메뉴 건너뛰기




Volumn 38, Issue 6, 1997, Pages 1029-1034

k-Space detection and correction of physiological artifacts in fMRI

Author keywords

fMRI; Motion artifacts; Phase correction; Physiological correction

Indexed keywords

FMRI; MOTION ARTIFACT; PHASE CORRECTIONS; PHASE VARIATION; PHYSIOLOGICAL NOISE; PULSE SEQUENCE; RETROSPECTIVE METHOD; SOURCE OF INSTABILITY;

EID: 0030701614     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910380625     Document Type: Article
Times cited : (69)

References (21)
  • 2
    • 0026916948 scopus 로고
    • Dynamic MR imaging of human brain oxygenation during rest and photic stimulation
    • J. Frahm, H. Bruhn, K. D. Merboldt, W. Hanicke, Dynamic MR imaging of human brain oxygenation during rest and photic stimulation. J. Magn. Reson. Imaging 2, 501-505 (1992).
    • (1992) J. Magn. Reson. Imaging , vol.2 , pp. 501-505
    • Frahm, J.1    Bruhn, H.2    Merboldt, K.D.3    Hanicke, W.4
  • 7
    • 0027288454 scopus 로고
    • Processing strategies for time-course data sets in functional MRI of the human brain
    • P. A. Bandettini, A. Jesmanowicz, E. C. Wong, J. S. Hyde, Processing strategies for time-course data sets in functional MRI of the human brain. Magn. Reson. Med. 30, 161-173 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 161-173
    • Bandettini, P.A.1    Jesmanowicz, A.2    Wong, E.C.3    Hyde, J.S.4
  • 8
    • 0030053163 scopus 로고    scopus 로고
    • Reduction of physiological fluctuations in fMRI using digital filters
    • B. Biswal, E. A. DeYoe, I. S. Hyde, Reduction of physiological fluctuations in fMRI using digital filters. Magn. Reson. Med. 35, 107-113 (1996).
    • (1996) Magn. Reson. Med. , vol.35 , pp. 107-113
    • Biswal, B.1    DeYoe, E.A.2    Hyde, I.S.3
  • 10
    • 0000922561 scopus 로고    scopus 로고
    • Respiration artifacts in functional brain imaging: Sources of signal variation and compensation strategies
    • D. C. Noll, W. Schneider, Respiration artifacts in functional brain imaging: sources of signal variation and compensation strategies, in "Proc., SMR. 2nd Annual Meeting, San Francisco, 1994," p. 647.
    • Proc., SMR. 2nd Annual Meeting, San Francisco, 1994 , pp. 647
    • Noll, D.C.1    Schneider, W.2
  • 11
    • 0028285121 scopus 로고
    • Reduction of physiological noise in functional MRI using navigator echo
    • X. Hu, S.-G. Kim, Reduction of physiological noise in functional MRI using navigator echo. Magn. Reson. Med. 31, 495-503 (1984).
    • (1984) Magn. Reson. Med. , vol.31 , pp. 495-503
    • Hu, X.1    Kim, S.-G.2
  • 14
    • 0028920255 scopus 로고
    • Motion artifacts in fMRI: Comparison of 2DFT with PR and spiral scan methods
    • G. H. Glover, A. T. Lee, Motion artifacts in fMRI: comparison of 2DFT with PR and spiral scan methods. Magn. Reson. Med. 33, 624-635 (1995).
    • (1995) Magn. Reson. Med. , vol.33 , pp. 624-635
    • Glover, G.H.1    Lee, A.T.2
  • 15
    • 0029118783 scopus 로고
    • Retrospective estimation and correction of physiological fluctuation in functional MRI
    • X. Hu, T. H. Le, T. Parish, P. Erhard, Retrospective estimation and correction of physiological fluctuation in functional MRI. Magn. Reson. Med. 34, 201-212 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parish, T.3    Erhard, P.4
  • 16
    • 0008913870 scopus 로고    scopus 로고
    • Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data
    • T. H. Le, X. Hu, Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data. Magn. Reson. Med. 35, 290-298 (1996).
    • (1996) Magn. Reson. Med. , vol.35 , pp. 290-298
    • Le, T.H.1    Hu, X.2
  • 17
    • 0029094301 scopus 로고
    • Functional MRI of human brain activation combining high spatial and temporal resolution by a CINE FLASH technique
    • K. D. Merboldt, G. Kruger, W. Hanicke, A. Kleinschmidt, J. Frahm, Functional MRI of human brain activation combining high spatial and temporal resolution by a CINE FLASH technique. Magn. Reson. Med. 34, 639-644 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 639-644
    • Merboldt, K.D.1    Kruger, G.2    Hanicke, W.3    Kleinschmidt, A.4    Frahm, J.5
  • 18
    • 0029155699 scopus 로고
    • Correction of motional artifacts in diffusion-weighted images using a reference phase map
    • A. M. Ulug, P. B. Barker, P. C. M. van Zijl, Correction of motional artifacts in diffusion-weighted images using a reference phase map. Magn. Reson. Med. 34, 476-480 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 476-480
    • Ulug, A.M.1    Barker, P.B.2    Van Zijl, P.C.M.3
  • 19
    • 85036685524 scopus 로고    scopus 로고
    • K. U 151 urbil, a novel multislice FLASH sequence for functional magnetic resonance imaging
    • R. S. Menon, H. Merkle, K. U 151 urbil, A novel multislice FLASH sequence for functional magnetic resonance imaging, in "Proc., SMRM, 12th Annual Meeting, New York, 1993," p. 1203.
    • Proc., SMRM, 12th Annual Meeting, New York, 1993 , pp. 1203
    • Menon, R.S.1    Merkle, H.2
  • 20
    • 0027494434 scopus 로고
    • A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
    • G. Liu, G. Sobering, J. Duyn, C. T. Moonen, A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn. Heson. Med. 30, 764-768 (1993).
    • (1993) Magn. Heson. Med. , vol.30 , pp. 764-768
    • Liu, G.1    Sobering, G.2    Duyn, J.3    Moonen, C.T.4
  • 21
    • 0029954472 scopus 로고    scopus 로고
    • Multislice interleaved excitation cycles (MUSIC): An efficient gradient-echo technique for functional MRI
    • T. Loenneker, F. Hennel, J. Hennig, Multislice interleaved excitation cycles (MUSIC): an efficient gradient-echo technique for functional MRI. Magn. Reson. Med. 35, 870-874 (1996).
    • (1996) Magn. Reson. Med. , vol.35 , pp. 870-874
    • Loenneker, T.1    Hennel, F.2    Hennig, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.