메뉴 건너뛰기




Volumn 32, Issue 2, 2007, Pages 313-318

The impact of intraoperative transit time flow measurement on the results of on-pump coronary surgery

Author keywords

CABG; Graft dysfunction; Transit time flow measurement

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL FEATURE; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; FEMALE; HEART INFARCTION; HUMAN; INTRAOPERATIVE PERIOD; MAJOR CLINICAL STUDY; MALE; MORTALITY; PRIORITY JOURNAL; PUMP DESIGN;

EID: 34347368867     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2007.04.037     Document Type: Article
Times cited : (50)

References (19)
  • 1
    • 23844436218 scopus 로고    scopus 로고
    • Intraoperative bypass flow measurement reduces the incidence of postoperative ventricular fibrillation and myocardial markers after coronary revascularisation
    • Bauer S.F., Bauer K., Ennker I.C., Rosendahl U., and Ennker J. Intraoperative bypass flow measurement reduces the incidence of postoperative ventricular fibrillation and myocardial markers after coronary revascularisation. Thorac Cardiovasc Surg 53 (2005) 217-222
    • (2005) Thorac Cardiovasc Surg , vol.53 , pp. 217-222
    • Bauer, S.F.1    Bauer, K.2    Ennker, I.C.3    Rosendahl, U.4    Ennker, J.5
  • 2
    • 0037217346 scopus 로고    scopus 로고
    • Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping in off-pump coronary artery surgery
    • Sanisoglu I., Guden M., Balci C., Sagbas E., Duran C., and Akpinar B. Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping in off-pump coronary artery surgery. Tex Heart Inst J 30 (2003) 31-37
    • (2003) Tex Heart Inst J , vol.30 , pp. 31-37
    • Sanisoglu, I.1    Guden, M.2    Balci, C.3    Sagbas, E.4    Duran, C.5    Akpinar, B.6
  • 4
    • 0037360278 scopus 로고    scopus 로고
    • Graft patency in off-pump and conventional coronary artery bypass grafting for treatment of triple vessel coronary disease
    • Hu S., Wang X., Song Y., and Lu F. Graft patency in off-pump and conventional coronary artery bypass grafting for treatment of triple vessel coronary disease. Chin Med J (Engl) 116 (2003) 436-439
    • (2003) Chin Med J (Engl) , vol.116 , pp. 436-439
    • Hu, S.1    Wang, X.2    Song, Y.3    Lu, F.4
  • 5
    • 22844432864 scopus 로고    scopus 로고
    • Evaluation of the coronary artery bypass graft
    • Akiyama K. Evaluation of the coronary artery bypass graft. Ann Thorac Cardiovasc Surg 11 (2005) 65-66
    • (2005) Ann Thorac Cardiovasc Surg , vol.11 , pp. 65-66
    • Akiyama, K.1
  • 6
    • 14244269536 scopus 로고    scopus 로고
    • Transit-time flow measurement is essential in coronary artery bypass grafting
    • Leong D.K., Ashok V., Nishkantha A., Shan Y.H., and Sim E.K. Transit-time flow measurement is essential in coronary artery bypass grafting. Ann Thorac Surg 79 (2005) 854-857
    • (2005) Ann Thorac Surg , vol.79 , pp. 854-857
    • Leong, D.K.1    Ashok, V.2    Nishkantha, A.3    Shan, Y.H.4    Sim, E.K.5
  • 7
    • 33747765271 scopus 로고    scopus 로고
    • Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery
    • Di Giammarco G., Pano M., Cirmeni S., Pelini P., Vitolla G., and Di Mauro M. Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. J Thorac Cardiovasc Surg 132 (2006) 468-474
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 468-474
    • Di Giammarco, G.1    Pano, M.2    Cirmeni, S.3    Pelini, P.4    Vitolla, G.5    Di Mauro, M.6
  • 9
    • 0034987937 scopus 로고    scopus 로고
    • An evaluation of the intraoperative transit time measurements of coronary bypass flow
    • Hirotani T., Kameda T., Shirota S., and Nakao Y. An evaluation of the intraoperative transit time measurements of coronary bypass flow. Eur J Cardio-thorac Surg 19 (2001) 848-852
    • (2001) Eur J Cardio-thorac Surg , vol.19 , pp. 848-852
    • Hirotani, T.1    Kameda, T.2    Shirota, S.3    Nakao, Y.4
  • 10
    • 18744362720 scopus 로고    scopus 로고
    • Baseline flow in coronary bypass grafts
    • Kjaergard H.K. Baseline flow in coronary bypass grafts. J Card Surg 20 (2005) 205-207
    • (2005) J Card Surg , vol.20 , pp. 205-207
    • Kjaergard, H.K.1
  • 11
    • 33646900196 scopus 로고    scopus 로고
    • Cardiomed coronary flow meters for prevention of early occlusion in aortocoronary bypass grafting
    • Gwozdziewicz M. Cardiomed coronary flow meters for prevention of early occlusion in aortocoronary bypass grafting. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 148 (2004) 59-61
    • (2004) Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub , vol.148 , pp. 59-61
    • Gwozdziewicz, M.1
  • 12
    • 0034755242 scopus 로고    scopus 로고
    • Is intraoperative measurement of coronary blood flow a good predictor of graft patency?
    • D'Ancona G., Karamanoukian H.L., and Bergsland J. Is intraoperative measurement of coronary blood flow a good predictor of graft patency?. Eur J Cardio-thorac Surg 20 (2001) 1075-1076
    • (2001) Eur J Cardio-thorac Surg , vol.20 , pp. 1075-1076
    • D'Ancona, G.1    Karamanoukian, H.L.2    Bergsland, J.3
  • 15
    • 22544487178 scopus 로고    scopus 로고
    • Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts
    • Kim K.B., Kang C.H., and Lim C. Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts. Ann Thorac Surg 80 (2005) 594-598
    • (2005) Ann Thorac Surg , vol.80 , pp. 594-598
    • Kim, K.B.1    Kang, C.H.2    Lim, C.3
  • 18
    • 0032864573 scopus 로고    scopus 로고
    • Severe impairment of graft flow without electrocardiographic changes during coronary artery bypass grafting
    • Jakobsen H.L., and Kjaergard H.K. Severe impairment of graft flow without electrocardiographic changes during coronary artery bypass grafting. Scand Cardiovasc J 33 (1999) 157-159
    • (1999) Scand Cardiovasc J , vol.33 , pp. 157-159
    • Jakobsen, H.L.1    Kjaergard, H.K.2
  • 19
    • 33746068287 scopus 로고    scopus 로고
    • Sequential bypass grafting on the beating heart: blood flow characteristics
    • Gwozdziewicz M., Nemec P., Simek M., Hajek R., and Troubil M. Sequential bypass grafting on the beating heart: blood flow characteristics. Ann Thorac Surg 82 (2006) 620-623
    • (2006) Ann Thorac Surg , vol.82 , pp. 620-623
    • Gwozdziewicz, M.1    Nemec, P.2    Simek, M.3    Hajek, R.4    Troubil, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.