-
2
-
-
33645696556
-
Geant4 developments and applications
-
Allison J et al 2006 Geant4 developments and applications IEEE Trans. Nucl. Sci. 53 270-8
-
(2006)
IEEE Trans. Nucl. Sci.
, vol.53
, Issue.1
, pp. 270-278
-
-
Allison, J.1
Al, E.2
-
3
-
-
39149114100
-
Secondary neutrons in clinical proton radiotherapy: A charged issue
-
Brenner D J and Hall E J 2008 Secondary neutrons in clinical proton radiotherapy: a charged issue Radiother. Oncol. 28 165-70
-
(2008)
Radiother. Oncol.
, vol.86
, Issue.2
, pp. 165-170
-
-
Brenner, D.J.1
Hall, E.J.2
-
4
-
-
30844465932
-
Therapeutic step and shoot proton beam spot-scanning with a multi-leaf collimator: A Monte Carlo study
-
Bues M, Newhauser W D, Titt U and Smith A R 2005 Therapeutic step and shoot proton beam spot-scanning with a multi-leaf collimator: a Monte Carlo study Radiat. Prot. Dosim. 115 164-9
-
(2005)
Radiat. Prot. Dosim.
, vol.115
, Issue.1-4
, pp. 164-169
-
-
Bues, M.1
Newhauser, W.D.2
Titt, U.3
Smith, A.R.4
-
5
-
-
33751197281
-
Neutron dose in scattered and scanned proton beams: In regard to Eric J Hall (Int. J. Radiat. Oncol. Biol. Phys. 2006; 65:1-7)
-
Gottschalk B 2006 Neutron dose in scattered and scanned proton beams: in regard to Eric J Hall (Int. J. Radiat. Oncol. Biol. Phys. 2006; 65:1-7) Int. J. Radiat. Oncol. Biol. Phys. 66 1594 author reply 5
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.66
, Issue.5
, pp. 1594
-
-
Gottschalk, B.1
-
6
-
-
0033795042
-
General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams
-
Grusell E and Medin J 2000 General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams Phys. Med. Biol. 45 2573-82
-
(2000)
Phys. Med. Biol.
, vol.45
, Issue.9
, pp. 2573-2582
-
-
Grusell, E.1
Medin, J.2
-
7
-
-
33645973559
-
Intensity-modulated radiation therapy, protons, and the risk of second cancers
-
Hall E J 2006 Intensity-modulated radiation therapy, protons, and the risk of second cancers Int. J. Radiat. Oncol. Biol. Phys. 65 1-7
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.65
, Issue.1
, pp. 1-7
-
-
Hall, E.J.1
-
8
-
-
34548276465
-
The impact of protons on the incidence of second malignancies in radiotherapy
-
Hall E 2007 The impact of protons on the incidence of second malignancies in radiotherapy Technol. Cancer Res. Treat. 6 31-4
-
(2007)
Technol. Cancer Res. Treat.
, vol.6
, pp. 31-34
-
-
Hall, E.1
-
9
-
-
17844399274
-
Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma
-
Herault J, Iborra N, Serrano B and Chauvel P 2005 Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma Med. Phys. 32 910-9
-
(2005)
Med. Phys.
, vol.32
, Issue.4
, pp. 910-919
-
-
Herault, J.1
Iborra, N.2
Serrano, B.3
Chauvel, P.4
-
10
-
-
0029902095
-
A pencil beam algorithm for proton dose calculations
-
Hong L, Goitein M, Bucciolini M, Comiskey R, Gottschalk B, Rosenthal S, Serago C and Urie M 1996 A pencil beam algorithm for proton dose calculations Phys. Med. Biol. 41 1305-30
-
(1996)
Phys. Med. Biol.
, vol.41
, Issue.8
, pp. 1305-1330
-
-
Hong, L.1
Goitein, M.2
Bucciolini, M.3
Comiskey, R.4
Gottschalk, B.5
Rosenthal, S.6
Serago, C.7
Urie, M.8
-
11
-
-
33748949882
-
Extended collimator model for pencil-beam dose calculation in proton radiotherapy
-
Kanematsu N, Akagi T, Takatani Y, Yonai S, Sakamoto H and Yamashita H 2006 Extended collimator model for pencil-beam dose calculation in proton radiotherapy Phys. Med. Biol. 51 4807-17
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.19
, pp. 4807-4817
-
-
Kanematsu, N.1
Akagi, T.2
Takatani, Y.3
Yonai, S.4
Sakamoto, H.5
Yamashita, H.6
-
12
-
-
39049165022
-
Experimental test of Monte Carlo proton transport at grazing incidence in GEANT4, FLUKA and MCNPX
-
Kimstrand P, Tilly N, Ahnesjo A and Traneus E 2008 Experimental test of Monte Carlo proton transport at grazing incidence in GEANT4, FLUKA and MCNPX Phys. Med. Biol. 53 1115-29
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.4
, pp. 1115-1129
-
-
Kimstrand, P.1
Tilly, N.2
Ahnesjo, A.3
Traneus, E.4
-
13
-
-
34249071653
-
A beam source model for scanned proton beams
-
Kimstrand P, Traneus E, Ahnesjo A, Grusell E, Glimelius B and Tilly N 2007 A beam source model for scanned proton beams Phys. Med. Biol. 52 3151-68
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.11
, pp. 3151-3168
-
-
Kimstrand, P.1
Traneus, E.2
Ahnesjo, A.3
Grusell, E.4
Glimelius, B.5
Tilly, N.6
-
14
-
-
0034090459
-
Development of a compact proton scanning system in Uppsala with a moveable second magnet
-
Lorin S, Grusell E, Tilly N, Medin J, Blom M, Ziemann V, Reistad D and Glimelius B 2000 Development of a compact proton scanning system in Uppsala with a moveable second magnet Phys. Med. Biol. 45 1151-63
-
(2000)
Phys. Med. Biol.
, vol.45
, Issue.5
, pp. 1151-1163
-
-
Lorin, S.1
Grusell, E.2
Tilly, N.3
Medin, J.4
Blom, M.5
Ziemann, V.6
Reistad, D.7
Glimelius, B.8
-
15
-
-
0031861573
-
A technique for the quantitative evaluation of dose distributions
-
Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61
-
(1998)
Med. Phys.
, vol.25
, Issue.5
, pp. 656-661
-
-
Low, D.A.1
Harms, W.B.2
Mutic, S.3
Purdy, J.A.4
-
16
-
-
33751200134
-
In regards to Hall: Intensity-modulated radiation therapy, protons, and the risk of second cancers (Int. J. Radiat. Oncol. Biol. Phys. 2006; 65:1-7)
-
Macklis R 2006 In regards to Hall: intensity-modulated radiation therapy, protons, and the risk of second cancers (Int. J. Radiat. Oncol. Biol. Phys. 2006; 65:1-7) Int. J. Radiat. Oncol. Biol. Phys. 66 1593-4 author reply 5
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.66
, Issue.5
, pp. 1593-1594
-
-
MacKlis, R.1
-
17
-
-
33745667980
-
Neutron scattered dose equivalent to a fetus from proton radiotherapy of the mother
-
Mesoloras G, Sandison G A, Stewart R D, Farr J B and Hsi W C 2006 Neutron scattered dose equivalent to a fetus from proton radiotherapy of the mother Med. Phys. 33 2479-90
-
(2006)
Med. Phys.
, vol.33
, Issue.7
, pp. 2479-2490
-
-
Mesoloras, G.1
Sandison, G.A.2
Stewart, R.D.3
Farr, J.B.4
Hsi, W.C.5
-
18
-
-
0032440084
-
Monte Carlo method to study the proton fluence for treatment planning
-
Paganetti H 1998 Monte Carlo method to study the proton fluence for treatment planning Med. Phys. 25 2370-5
-
(1998)
Med. Phys.
, vol.25
, Issue.12
, pp. 2370-2375
-
-
Paganetti, H.1
-
19
-
-
33751190753
-
Neutron dose in proton radiation therapy: In regard to Eric J Hall (Int. J. Radiat. Oncol. Biol. Phys. 2006; 65:1-7)
-
Paganetti H, Bortfeld T and Delaney T F 2006 Neutron dose in proton radiation therapy: in regard to Eric J Hall (Int. J. Radiat. Oncol. Biol. Phys. 2006; 65:1-7) Int. J. Radiat. Oncol. Biol. Phys. 66 1594-5 author reply 5
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.66
, Issue.5
, pp. 1594-1595
-
-
Paganetti, H.1
Bortfeld, T.2
Delaney, T.F.3
-
20
-
-
23744490002
-
Calculations of neutron dose equivalent exposures from range-modulated proton therapy beams
-
Polf J C and Newhauser W D 2005 Calculations of neutron dose equivalent exposures from range-modulated proton therapy beams Phys. Med. Biol. 50 3859-73
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.16
, pp. 3859-3873
-
-
Polf, J.C.1
Newhauser, W.D.2
-
21
-
-
0029018867
-
Dose calculations in proton beams: Range straggling corrections and energy scaling
-
Russell K R, Grusell E and Montelius A 1995 Dose calculations in proton beams: range straggling corrections and energy scaling Phys. Med. Biol. 40 1031-43
-
(1995)
Phys. Med. Biol.
, vol.40
, Issue.6
, pp. 1031-1043
-
-
Russell, K.R.1
Grusell, E.2
Montelius, A.3
-
22
-
-
33750493272
-
The impact of IMRT and proton radiotherapy on secondary cancer incidence
-
Schneider U, Lomax A, Pemler P, Besserer J, Ross D, Lombriser N and Kaser-Hotz B 2006 The impact of IMRT and proton radiotherapy on secondary cancer incidence Strahlenther. Onkol. 182 647-52
-
(2006)
Strahlenther. Onkol.
, vol.182
, Issue.11
, pp. 647-652
-
-
Schneider, U.1
Lomax, A.2
Pemler, P.3
Besserer, J.4
Ross, D.5
Lombriser, N.6
Kaser-Hotz, B.7
-
23
-
-
33751190291
-
Incorporation of the aperture thickness in proton pencil-beam dose calculations
-
Slopsema R L and Kooy H M 2006 Incorporation of the aperture thickness in proton pencil-beam dose calculations Phys. Med. Biol. 51 5441-53
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.21
, pp. 5441-5453
-
-
Slopsema, R.L.1
Kooy, H.M.2
-
24
-
-
47649105897
-
The use of a miniature multileaf collimator in stereotactic proton therapy (AAPM 2005 abstract)
-
Slopsema R L, Paganetti H, Kooy H, Bussiere M, Sisterson J, Flanz J and Bortfeld T 2005 The use of a miniature multileaf collimator in stereotactic proton therapy (AAPM 2005 abstract) Med. Phys. 32 2088
-
(2005)
Med. Phys.
, vol.32
, Issue.6
, pp. 2088
-
-
Slopsema, R.L.1
Paganetti, H.2
Kooy, H.3
Bussiere, M.4
Sisterson, J.5
Flanz, J.6
Bortfeld, T.7
-
25
-
-
27144440053
-
A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations
-
Soukup M, Fippel M and Alber M 2005 A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations Phys. Med. Biol. 50 5089-104
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.21
, pp. 5089-5104
-
-
Soukup, M.1
Fippel, M.2
Alber, M.3
-
26
-
-
34248233059
-
Development and verification of the pulsed scanned proton beam at the Svedberg Laboratory in Uppsala
-
Tilly N, Grusell E, Kimstrand P, Lorin S, Gajewski K, Pettersson M, Backlund A and Glimelius B 2007 Development and verification of the pulsed scanned proton beam at The Svedberg Laboratory in Uppsala Phys. Med. Biol. 52 2741-54
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.10
, pp. 2741-2754
-
-
Tilly, N.1
Grusell, E.2
Kimstrand, P.3
Lorin, S.4
Gajewski, K.5
Pettersson, M.6
Backlund, A.7
Glimelius, B.8
-
27
-
-
38049178648
-
Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method
-
Titt U, Zheng Y, Vassiliev O N and Newhauser W D 2008 Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method Phys. Med. Biol. 53 487-504
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.2
, pp. 487-504
-
-
Titt, U.1
Zheng, Y.2
Vassiliev, O.N.3
Newhauser, W.D.4
-
29
-
-
41849131460
-
Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms
-
Zacharatou Jarlskog C, Lee C, Bolch W E, Xu X G and Paganetti H 2008 Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms Phys. Med. Biol. 53 693-717
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.3
, pp. 693-717
-
-
Zacharatou Jarlskog, C.1
Lee, C.2
Bolch, W.E.3
Xu, X.G.4
Paganetti, H.5
-
30
-
-
38049006939
-
Monte Carlo simulations of neutron spectral fluence, radiation weighting factor and ambient dose equivalent for a passively scattered proton therapy unit
-
Zheng Y, Fontenot J, Taddei P, Mirkovic D and Newhauser W 2008 Monte Carlo simulations of neutron spectral fluence, radiation weighting factor and ambient dose equivalent for a passively scattered proton therapy unit Phys. Med. Biol. 53 187-201
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.1
, pp. 187-201
-
-
Zheng, Y.1
Fontenot, J.2
Taddei, P.3
Mirkovic, D.4
Newhauser, W.5
-
31
-
-
34547121203
-
Monte Carlo study of neutron dose equivalent during passive scattering proton therapy
-
Zheng Y, Newhauser W, Fontenot J, Taddei P and Mohan R 2007 Monte Carlo study of neutron dose equivalent during passive scattering proton therapy Phys. Med. Biol. 52 4481-96
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.15
, pp. 4481-4496
-
-
Zheng, Y.1
Newhauser, W.2
Fontenot, J.3
Taddei, P.4
Mohan, R.5
|