Volumn 5, Issue 3, 2008, Pages 403-410

Improving the separation efficiency of DNA biosamples in capillary electrophoresis microchips using high-voltage pulsed DC electric fields

Author keywords

Capillary electrophoresis chip; Pulsed electric field; Separation efficiency

Indexed keywords

ATMOSPHERIC ELECTRICITY; CAPILLARY ELECTROPHORESIS; DNA; DYES; ELECTRIC FIELD EFFECTS; ELECTRIC FIELD MEASUREMENT; ELECTRIC FIELDS; ELECTROCHEMISTRY; ELECTROMAGNETIC FIELD THEORY; ELECTROMAGNETIC FIELDS; ELECTROMAGNETISM; ELECTROPHORESIS; GENES; INTEGRATED CIRCUITS; MAGNETISM; NUCLEIC ACIDS; ORGANIC ACIDS; SEPARATION; VOLTAGE REGULATORS;

EID: 49049088539     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-008-0259-7     Document Type: Article
Times cited : (31)

References (37)
  • 1
    • 33750375182 scopus 로고    scopus 로고
    • AC electroosmotic flow in a DNA concentrator
    • Bown MR, Meinhart CD (2006) AC electroosmotic flow in a DNA concentrator. Microfluid Nanofluid 2:513-523
    • (2006) Microfluid Nanofluid , vol.2 , pp. 513-523
    • Bown, M.R.1    Meinhart, C.D.2
  • 2
    • 0024400166 scopus 로고
    • Pulsed field electrophoresis in contour-clamped homogeneous electric-fields for the resolution of DNA by size or topology
    • Chu G (1989) Pulsed field electrophoresis in contour-clamped homogeneous electric-fields for the resolution of DNA by size or topology. Electrophoresis 10:290-295
    • (1989) Electrophoresis , vol.10 , pp. 290-295
    • Chu, G.1
  • 3
    • 0142216265 scopus 로고    scopus 로고
    • Development of a chip-integrated micro cooling device
    • Darabi J, Ekula K (2003) Development of a chip-integrated micro cooling device. Microelectron J 34:1067-1074
    • (2003) Microelectron J , vol.34 , pp. 1067-1074
    • Darabi, J.1    Ekula, K.2
  • 4
    • 33746230290 scopus 로고    scopus 로고
    • Modeling of coupled momentum, heat and solute transport during DNA hybridization in a microchannel in the presence of electro-osmotic effects and axial pressure gradients
    • Das S, Das T, Chakraborty S (2006) Modeling of coupled momentum, heat and solute transport during DNA hybridization in a microchannel in the presence of electro-osmotic effects and axial pressure gradients. Microfluid Nanofluid 2:37-49
    • (2006) Microfluid Nanofluid , vol.2 , pp. 37-49
    • Das, S.1    Das, T.2    Chakraborty, S.3
  • 5
    • 0242322757 scopus 로고    scopus 로고
    • Numerical analysis and experimental estimation of a low-leakage injection technique for capillary electrophoresis
    • Fu LM, Lin CH (2003) Numerical analysis and experimental estimation of a low-leakage injection technique for capillary electrophoresis. Anal Chem 75:5790-5796
    • (2003) Anal Chem , vol.75 , pp. 5790-5796
    • Fu, L.M.1    Lin, C.H.2
  • 6
    • 0346374842 scopus 로고    scopus 로고
    • Low-voltage driven control in electrophoresis microchips by traveling electric field
    • Fu LM, Yang RJ (2003) Low-voltage driven control in electrophoresis microchips by traveling electric field. Electrophoresis 24:1253-1260
    • (2003) Electrophoresis , vol.24 , pp. 1253-1260
    • Fu, L.M.1    Yang, R.J.2
  • 7
    • 27644544470 scopus 로고    scopus 로고
    • Capacitively-induced pulsed-field gel electrophoresis: A novel method for DNA separation
    • Ghourchian H, Elyasvandi H (2005) Capacitively-induced pulsed-field gel electrophoresis: A novel method for DNA separation. Med Eng Phys 27:723-727
    • (2005) Med Eng Phys , vol.27 , pp. 723-727
    • Ghourchian, H.1    Elyasvandi, H.2
  • 8
    • 33646879135 scopus 로고    scopus 로고
    • The flow resistance of single DNA-grafted colloids as measured by optical tweezers
    • Gutsche C, Salomo M, Kim YW, Netz RR, Kremer F (2006) The flow resistance of single DNA-grafted colloids as measured by optical tweezers. Microfluid Nanofluid 2:381-386
    • (2006) Microfluid Nanofluid , vol.2 , pp. 381-386
    • Gutsche, C.1    Salomo, M.2    Kim, Y.W.3    Netz, R.R.4    Kremer, F.5
  • 9
    • 0026425524 scopus 로고
    • Capillary gel affinity electrophoresis of DNA fragments
    • Guttman A, Cooke N (1991) Capillary gel affinity electrophoresis of DNA fragments. Anal Chem 63:2038-2042
    • (1991) Anal Chem , vol.63 , pp. 2038-2042
    • Guttman, A.1    Cooke, N.2
  • 10
    • 11944262834 scopus 로고
    • Capillary electrophoresis and sample injection systems integrated on a planar glass chip
    • Harrison DJ, Manz A, Fan ZH, Ludi H, Widmer HM (1992) Capillary electrophoresis and sample injection systems integrated on a planar glass chip. Anal Chem 64:1926-1932
    • (1992) Anal Chem , vol.64 , pp. 1926-1932
    • Harrison, D.J.1    Manz, A.2    Fan, Z.H.3    Ludi, H.4    Widmer, H.M.5
  • 11
    • 0014159493 scopus 로고
    • Free zone electrophoresis
    • Hjerten S (1967) Free zone electrophoresis. J Chromatogr Rev 9:122-219
    • (1967) J Chromatogr Rev , vol.9 , pp. 122-219
    • Hjerten, S.1
  • 12
    • 0141653940 scopus 로고    scopus 로고
    • Integrated nanoliter systems
    • Hong JW, Quake SR (2003) Integrated nanoliter systems. Nat Biotechnol 21:1179-1183
    • (2003) Nat Biotechnol , vol.21 , pp. 1179-1183
    • Hong, J.W.1    Quake, S.R.2
  • 13
    • 33744965919 scopus 로고    scopus 로고
    • Numerical modeling of the Joule heating effect on electrokinetic flow focusing
    • Huang KD, Yang RJ (2006) Numerical modeling of the Joule heating effect on electrokinetic flow focusing. Electrophoresis 27:1957-1966
    • (2006) Electrophoresis , vol.27 , pp. 1957-1966
    • Huang, K.D.1    Yang, R.J.2
  • 14
    • 0000159693 scopus 로고
    • Analysis of factors causing peak Broadening in Capillary Zone Electrophoresis
    • Huang XH, Coleman WF, Zare RN (1989) Analysis of factors causing peak Broadening in Capillary Zone Electrophoresis. J Chromatogr 480:95-110
    • (1989) J Chromatogr , vol.480 , pp. 95-110
    • Huang, X.H.1    Coleman, W.F.2    Zare, R.N.3
  • 15
    • 0035505906 scopus 로고    scopus 로고
    • A fast prototyping process for fabrication of microfluidic systems on soda-lime glass
    • Lin CH, Lee GB, Lin YH, Chang GL (2001) A fast prototyping process for fabrication of microfluidic systems on soda-lime glass. J Micromech Microeng 11:726-732
    • (2001) J Micromech Microeng , vol.11 , pp. 726-732
    • Lin, C.H.1    Lee, G.B.2    Lin, Y.H.3    Chang, G.L.4
  • 16
    • 34548319708 scopus 로고    scopus 로고
    • A plastic microchip for nucleic acid purification
    • Liu Y, Cady NC, Batt CA (2007) A plastic microchip for nucleic acid purification. Biomed Microdevices 9:769-776
    • (2007) Biomed Microdevices , vol.9 , pp. 769-776
    • Liu, Y.1    Cady, N.C.2    Batt, C.A.3
  • 17
    • 34147186318 scopus 로고    scopus 로고
    • Surface modification of poly (methyl methacrylate) microfluidic devices for high-resolution separations of single-stranded DNA
    • Llopis SL, Osiri J, Soper SA (2007) Surface modification of poly (methyl methacrylate) microfluidic devices for high-resolution separations of single-stranded DNA. Electrophoresis 28:984-993
    • (2007) Electrophoresis , vol.28 , pp. 984-993
    • Llopis, S.L.1    Osiri, J.2    Soper, S.A.3
  • 18
    • 34548301688 scopus 로고    scopus 로고
    • A simple device using magnetic transportation for droplet-based PCR
    • Ohashi T, Kuyama H, Hanafusa N, Togawa Y (2007) A simple device using magnetic transportation for droplet-based PCR. Biomed Microdevices 9:695-702
    • (2007) Biomed Microdevices , vol.9 , pp. 695-702
    • Ohashi, T.1    Kuyama, H.2    Hanafusa, N.3    Togawa, Y.4
  • 19
    • 0347764796 scopus 로고    scopus 로고
    • Peak dispersion and contributions to plate height in nonaqueous capillary electrophoresis at high electric field strengths: Propanol as background electrolyte solvent
    • Palonen S, Porras SP, Jussila M, Riekkola ML (2003) Peak dispersion and contributions to plate height in nonaqueous capillary electrophoresis at high electric field strengths: Propanol as background electrolyte solvent. Electrophoresis 24:1565-1576
    • (2003) Electrophoresis , vol.24 , pp. 1565-1576
    • Palonen, S.1    Porras, S.P.2    Jussila, M.3    Riekkola, M.L.4
  • 20
    • 1242296926 scopus 로고    scopus 로고
    • Peak dispersion and contributions to plate height in nonaqueous capillary electrophoresis at high electric field strengths: Ethanol as background electrolyte solvent
    • Palonen S, Jussila M, Porras SP, Riekkola ML (2004) Peak dispersion and contributions to plate height in nonaqueous capillary electrophoresis at high electric field strengths: Ethanol as background electrolyte solvent. Electrophoresis 25:344-354
    • (2004) Electrophoresis , vol.25 , pp. 344-354
    • Palonen, S.1    Jussila, M.2    Porras, S.P.3    Riekkola, M.L.4
  • 21
    • 0001549347 scopus 로고    scopus 로고
    • Numerical simulation of electroosmotic flow
    • Patankar NA, Hu HH (1998) Numerical simulation of electroosmotic flow. Anal Chem 70:1870-1881
    • (1998) Anal Chem , vol.70 , pp. 1870-1881
    • Patankar, N.A.1    Hu, H.H.2
  • 22
    • 33847140162 scopus 로고    scopus 로고
    • An integrated genetic analysis microfluidic platform with valves and a PCR chip reusability method to avoid contamination
    • Prakash R, Kaler KVIS (2007) An integrated genetic analysis microfluidic platform with valves and a PCR chip reusability method to avoid contamination. Microfluid Nanofluid 3:177-187
    • (2007) Microfluid Nanofluid , vol.3 , pp. 177-187
    • Prakash, R.1    Kaler, K.V.I.S.2
  • 24
    • 0026425295 scopus 로고
    • Influence of column temperature on the electrophoretic behavior of myoglobin and alpha-lactalbumin in high-performance capillary electrophoresis
    • Rush RS, Cohen AS, Karger BL (1991) Influence of column temperature on the electrophoretic behavior of myoglobin and alpha-lactalbumin in high-performance capillary electrophoresis. Anal Chem 63:1346-1350
    • (1991) Anal Chem , vol.63 , pp. 1346-1350
    • Rush, R.S.1    Cohen, A.S.2    Karger, B.L.3
  • 26
    • 34247581958 scopus 로고    scopus 로고
    • Modeling and experimental characterization of peak tailing in DNA gel electrophoresis
    • Sun Y, Kwok YC, Nguyen NT (2007) Modeling and experimental characterization of peak tailing in DNA gel electrophoresis. Microfluid Nanofluid 3:323-332
    • (2007) Microfluid Nanofluid , vol.3 , pp. 323-332
    • Sun, Y.1    Kwok, Y.C.2    Nguyen, N.T.3
  • 27
    • 33845996153 scopus 로고    scopus 로고
    • Genotyping with microfluidic devices
    • Szantai E, Guttman A (2006) Genotyping with microfluidic devices. Electrophoresis 27:4896-4903
    • (2006) Electrophoresis , vol.27 , pp. 4896-4903
    • Szantai, E.1    Guttman, A.2
  • 31
    • 0141765891 scopus 로고    scopus 로고
    • The "right" size in nanobiotechnology
    • Whitesides GM (2003) The "right" size in nanobiotechnology. Nat Biotechnol 21:1161-1165
    • (2003) Nat Biotechnol , vol.21 , pp. 1161-1165
    • Whitesides, G.M.1
  • 32
    • 4243169229 scopus 로고    scopus 로고
    • Joule heating effects on peak broadening in capillary zone electrophoresis
    • Xuan XC, Li DQ (2004) Joule heating effects on peak broadening in capillary zone electrophoresis. J Micromech Microeng 14:1171-1180
    • (2004) J Micromech Microeng , vol.14 , pp. 1171-1180
    • Xuan, X.C.1    Li, D.Q.2
  • 33
    • 12344324796 scopus 로고    scopus 로고
    • Analytical study of Joule heating effects on electrokinetic transportation in capillary electrophoresis
    • Xuan XC, Li DQ (2005a) Analytical study of Joule heating effects on electrokinetic transportation in capillary electrophoresis. J Chromatogr A 1064:227-237
    • (2005) J Chromatogr A , vol.1064 , pp. 227-237
    • Xuan, X.C.1    Li, D.Q.2
  • 34
    • 12344302767 scopus 로고    scopus 로고
    • Band-broadening in capillary zone electrophoresis with axial temperature gradients
    • Xuan XC, Li DQ (2005b) Band-broadening in capillary zone electrophoresis with axial temperature gradients. Electrophoresis 26:166-175
    • (2005) Electrophoresis , vol.26 , pp. 166-175
    • Xuan, X.C.1    Li, D.Q.2
  • 35
    • 2442585481 scopus 로고    scopus 로고
    • Thermal end effects on electroosmotic flow in a capillary
    • Xuan XC, Sinton D, Li DQ (2004a) Thermal end effects on electroosmotic flow in a capillary. Int J Heat Mass Tran 47:3145-3157
    • (2004) Int J Heat Mass Tran , vol.47 , pp. 3145-3157
    • Xuan, X.C.1    Sinton, D.2    Li, D.Q.3
  • 36
    • 3142706463 scopus 로고    scopus 로고
    • Electroosmotic flow with Joule heating effects
    • Xuan XC, Xu B, Sinton D, Li DQ (2004b) Electroosmotic flow with Joule heating effects. Lab Chip 4:230-236
    • (2004) Lab Chip , vol.4 , pp. 230-236
    • Xuan, X.C.1    Xu, B.2    Sinton, D.3    Li, D.Q.4
  • 37
    • 14944344957 scopus 로고    scopus 로고
    • Numerical simulation of electrokinetic injection techniques in capillary electrophoresis microchips
    • Tsai CH, Yang RJ, Tai CH, Fu LM (2005) Numerical simulation of electrokinetic injection techniques in capillary electrophoresis microchips. Electrophoresis 26:674-686
    • (2005) Electrophoresis , vol.26 , pp. 674-686
    • Tsai, C.H.1    Yang, R.J.2    Tai, C.H.3    Fu, L.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.