메뉴 건너뛰기




Volumn 7, Issue 4, 2008, Pages 582-585

Intraoperative graft flow measurements during coronary artery bypass surgery predict in-hospital outcomes

Author keywords

Cardiac surgery; Coronary artery disease; Outcomes

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD FLOWMETER; BLOOD FLOWMETRY; CALCULATION; CONFIDENCE INTERVAL; CORONARY ARTERY BYPASS SURGERY; FEMALE; FOLLOW UP; GRAFT PERFUSION; HOSPITAL ADMISSION; HOSPITAL DISCHARGE; HUMAN; INTRAOPERATIVE PERIOD; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; MORTALITY; OUTCOME ASSESSMENT; PARAMETER; PREDICTION; PRIORITY JOURNAL; PULSATILITY INDEX; RISK ASSESSMENT; TRANSIT TIME FLOWMETRY; TREATMENT OUTCOME;

EID: 49249138728     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2008.175208     Document Type: Article
Times cited : (30)

References (15)
  • 2
    • 0020556133 scopus 로고
    • Long-term fate of the internal mammary artery and saphenous vein grafts
    • Singh RN, Sosa JA, Green GE. Long-term fate of the internal mammary artery and saphenous vein grafts. J Thorac Cardiovasc Surg 1983;86:359-363.
    • (1983) J Thorac Cardiovasc Surg , vol.86 , pp. 359-363
    • Singh, R.N.1    Sosa, J.A.2    Green, G.E.3
  • 4
    • 0030245599 scopus 로고    scopus 로고
    • Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years
    • FitzGibbon GM, Leach AJ, Kafka HP, Keon WJ. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 1996;28:616-626.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 616-626
    • FitzGibbon, G.M.1    Leach, A.J.2    Kafka, H.P.3    Keon, W.J.4
  • 5
    • 0034773860 scopus 로고    scopus 로고
    • Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting
    • Takami Y, Ina H. Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting. Ann Thorac Surg 2001;72:1270-1274.
    • (2001) Ann Thorac Surg , vol.72 , pp. 1270-1274
    • Takami, Y.1    Ina, H.2
  • 6
    • 0033829208 scopus 로고    scopus 로고
    • Graft patency verification in coronary artery bypass grafting: Principles and clinincal applications of transit time flow measurement
    • D'Ancona G, Karamanoukian H, Ricci M, Bergsland J, Salerno T. Graft patency verification in coronary artery bypass grafting: principles and clinincal applications of transit time flow measurement. Angiology 2001;51:725-731.
    • (2001) Angiology , vol.51 , pp. 725-731
    • D'Ancona, G.1    Karamanoukian, H.2    Ricci, M.3    Bergsland, J.4    Salerno, T.5
  • 7
    • 22544487178 scopus 로고    scopus 로고
    • Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts
    • Kim K, Hyun Kang C, Lim C. Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts. Ann Thorac Surg 2005;80:594-598.
    • (2005) Ann Thorac Surg , vol.80 , pp. 594-598
    • Kim, K.1    Hyun Kang, C.2    Lim, C.3
  • 8
    • 0029878464 scopus 로고    scopus 로고
    • Managed delay for coronary artery bypass graft surgery: The experience at one Canadian center
    • Cox JL, Petrie JF, Pollak PT, Johnstone DE. Managed delay for coronary artery bypass graft surgery: the experience at one Canadian center. J Am Coll Cardiol 1996;27:1365-1373.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1365-1373
    • Cox, J.L.1    Petrie, J.F.2    Pollak, P.T.3    Johnstone, D.E.4
  • 9
    • 1342288499 scopus 로고    scopus 로고
    • Coronary bypass surgery performed off pump does not result in lower in-hospital morbidity than coronary artery bypass grafting performed on pump
    • Legare JF, Buth KJ, King S, Wood J, Sullivan JA, Hancock Friesen C, Lee J, Stewart K, Hirsch GM. Coronary bypass surgery performed off pump does not result in lower in-hospital morbidity than coronary artery bypass grafting performed on pump. Circulation 2004;109:887-892.
    • (2004) Circulation , vol.109 , pp. 887-892
    • Legare, J.F.1    Buth, K.J.2    King, S.3    Wood, J.4    Sullivan, J.A.5    Hancock Friesen, C.6    Lee, J.7    Stewart, K.8    Hirsch, G.M.9
  • 13
    • 0033302474 scopus 로고
    • Noninvasive graft flow and patency assessment following minimally invasive direct coronary artery bypass (MIDCAB) grafting
    • Chun HJ, Doty JR, Salazar JD, Richmond J, Fonger JD. Noninvasive graft flow and patency assessment following minimally invasive direct coronary artery bypass (MIDCAB) grafting. Heart Surg Forum 1992;2:230-234.
    • (1992) Heart Surg Forum , vol.2 , pp. 230-234
    • Chun, H.J.1    Doty, J.R.2    Salazar, J.D.3    Richmond, J.4    Fonger, J.D.5
  • 14
    • 34347368867 scopus 로고    scopus 로고
    • The impact of intraoperative transit time flow measurement on the result of on-pump coronary surgery
    • Becit N, Erkut B, Ceviz M, Unlu Y, Colak A, Kocak H. The impact of intraoperative transit time flow measurement on the result of on-pump coronary surgery. Eur J Cardiothorac Surg 2007;32:313-318.
    • (2007) Eur J Cardiothorac Surg , vol.32 , pp. 313-318
    • Becit, N.1    Erkut, B.2    Ceviz, M.3    Unlu, Y.4    Colak, A.5    Kocak, H.6
  • 15
    • 36248941369 scopus 로고    scopus 로고
    • Predicting early coronary artery bypass graft failure by intraoperative transit time flow measurement
    • Tokuda Y, Song MH, Ueda Y, Usui A, Akita T. Predicting early coronary artery bypass graft failure by intraoperative transit time flow measurement. Ann Thorac Surg 2007;84:1928-1933.
    • (2007) Ann Thorac Surg , vol.84 , pp. 1928-1933
    • Tokuda, Y.1    Song, M.H.2    Ueda, Y.3    Usui, A.4    Akita, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.