메뉴 건너뛰기




Volumn 6142 II, Issue , 2006, Pages

Investigation of emission contamination in the transmission image of a dual modality computed mammotomography system

Author keywords

CT; Dual modality; Emission contamination; Flat panel detector; Mammotomography; SPECT

Indexed keywords

DUAL MODALITY; EMISSION CONTAMINATION; FLAT PANEL DETECTORS; MAMMOTOMOGRAPHY; SPECT;

EID: 33745377441     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.654580     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 0142174116 scopus 로고    scopus 로고
    • Feasibility of Application Specific Emission and Transmission Tomography (ASETT) of the breast
    • M.P. Tornai, J.E. Bowsher, C.N. Archer, R.J. Jaszczak. "Feasibility of Application Specific Emission and Transmission Tomography (ASETT) of the Breast." J. Nucl. Med. 42 (5), 12P (2002).
    • (2002) J. Nucl. Med. , vol.42 , Issue.5
    • Tornai, M.P.1    Bowsher, J.E.2    Archer, C.N.3    Jaszczak, R.J.4
  • 2
    • 1942514306 scopus 로고    scopus 로고
    • Initial X-ray design considerations for Application Specific Emission and Transmission Tomography (ASETT) of the breast
    • M.L. Bradshaw, R.L. McKinley, E. Samei, C.N. Archer, M.P. Tornai. "Initial X-ray Design Considerations for Application Specific Emission and Transmission Tomography (ASETT) of the Breast." J. Nucl. Med., 44 (5), 287P (2003).
    • (2003) J. Nucl. Med. , vol.44 , Issue.5
    • Bradshaw, M.L.1    McKinley, R.L.2    Samei, E.3    Archer, C.N.4    Tornai, M.P.5
  • 3
    • 2942711891 scopus 로고    scopus 로고
    • Development of an optimal x-ray beam for dual-mode emission and transmission mammotomography
    • R.L. McKinley, M.P. Tornai, E. Samei, M.L. Bradshaw. "Development of an Optimal X-ray Beam for Dual-Mode Emission and Transmission Mammotomography." Nucl. Instr. Meth. Phys. Res., A527 (1), 102-109 (2004).
    • (2004) Nucl. Instr. Meth. Phys. Res. , vol.A527 , Issue.1 , pp. 102-109
    • McKinley, R.L.1    Tornai, M.P.2    Samei, E.3    Bradshaw, M.L.4
  • 4
    • 33745397543 scopus 로고    scopus 로고
    • Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method
    • W.H. Wong. H. Li. J. Uribe. H. Baghaei. Y. Wang, S. Yokoyama. "Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method." J. Nucl. Med, 44 (5), 24-32 (2001).
    • (2001) J. Nucl. Med , vol.44 , Issue.5 , pp. 24-32
    • Wong, W.H.1    Li, H.2    Uribe, J.3    Baghaei, H.4    Wang, Y.5    Yokoyama, S.6
  • 5
    • 0030859658 scopus 로고    scopus 로고
    • A novel method of scatter correction using a single isotope for simultaneous emission and transmission data
    • J. Yang, J.T. Kuikka, K. Jaatinen, E. Lansimies, L. Patomaki. "A novel method of scatter correction using a single isotope for simultaneous emission and transmission data." Nucl. Med. Comms., 18(11), 1071-6 (1997).
    • (1997) Nucl. Med. Comms. , vol.18 , Issue.11 , pp. 1071-1076
    • Yang, J.1    Kuikka, J.T.2    Jaatinen, K.3    Lansimies, E.4    Patomaki, L.5
  • 6
    • 33745354184 scopus 로고    scopus 로고
    • Optimizing orientation of SPECT and cone beam CT Detectors through quantification of cross contamination in a dual modality mammotomography system
    • D.J. Crotty, C.N. Brzymialkiewicz, R.L. McKinley, M.P. Toraai. "Optimizing Orientation of SPECT and Cone Beam CT Detectors Through Quantification of Cross Contamination in a Dual Modality Mammotomography System." IEEE Conf. Rec. Nucl. Sci. Symp. & Med. Imag. Conf. 1672-1676 (2005).
    • (2005) IEEE Conf. Rec. Nucl. Sci. Symp. & Med. Imag. Conf. , pp. 1672-1676
    • Crotty, D.J.1    Brzymialkiewicz, C.N.2    McKinley, R.L.3    Toraai, M.P.4
  • 9
    • 23744501752 scopus 로고    scopus 로고
    • Evaluation of fully 3D emission mammotomography with a compact cadmium zinc telluride detector
    • C.N. Brzymialkiewicz, M.P. Tornai, R.L. McKinley, J.E. Bowsher. "Evaluation of Fully 3D Emission Mammotomography with a Compact Cadmium Zinc Telluride Detector." IEEE Trans. Med. Imag. MI-24(7):868-877 (2005).
    • (2005) IEEE Trans. Med. Imag. , vol.MI-24 , Issue.7 , pp. 868-877
    • Brzymialkiewicz, C.N.1    Tornai, M.P.2    McKinley, R.L.3    Bowsher, J.E.4
  • 10
    • 23844455030 scopus 로고    scopus 로고
    • Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability
    • R.L. McKinley, C.N. Brzymialkiewicz, P. Madhav, M.P. Tornai. "Investigation of Cone-Beam Acquisitions Implemented Using a Novel Dedicated Mammotomography System with Unique Arbitrary Orbit Capability." Proc. SPIE: Physics of Medical Imaging, 5745(1):609-617 (2005).
    • (2005) Proc. SPIE: Physics of Medical Imaging , vol.5745 , Issue.1 , pp. 609-617
    • McKinley, R.L.1    Brzymialkiewicz, C.N.2    Madhav, P.3    Tornai, M.P.4
  • 11
    • 33745373479 scopus 로고    scopus 로고
    • Preliminary Investigation of Dose for a Dedicated Mammotomography System
    • 11-17 Feb. San Diego, CA
    • RL McKinley, MP Tornai. "Preliminary Investigation of Dose for a Dedicated Mammotomography System." Presented at the 2005 SPIE Medical Imaging Conference, 11-17 Feb. 2006, San Diego, CA
    • (2006) 2005 SPIE Medical Imaging Conference
    • McKinley, R.L.1    Tornai, M.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.