메뉴 건너뛰기




Volumn 14, Issue 4, 1999, Pages 509-513

The effect of acetabular cup orientations on limiting hip rotation

Author keywords

Acetabular cup; Augmented cup; Cup position; Cup version; Range of motion; Rotation

Indexed keywords

ACETABULOPLASTY; ARTICLE; HIP DISLOCATION; JOINT MOBILITY; JOINT STABILITY; NONHUMAN; TOTAL HIP PROSTHESIS;

EID: 0032801048     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(99)90110-9     Document Type: Article
Times cited : (164)

References (11)
  • 1
    • 0017859205 scopus 로고
    • Incidence of dislocation following hip arthroplasty for patients in the rehabilitation setting
    • Lewinnek GE, Lewis JL, Tarr R, et al: Incidence of dislocation following hip arthroplasty for patients in the rehabilitation setting. J Bone Joint Surg Am 60:217, 1978
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 217
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 2
    • 0026522003 scopus 로고
    • Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty
    • Mian SW, Truchly G, Pflum FA: Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty. Clin Orthop Rel Res 276:206, 1992
    • (1992) Clin Orthop Rel Res , vol.276 , pp. 206
    • Mian, S.W.1    Truchly, G.2    Pflum, F.A.3
  • 4
    • 0020074590 scopus 로고
    • Prosthetic range of motion and impingement: The effects of head and neck geometry
    • Chandler DR, Glousman R, Hull D, et al: Prosthetic range of motion and impingement: the effects of head and neck geometry. Clin Orthop Rel Res 166:284, 1982
    • (1982) Clin Orthop Rel Res , vol.166 , pp. 284
    • Chandler, D.R.1    Glousman, R.2    Hull, D.3
  • 5
  • 6
    • 0025912479 scopus 로고
    • Range of motion in contemporary total hip arthroplasty
    • Krushell RJ, Burke DW, Harris WH: Range of motion in contemporary total hip arthroplasty. J Arthroplasty 6:97, 1991
    • (1991) J Arthroplasty , vol.6 , pp. 97
    • Krushell, R.J.1    Burke, D.W.2    Harris, W.H.3
  • 7
    • 0025282813 scopus 로고
    • Dislocation of total hip replacements: A comparative study of standard, long posterior wall and augmented acetabular components
    • Nicholas RM, Orr JF, Mollan RAB, et al: Dislocation of total hip replacements: a comparative study of standard, long posterior wall and augmented acetabular components. J Bone Joint Surg Br 72:418, 1990
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 418
    • Nicholas, R.M.1    Orr, J.F.2    Mollan, R.A.B.3
  • 8
    • 0023929635 scopus 로고
    • Total hip acetabular component position affects component loosening rates
    • Yoder SA, Brand R, Pedersen D, O'Gorman T: Total hip acetabular component position affects component loosening rates. Clin Orthop 228:79, 1988
    • (1988) Clin Orthop , vol.228 , pp. 79
    • Yoder, S.A.1    Brand, R.2    Pedersen, D.3    O'Gorman, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.