메뉴 건너뛰기




Volumn 20, Issue 4, 2004, Pages 601-611

Assessment of lung perfusion impairment in patients with pulmonary artery-occlusive and chronic obstructive pulmonary diseases with noncontrast electrocardiogram-gated fast-spin-echo perfusion MR imaging

Author keywords

Chronic obstructive pulmonary disease; Electrocardiogram gating; Lung perfusion; Magnetic resonance (MR) imaging; Pulmonary embolism

Indexed keywords

GADOLINIUM PENTETATE; MACROSALB TC 99M; XENON 133;

EID: 4744352031     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20150     Document Type: Article
Times cited : (23)

References (40)
  • 1
    • 0032588556 scopus 로고    scopus 로고
    • Tc-99m Technegas ventilation and perfusion lung scintigraphy for the diagnosis of pulmonary embolus
    • Howarth DM, Lau L, Thomas PA, Allen LW. Tc-99m Technegas ventilation and perfusion lung scintigraphy for the diagnosis of pulmonary embolus. J Nucl Med 1999;40:579-584.
    • (1999) J Nucl Med , vol.40 , pp. 579-584
    • Howarth, D.M.1    Lau, L.2    Thomas, P.A.3    Allen, L.W.4
  • 2
    • 0032743184 scopus 로고    scopus 로고
    • Single-photon emission tomography of a computerized model of pulmonary embolism
    • Magnussen JS, Palmer AW, Bush V, et al. Single-photon emission tomography of a computerized model of pulmonary embolism. Eur J Nucl Med 1999;26:1430-1438.
    • (1999) Eur J Nucl Med , vol.26 , pp. 1430-1438
    • Magnussen, J.S.1    Palmer, A.W.2    Bush, V.3
  • 3
    • 0036855626 scopus 로고    scopus 로고
    • Is a lung perfusion scan obtained by using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism?
    • Collait JP, Roelants V, Vanpee D, at al. Is a lung perfusion scan obtained by using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism? Nucl Med Commun 2002;23:1107-1113.
    • (2002) Nucl Med Commun , vol.23 , pp. 1107-1113
    • Collait, J.P.1    Roelants, V.2    Vanpee, D.3
  • 4
    • 0033935356 scopus 로고    scopus 로고
    • Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: Assessment with Tc-99m-MAA perfusion and dynamic Xe-133 SPET
    • Suga K, Kume N, Matsunaga N, et al. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with Tc-99m-MAA perfusion and dynamic Xe-133 SPET. Eur J Nucl Med 2000;27:800-806.
    • (2000) Eur J Nucl Med , vol.27 , pp. 800-806
    • Suga, K.1    Kume, N.2    Matsunaga, N.3
  • 5
    • 0034222630 scopus 로고    scopus 로고
    • Correlation of pulmonary perfusion volume analysis with pulmonary function in emphysema
    • Jap
    • Kaneta T, Yamazaki T, Maruoka S, et al. Correlation of pulmonary perfusion volume analysis with pulmonary function in emphysema. Kaku Igaku 2000;37:359-364 [Jap].
    • (2000) Kaku Igaku , vol.37 , pp. 359-364
    • Kaneta, T.1    Yamazaki, T.2    Maruoka, S.3
  • 6
    • 0032929484 scopus 로고    scopus 로고
    • Prospective comparison of MR lung perfusion and lung scintigraphy
    • Berthezene Y, Croisille P, Wiart M, et al. Prospective comparison of MR lung perfusion and lung scintigraphy. J Magn Reson Imaging 1999;9:61-68.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 61-68
    • Berthezene, Y.1    Croisille, P.2    Wiart, M.3
  • 8
    • 0033923377 scopus 로고    scopus 로고
    • 3He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging
    • 3He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging. Magn Reson Med 2000;44:1-4.
    • (2000) Magn Reson Med , vol.44 , pp. 1-4
    • Viallon, M.1    Berthezene, Y.2    Decorps, M.3
  • 9
    • 0026689524 scopus 로고
    • Contrast-enhanced MR imaging of the lung: Assessments of ventilation and perfusion
    • Berthezene Y, Vexler V, Clement O, et al. Contrast-enhanced MR imaging of the lung: assessments of ventilation and perfusion. Radiology 1992;183:667-672.
    • (1992) Radiology , vol.183 , pp. 667-672
    • Berthezene, Y.1    Vexler, V.2    Clement, O.3
  • 12
    • 0034081476 scopus 로고    scopus 로고
    • A closed-chest pulmonary artery occlusion/reperfusion model in the pig. Detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging
    • Amundsen T, Kvaerness J, Aadahl P, et al. A closed- chest pulmonary artery occlusion/ reperfusion model in the pig. Detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging. Invest Radiol 2000;35:295-303.
    • (2000) Invest Radiol , vol.35 , pp. 295-303
    • Amundsen, T.1    Kvaerness, J.2    Aadahl, P.3
  • 13
    • 0036240070 scopus 로고    scopus 로고
    • Regional lung functional impairment in acute airway obstruction and pulmonary embolic dog models assessed with gadolinium-based aerosol ventilation and perfusion magnetic resonance imaging
    • Suga K, Ogasawara N, Okada M, Matsunaga N, Arai M. Regional lung functional impairment in acute airway obstruction and pulmonary embolic dog models assessed with gadolinium-based aerosol ventilation and perfusion magnetic resonance imaging. Invest Radiol 2002;37:281-291.
    • (2002) Invest Radiol , vol.37 , pp. 281-291
    • Suga, K.1    Ogasawara, N.2    Okada, M.3    Matsunaga, N.4    Arai, M.5
  • 14
    • 0038383241 scopus 로고    scopus 로고
    • Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion. Initial results
    • Fink C, Bock M, Puderbach M, Schmahl A, Delorme S. Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion. Initial results. Invest Radiol 2003;38:482-488.
    • (2003) Invest Radiol , vol.38 , pp. 482-488
    • Fink, C.1    Bock, M.2    Puderbach, M.3    Schmahl, A.4    Delorme, S.5
  • 15
    • 0036270776 scopus 로고    scopus 로고
    • Prediction of postoperative pulmonary function using perfusion magnetic resonance imaging of the lung
    • Iwasawa T, Saito K, Ogawa N, Ishiwa N, Kurihara H. Prediction of postoperative pulmonary function using perfusion magnetic resonance imaging of the lung. J Magn Reson Imaging 2002;15:685-692.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 685-692
    • Iwasawa, T.1    Saito, K.2    Ogawa, N.3    Ishiwa, N.4    Kurihara, H.5
  • 16
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 1999;9:483-487.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2
  • 17
    • 0033964957 scopus 로고    scopus 로고
    • Detection of regional pulmonary perfusion deficit of the occluded lung using arterial spin labeling in magnetic resonance imaging
    • Mai VM, Hagspiel KD, Altes T, Goode AR, Williams MB, Berr SS. Detection of regional pulmonary perfusion deficit of the occluded lung using arterial spin labeling in magnetic resonance imaging. J Magn Reson Imaging 2000;11:97-102.
    • (2000) J Magn Reson Imaging , vol.11 , pp. 97-102
    • Mai, V.M.1    Hagspiel, K.D.2    Altes, T.3    Goode, A.R.4    Williams, M.B.5    Berr, S.S.6
  • 18
    • 0036829118 scopus 로고    scopus 로고
    • Potential of noncontrast electrocardiogram-gated half-Fourier fast-spin-echo magnetic resonance imaging to monitor dynamically altered perfusion in regional lung
    • Suga K, Ogasawara N, Munemasa O, Hara A, Matsunaga N. Potential of noncontrast electrocardiogram-gated half-Fourier fast-spin-echo magnetic resonance imaging to monitor dynamically altered perfusion in regional lung. Invest Radiol 2002;37:615-625.
    • (2002) Invest Radiol , vol.37 , pp. 615-625
    • Suga, K.1    Ogasawara, N.2    Munemasa, O.3    Hara, A.4    Matsunaga, N.5
  • 19
    • 0036084985 scopus 로고    scopus 로고
    • Lung perfusion impairments in pulmonary embolic and airway obstruction with noncontrast MR imaging
    • Suga K, Ogasawara N, Okada M, Tsukuda T, Matsunaga N, Miyazaki M. Lung perfusion impairments in pulmonary embolic and airway obstruction with noncontrast MR imaging. J Appl Physiol 2002;92:2439-2451.
    • (2002) J Appl Physiol , vol.92 , pp. 2439-2451
    • Suga, K.1    Ogasawara, N.2    Okada, M.3    Tsukuda, T.4    Matsunaga, N.5    Miyazaki, M.6
  • 21
    • 0033755110 scopus 로고    scopus 로고
    • Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo
    • Miyazaki M, Sugiura S, Tateishi F, Wada F, Kasai Y, Abe H. Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo. J Magn Reson Imaging 2000;12:776-783.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 776-783
    • Miyazaki, M.1    Sugiura, S.2    Tateishi, F.3    Wada, F.4    Kasai, Y.5    Abe, H.6
  • 23
    • 0030901730 scopus 로고    scopus 로고
    • Contributions of pulmonary perfusion and ventilation to heterogeneity in V(A)/Q measured by PET
    • Treppo S, Mijailovich SM, Venegas JG. Contributions of pulmonary perfusion and ventilation to heterogeneity in V(A)/Q measured by PET. J Appl Physiol 1997;82:1163-1176.
    • (1997) J Appl Physiol , vol.82 , pp. 1163-1176
    • Treppo, S.1    Mijailovich, S.M.2    Venegas, J.G.3
  • 24
    • 78651150557 scopus 로고
    • Distribution of blood flow in isolated lung: Relation to vascular and alveolar pressure
    • West JB, Dollery CT, Naimark A. Distribution of blood flow in isolated lung: relation to vascular and alveolar pressure. J Appl Physiol 1964;19:713-724.
    • (1964) J Appl Physiol , vol.19 , pp. 713-724
    • West, J.B.1    Dollery, C.T.2    Naimark, A.3
  • 25
    • 0003150027 scopus 로고
    • Structure and function
    • West JB. editor. Baltimore: Wilkins and Wilkins
    • West JB. Structure and function. In: West JB. editor. Respiratory physiology - the essentials. 5th edition. Baltimore: Wilkins and Wilkins: 1995. p 1-10.
    • (1995) Respiratory Physiology - The Essentials. 5th Edition , pp. 1-10
    • West, J.B.1
  • 26
    • 0028355616 scopus 로고
    • Interrelationships between regional blood flow, blood volume, and ventilation in supine humans
    • Brudin LH, Rhodes CG, Valind SO, Jones T, Hughes JMB. Interrelationships between regional blood flow, blood volume, and ventilation in supine humans. J Appl Physiol 1994;76:1205-1210.
    • (1994) J Appl Physiol , vol.76 , pp. 1205-1210
    • Brudin, L.H.1    Rhodes, C.G.2    Valind, S.O.3    Jones, T.4    Hughes, J.M.B.5
  • 27
    • 0023868613 scopus 로고
    • Effect of body posture on spatial distribution of pulmonary blood flow
    • Hakim TS, Dean GW, Lisbona R. Effect of body posture on spatial distribution of pulmonary blood flow. J Appl Physiol 1988;64:1160-1170.
    • (1988) J Appl Physiol , vol.64 , pp. 1160-1170
    • Hakim, T.S.1    Dean, G.W.2    Lisbona, R.3
  • 29
    • 0032938791 scopus 로고    scopus 로고
    • Demonstration of gravity-dependent lung perfusion with contrast-enhanced magnetic resonance imaging
    • Stock KW, Chen Q, Levin D, Hatabu H, Edelman RR. Demonstration of gravity-dependent lung perfusion with contrast-enhanced magnetic resonance imaging. J Magn Reson Imaging 1999;9:557-561.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 557-561
    • Stock, K.W.1    Chen, Q.2    Levin, D.3    Hatabu, H.4    Edelman, R.R.5
  • 30
    • 0014751188 scopus 로고
    • Effect of body position on vertical distribution of pulmonary blood flow
    • Reed JH, Wood EH. Effect of body position on vertical distribution of pulmonary blood flow. J Appl Physiol 1979;28:303-311.
    • (1979) J Appl Physiol , vol.28 , pp. 303-311
    • Reed, J.H.1    Wood, E.H.2
  • 31
    • 0035928783 scopus 로고    scopus 로고
    • Development of a noninvasive ultrasound color M-mode means of estimating pulmonary vascular resistance in pediatric pulmonary hypertension: Mathematical analysis, in vitro validation, and preliminary clinical studies
    • Shandas R, Weinberg C, Ivy DD, et al. Development of a noninvasive ultrasound color M-mode means of estimating pulmonary vascular resistance in pediatric pulmonary hypertension: mathematical analysis, in vitro validation, and preliminary clinical studies. Circulation 2001;104:908-913.
    • (2001) Circulation , vol.104 , pp. 908-913
    • Shandas, R.1    Weinberg, C.2    Ivy, D.D.3
  • 34
    • 0008553923 scopus 로고
    • The capillary network of normal and emphysematous human lungs studied by injections of Indian ink
    • Reid JA, Heard B. The capillary network of normal and emphysematous human lungs studied by injections of Indian ink. Thorax 1963;18:201-212.
    • (1963) Thorax , vol.18 , pp. 201-212
    • Reid, J.A.1    Heard, B.2
  • 35
    • 0021732246 scopus 로고
    • Enlarged pulmonary arteriovenous vessels in COPD. Another possible mechanism of hypoxemia
    • Miller WC, Heard JG, Linger KM. Enlarged pulmonary arteriovenous vessels in COPD. Another possible mechanism of hypoxemia. Chest 1984;86:704-706.
    • (1984) Chest , vol.86 , pp. 704-706
    • Miller, W.C.1    Heard, J.G.2    Linger, K.M.3
  • 37
    • 0031888040 scopus 로고    scopus 로고
    • Right and left ventricular dysfunction in patients with severe pulmonary disease
    • Vizza CD, Lynch JP, Ochoa LL, Richardson G, Trulock EP. Right and left ventricular dysfunction in patients with severe pulmonary disease. Chest 1998;113:576-583.
    • (1998) Chest , vol.113 , pp. 576-583
    • Vizza, C.D.1    Lynch, J.P.2    Ochoa, L.L.3    Richardson, G.4    Trulock, E.P.5
  • 38
    • 0036828302 scopus 로고    scopus 로고
    • Relationship between lung function ventilation-perfusion inequality and extent of emphysema as assessed by high-resolution computed tomography
    • Sandek K, Bratel T, Lagerstrand L, Resell H. Relationship between lung function ventilation-perfusion inequality and extent of emphysema as assessed by high-resolution computed tomography. Respir Med 2002;96:934-943.
    • (2002) Respir Med , vol.96 , pp. 934-943
    • Sandek, K.1    Bratel, T.2    Lagerstrand, L.3    Resell, H.4
  • 39
    • 4744339574 scopus 로고    scopus 로고
    • Slice tracking and navigator gating provide good image quality without the need for breath-holding in lung imaging
    • Denver. (abstract 954)
    • Rodenburg JB, Smink J, Salverda P, et al. Slice tracking and navigator gating provide good image quality without the need for breath-holding in lung imaging. In: Proceedings of the 8th Annual Meeting of ISMRM. Denver, 2000. (abstract 954).
    • (2000) Proceedings of the 8th Annual Meeting of ISMRM
    • Rodenburg, J.B.1    Smink, J.2    Salverda, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.