
Völker-Dieben, M.J.M.4
-
25
-
-
27244440150
-
Morphometry of cells and guttae in subjects with normal or gutte endothelium with a contour detection algorithm
-
Giasson CJ, Graham A, Blouin J-F, Solomon L, Gresset J, Melillo M, Polse KA. Morphometry of cells and guttae in subjects with normal or gutte endothelium with a contour detection algorithm. Eye Contact Lens 2005 31 : 158 165.
-
(2005)
Eye Contact Lens
, vol.31
, pp. 158-165
-
-
Giasson, C.J.1
Graham, A.2
Blouin, J.-F.3
Solomon, L.4
Gresset, J.5
Melillo, M.6
Polse, K.A.7
-
26
-
-
33746661774
-
Corneal endothelium evaluation with 2 noncontact specular miscroscopes and their semiautomated methods of analysis
-
De Sanctis U, Machetta F, Razzano L, Dalmasso P, Grignolo FM. Corneal endothelium evaluation with 2 noncontact specular miscroscopes and their semiautomated methods of analysis. Cornea 2006 25 : 501 506.
-
(2006)
Cornea
, vol.25
, pp. 501-506
-
-
De Sanctis, U.1
MacHetta, F.2
Razzano, L.3
Dalmasso, P.4
Grignolo, F.M.5
-
27
-
-
34548231383
-
Reliability of a video-based noncontact specular microscope for assessing the corneal endothelium
-
Prinz A, Varga J, Findl O. Reliability of a video-based noncontact specular microscope for assessing the corneal endothelium. Cornea 2007 26 : 924 929.
-
(2007)
Cornea
, vol.26
, pp. 924-929
-
-
Prinz, A.1
Varga, J.2
Findl, O.3
-
28
-
-
33845966398
-
Endothelial cell density in donor corneas. a comparison of automatic software programs with manual counting
-
Hirneiss C, Schumann RG, Gruterich M, Welge-Luessen UC, Kampik A, Neubauer AS. Endothelial cell density in donor corneas. A comparison of automatic software programs with manual counting. Cornea 2007 26 : 80 83.
-
(2007)
Cornea
, vol.26
, pp. 80-83
-
-
Hirneiss, C.1
Schumann, R.G.2
Gruterich, M.3
Welge-Luessen, U.C.4
Kampik, A.5
Neubauer, A.S.6
-
29
-
-
33846827204
-
Assessment of the human corneal endothelium: In vivo Topcon SP2000P specular microscope versus ex vivo sambacornea eye bank analyser
-
Thuret G, Deb-Joardar N, Manissolle C, Zhao M, Peoch M, Gain P, Gavet Y. Assessment of the human corneal endothelium: in vivo Topcon SP2000P specular microscope versus ex vivo sambacornea eye bank analyser. Br J Ophthalmol 2007 91 : 265 266.
-
(2007)
Br J Ophthalmol
, vol.91
, pp. 265-266
-
-
Thuret, G.1
Deb-Joardar, N.2
Manissolle, C.3
Zhao, M.4
Peoch, M.5
Gain, P.6
Gavet, Y.7
-
31
-
-
0020056043
-
Non-contact specular microscopy of the normal corneal endothelium. a statistical evaluation of morphometric parameters
-
Stefansson A, Muller O, Sundmacher R. Non-contact specular microscopy of the normal corneal endothelium. A statistical evaluation of morphometric parameters. Graefe's Arch Clin Exp Ophthalmol 1982 218 : 200 205.
-
(1982)
Graefe's Arch Clin Exp Ophthalmol
, vol.218
, pp. 200-205
-
-
Stefansson, A.1
Muller, O.2
Sundmacher, R.3
-
33
-
-
0027984835
-
Property and clinical availability of the noncontact autofocus specular microscope [in Japanese
-
Tagawa H, Kado M, Okada A, Furukawa H. Property and clinical availability of the noncontact autofocus specular microscope [in Japanese J Jpn Ophthalmol Soc 1994 98 : 772 776.
-
(1994)
J Jpn Ophthalmol Soc
, vol.98
, pp. 772-776
-
-
Tagawa, H.1
Kado, M.2
Okada, A.3
Furukawa, H.4
-
34
-
-
84908219488
-
Statistical measures for assessing agreement between two methods of clinical measures
-
Bland JM, Altman DG. Statistical measures for assessing agreement between two methods of clinical measures. Lancet 1986 1 : 307 310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
35
-
-
0027164559
-
Assessment of the reliability of calculations of coefficient of variation for normal and polymegethous human corneal endothelium
-
Doughty MJ, Fonn D, Nguyen KT. Assessment of the reliability of calculations of coefficient of variation for normal and polymegethous human corneal endothelium. Optom Vis Sci 1993 70 : 759 770.
-
(1993)
Optom Vis Sci
, vol.70
, pp. 759-770
-
-
Doughty, M.J.1
Fonn, D.2
Nguyen, K.T.3
-
36
-
-
38249016406
-
The ambiguous coefficient of variation: Polymegethism of the corneal endothelium and central corneal thickness
-
Doughty MJ. The ambiguous coefficient of variation: Polymegethism of the corneal endothelium and central corneal thickness. ICLC 1990 17 : 240 247.
-
(1990)
ICLC
, vol.17
, pp. 240-247
-
-
Doughty, M.J.1
-
37
-
-
0036699878
-
A semi-automated assessment of cell size and shape in monolayers, with optional adjustment for cell border width - Application to human corneal endothelium
-
Oblak E, Doughty MJ, Oblak L. A semi-automated assessment of cell size and shape in monolayers, with optional adjustment for cell border width - application to human corneal endothelium. Tissue Cell 2002 34 : 283 295.
-
(2002)
Tissue Cell
, vol.34
, pp. 283-295
-
-
Oblak, E.1
Doughty, M.J.2
Oblak, L.3
-
38
-
-
36649008336
-
Could the coefficient of variation (COV) of the corneal endothelium be overestimated when a centre-dot method is used?
-
Doughty MJ. Could the coefficient of variation (COV) of the corneal endothelium be overestimated when a centre-dot method is used? Clin Exp Optom 2008 91 : 103 110.
-
(2008)
Clin Exp Optom
, vol.91
, pp. 103-110
-
-
Doughty, M.J.1
-
39
-
-
0031658565
-
Prevalence of 'non-hexagonal' cells in the corneal endothelium of young Caucasian adults, and their inter-relationships
-
Doughty MJ. Prevalence of 'non-hexagonal' cells in the corneal endothelium of young Caucasian adults, and their inter-relationships. Ophthalmic Physiol Opt 1998 18 : 415 422.
-
(1998)
Ophthalmic Physiol Opt
, vol.18
, pp. 415-422
-
-
Doughty, M.J.1
-
40
-
-
0036298873
-
Automated tri-image analysis of stored corneal endothelium
-
Gain P, Thuret G, Kodjikian L, Gavet Y, Turc PH, Theillere C, Acquart S, Le Petit JC, Maugery J, Campos L. Automated tri-image analysis of stored corneal endothelium. Br J Ophthalmol 2002 86 : 801 808.
-
(2002)
Br J Ophthalmol
, vol.86
, pp. 801-808
-
-
Gain, P.1
Thuret, G.2
Kodjikian, L.3
Gavet, Y.4
Turc, P.H.5
Theillere, C.6
Acquart, S.7
Le Petit, J.C.8
Maugery, J.9
Campos, L.10
-
41
-
-
34547092149
-
Central versus paracentral endothelial cell density values in relation to duration of soft contact lens wear
-
Doughty MJ, Aakre BM. Central versus paracentral endothelial cell density values in relation to duration of soft contact lens wear. Eye Contact Lens 2007 33 : 180 184.
-
(2007)
Eye Contact Lens
, vol.33
, pp. 180-184
-
-
Doughty, M.J.1
Aakre, B.M.2
|