Validity of endothelial cell analysis methods and recommendations for calibration in topcon SP-2000P specular microscopy

Author keywords

Calibration; Endothelial cell density; Specular microscopy; Validity of assessment methods

Indexed keywords

ADULT; AGED; ARTICLE; CALIBRATION; CELL DENSITY; CLINICAL ARTICLE; COMPUTER PROGRAM; ENDOTHELIUM CELL; HUMAN; IMAGING SYSTEM; INTERMETHOD COMPARISON; MATHEMATICAL ANALYSIS; MEASUREMENT; MEDICAL INSTRUMENTATION; METHODOLOGY; PRIORITY JOURNAL; SPECULAR MICROSCOPY;

EID: 21244450408     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ico.0000151505.03824.6c     Document Type: Article
Times cited : (66)

References (14)
  • 1
    • 0029991956 scopus 로고    scopus 로고
    • The Topcon SP 1000 and Image-NET systems. A comparison of four methods for evaluating corneal endothelial cell density
    • Vecchi M, Braccio L, Orsoni JG. The Topcon SP 1000 and Image-NET systems. A comparison of four methods for evaluating corneal endothelial cell density. Cornea. 1996;15:271-277.
    • (1996) Cornea , vol.15 , pp. 271-277
    • Vecchi, M.1    Braccio, L.2    Orsoni, J.G.3
  • 2
    • 0033016628 scopus 로고    scopus 로고
    • Comparison of recording systems and analysis methods in specular microscopy
    • Ohno K, Nelson LR, McLaren JW, et al. Comparison of recording systems and analysis methods in specular microscopy. Cornea. 1999;18:416-423.
    • (1999) Cornea , vol.18 , pp. 416-423
    • Ohno, K.1    Nelson, L.R.2    McLaren, J.W.3
  • 3
    • 0032899298 scopus 로고    scopus 로고
    • Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi Systems
    • Benetz BA, Diaconu E, Bowlin SJ, et al. Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi Systems. Cornea. 1999;18:67-72.
    • (1999) Cornea , vol.18 , pp. 67-72
    • Benetz, B.A.1    Diaconu, E.2    Bowlin, S.J.3
  • 4
    • 0018825978 scopus 로고
    • Four methods of measuring human corneal endothelial cells from specular photomicrographs
    • Waring GO 3rd, Krohn MA, Ford GE, et al. Four methods of measuring human corneal endothelial cells from specular photomicrographs. Arch Ophthalmol 1980;98:848-855.
    • (1980) Arch Ophthalmol , vol.98 , pp. 848-855
    • Waring III, G.O.1    Krohn, M.A.2    Ford, G.E.3
  • 5
    • 0024431388 scopus 로고
    • Toward a quantitative analysis of corneal endothelial cell morphology: A review of techniques and their application
    • Doughty MJ. Toward a quantitative analysis of corneal endothelial cell morphology: a review of techniques and their application. Optom Vis Sci. 1989;66:626-642.
    • (1989) Optom Vis Sci , vol.66 , pp. 626-642
    • Doughty, M.J.1
  • 6
    • 84981459110 scopus 로고
    • Notes on the estimation of the numerical density of arbitrary profiles: The edge effect
    • Gundersen HJG. Notes on the estimation of the numerical density of arbitrary profiles: the edge effect. J Microsc. 1977;111:219-223.
    • (1977) J Microsc , vol.111 , pp. 219-223
    • Gundersen, H.J.G.1
  • 7
    • 0017842354 scopus 로고
    • The precision of unbiased estimates of numerical density of endothelial cells in donor corneas
    • Sperling S, Gundersen HJG. The precision of unbiased estimates of numerical density of endothelial cells in donor corneas. Acta Ophthalmol. 1978;56:793-802.
    • (1978) Acta Ophthalmol , vol.56 , pp. 793-802
    • Sperling, S.1    Gundersen, H.J.G.2
  • 8
    • 0002363710 scopus 로고
    • A note on normal correlation
    • Pitman E. A note on normal correlation. Biometrika. 1939;31:9-12.
    • (1939) Biometrika , vol.31 , pp. 9-12
    • Pitman, E.1
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;307-310.
    • (1986) Lancet , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0036798205 scopus 로고    scopus 로고
    • Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy
    • Modis L, Langenbucher A, Seitz B. Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy. J Cataract Refract Surg. 2002;28:1763-1769.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1763-1769
    • Modis, L.1    Langenbucher, A.2    Seitz, B.3
  • 11
    • 0342680092 scopus 로고    scopus 로고
    • Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope
    • Doughty MJ, Müller A, Zaman ML. Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope. Cornea. 2000;19:148-158.
    • (2000) Cornea , vol.19 , pp. 148-158
    • Doughty, M.J.1    Müller, A.2    Zaman, M.L.3
  • 12
    • 0029131584 scopus 로고
    • Morphometric analysis of the corneal endothelium with three different specular microscopes
    • Landesz M, Kamps A, Slart R, et al. Morphometric analysis of the corneal endothelium with three different specular microscopes. Doc Ophthalmol. 1995;90:15-28.
    • (1995) Doc Ophthalmol , vol.90 , pp. 15-28
    • Landesz, M.1    Kamps, A.2    Slart, R.3
  • 13
    • 0029115286 scopus 로고
    • Comparative study of three semiautomated specular microscopes
    • Landesz M, Siertsema JV, Van Rij G. Comparative study of three semiautomated specular microscopes. J Cataract Refract Surg. 1995;21:409-416.
    • (1995) J Cataract Refract Surg , vol.21 , pp. 409-416
    • Landesz, M.1    Siertsema, J.V.2    Van Rij, G.3
  • 14
    • 0030611330 scopus 로고    scopus 로고
    • Reproducibility and validity of a new automatic method of specular microscopy analysis of corneal endothelium
    • Seitz B, Muller EE, Langenbucher A, et al. O. Reproducibility and validity of a new automatic method of specular microscopy analysis of corneal endothelium. Ophthalmologe. 1997;94:127-135.
    • (1997) Ophthalmologe , vol.94 , pp. 127-135
    • Seitz, B.1    Muller, E.E.2    Langenbucher, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.