메뉴 건너뛰기




Volumn 1130, Issue , 2008, Pages 35-43

Standardization of fluorescence measurements: Criteria for the choice of suitable standards and approaches to fit-for-purpose calibration tools

Author keywords

Calibration, metrology; Day to day intensity standard; Fluorescence microscopy; Fluorescence spectroscopy; Fluorescence standard; Spectral correction

Indexed keywords

CERTIFICATION; CHROMATOPHORE; CONFERENCE PAPER; FIELD EMISSION; FLUORESCENCE; FLUORESCENCE SPECTROSCOPY; INSTRUMENT VALIDATION; MEASUREMENT; PHOTOLUMINESCENCE; QUALITY CONTROL; STANDARDIZATION;

EID: 47349127042     PISSN: 00778923     EISSN: 17496632     Source Type: Book Series    
DOI: 10.1196/annals.1430.018     Document Type: Conference Paper
Times cited : (12)

References (65)
  • 1
    • 77953865084 scopus 로고    scopus 로고
    • Springer Science+Business. New York. Valeur, B. 2002. Molecular Fluorescence. Principles and Applications. Wiley-VCH. Weinheim.
    • Lakowicz, J.R. 2006. Principles of Fluorescence Spectroscopy, 3rd ed. Springer Science+Business. New York. Valeur, B. 2002. Molecular Fluorescence. Principles and Applications. Wiley-VCH. Weinheim.
    • (2006) Principles of Fluorescence Spectroscopy, 3rd Ed.
    • Lakowicz, J.R.1
  • 2
    • 47349129047 scopus 로고    scopus 로고
    • Resch-Genger, U. (. Ed. Springer Series Methods and Applications of Fluorescence, series editor Wolfbeis. O. S., Springer. Heidelberg. In press.
    • Resch-Genger, U. (Ed 2008. Quality Assurance and Standardization in Fluorescence Measurements. Springer Series Methods and Applications of Fluorescence, series editor Wolfbeis. O. S., Springer. Heidelberg. In press.
    • (2008) Quality Assurance and Standardization in Fluorescence Measurements.
  • 5
    • 22044455555 scopus 로고    scopus 로고
    • How to improve quality assurance in fluorometry: Fluorescence-inherent sources of error and suited fluorescence standards
    • Resch-Genger, U., K. Hoffmann, W. Nietfeld, et al. 2005. How to improve quality assurance in fluorometry: fluorescence-inherent sources of error and suited fluorescence standards. J. Fluoresc. 15 : 337 362.
    • (2005) J. Fluoresc. , vol.15 , pp. 337-362
    • Resch-Genger, U.1    Hoffmann, K.2    Nietfeld, W.3
  • 7
    • 0037279631 scopus 로고    scopus 로고
    • Fluorescence: Basic concepts, practical aspects, and some anecdotes
    • &
    • Jameson, D.M., J.C. Croney & P.D.J. Moens. 2003. Fluorescence: basic concepts, practical aspects, and some anecdotes. Methods Enzymol. 360 : 1 43.
    • (2003) Methods Enzymol. , vol.360 , pp. 1-43
    • Jameson, D.M.1    Croney, J.C.2    Moens, P.D.J.3
  • 9
    • 47349089891 scopus 로고    scopus 로고
    • Spectral bandwidth and wavelength accuracy of fluorescence spectrometers
    • ASTM E 388-04 (2004, original version 1972), In
    • ASTM E 388-04 (2004, original version 1972), Spectral bandwidth and wavelength accuracy of fluorescence spectrometers. In : Annual Book of ASTM Standards, vol. 03.06.
    • Annual Book of ASTM Standards , vol.306
  • 10
    • 47349106501 scopus 로고    scopus 로고
    • Linearity of fluorescence measuring system
    • ASTM E 578-01 (2001, original version 1983), In
    • ASTM E 578-01 (2001, original version 1983), Linearity of fluorescence measuring system. In : Annual Book of ASTM Standards, vol. 03.06.
    • Annual Book of ASTM Standards , vol.306
  • 11
    • 47349094370 scopus 로고    scopus 로고
    • Limit of detection of fluorescence of quinine sulfate
    • ASTM E 579-04 (2004, original version 1984), In
    • ASTM E 579-04 (2004, original version 1984), Limit of detection of fluorescence of quinine sulfate. In : Annual Book of ASTM Standards, vol. 03.06.
    • Annual Book of ASTM Standards , vol.306
  • 12
    • 34047189168 scopus 로고
    • Miller, J.N. (. Ed). Standards in Fluorescence Spectrometry. Chapman and Hall. New York.
    • Miller, J.N. (Ed). 1981. Techniques in Visible and Ultraviolet Spectrometry, Vol. 2, Standards in Fluorescence Spectrometry. Chapman and Hall. New York.
    • (1981) Techniques in Visible and Ultraviolet Spectrometry , vol.2
  • 13
    • 84885393188 scopus 로고
    • Reference compounds for fluorescent measurements
    • Eaton, D.F. 1988. Reference compounds for fluorescent measurements. Pure Appl. Chem. 60 : 1107 1114.
    • (1988) Pure Appl. Chem. , vol.60 , pp. 1107-1114
    • Eaton, D.F.1
  • 14
    • 47349131438 scopus 로고
    • Proposal for the standardization of methods of reporting fluorescence emission spectra
    • Chapman, J.H., T. Förster, G. Kortüm, et al. 1963. Proposal for the standardization of methods of reporting fluorescence emission spectra. Appl. Spectrosc. 17 : 171.
    • (1963) Appl. Spectrosc. , vol.17 , pp. 171
    • Chapman, J.H.1    Förster, T.2    Kortüm, G.3
  • 15
    • 22044453760 scopus 로고
    • Colorimetry. 2nd ed.
    • Colorimetry. 1986. CIE-Publ. 15.2, 2nd ed.
    • (1986) CIE-Publ. 15.2
  • 16
    • 0000555552 scopus 로고
    • Recommended methods for the fluorescence decay analysis
    • Eaton, D.F. 1990. Recommended methods for the fluorescence decay analysis. Pure Appl. Chem. 62 : 1631 1648.
    • (1990) Pure Appl. Chem. , vol.62 , pp. 1631-1648
    • Eaton, D.F.1
  • 17
  • 18
    • 3042814814 scopus 로고    scopus 로고
    • Corrected emission spectra and quantum yields for a series of fluorescent compounds in the visible spectral region
    • &
    • Velapoldi, R.A. & H.H. Tonnesen. 2004. Corrected emission spectra and quantum yields for a series of fluorescent compounds in the visible spectral region. J. Fluoresc. 14 : 465 472.
    • (2004) J. Fluoresc. , vol.14 , pp. 465-472
    • Velapoldi, R.A.1    Tonnesen, H.H.2
  • 19
  • 20
    • 0032156765 scopus 로고    scopus 로고
    • Set of secondary emission standards for calibration of the spectral responsivity in emission spectroscopy
    • &
    • Gardecki, J.A. & M. Maroncelli. 1998. Set of secondary emission standards for calibration of the spectral responsivity in emission spectroscopy. Appl. Spectrosc. 52 : 1179 1189.
    • (1998) Appl. Spectrosc. , vol.52 , pp. 1179-1189
    • Gardecki, J.A.1    Maroncelli, M.2
  • 22
    • 47349118760 scopus 로고    scopus 로고
    • Because of radiometric conventions, s implies sλ. The subscript λ denotes per-nanometer or spectral.
    • Because of radiometric conventions, s implies sλ. The subscript λ denotes per-nanometer or spectral.
  • 23
    • 22044449038 scopus 로고    scopus 로고
    • Traceability in fluorometry: Part II. Spectral fluorescence standards
    • Resch-Genger, U., D. Pfeifer, C. Monte, et al. 2005. Traceability in fluorometry: Part II. Spectral fluorescence standards. J. Fluoresc. 15 : 315 336.
    • (2005) J. Fluoresc. , vol.15 , pp. 315-336
    • Resch-Genger, U.1    Pfeifer, D.2    Monte, C.3
  • 24
    • 21844441138 scopus 로고    scopus 로고
    • Traceability in fluorometry: Part I. Physical standards
    • Hollandt, J., D.R. Taubert, J. Seidel, et al. 2005. Traceability in fluorometry: Part I. Physical standards. J. Fluoresc. 15 : 301 314.
    • (2005) J. Fluoresc. , vol.15 , pp. 301-314
    • Hollandt, J.1    Taubert, D.R.2    Seidel, J.3
  • 25
    • 33645510096 scopus 로고    scopus 로고
    • Linking fluorescence measurement to radiometric units
    • Monte, C., U. Resch-Genger, D. Pfeifer, et al. 2006. Linking fluorescence measurement to radiometric units. Metrologia 43 : 89 93.
    • (2006) Metrologia , vol.43 , pp. 89-93
    • Monte, C.1    Resch-Genger, U.2    Pfeifer, D.3
  • 26
    • 34147166057 scopus 로고    scopus 로고
    • For simplicity reasons, the term fluorescence is used not in its strictly photochemical sense describing the spontaneous emission of radiation (luminescence) from an excited molecular entity with retention of spin multiplicity, but as a synonym for (photo)luminescence.
    • Braslavsky, S.E. 2007. For simplicity reasons, the term fluorescence is used not in its strictly photochemical sense describing the spontaneous emission of radiation (luminescence) from an excited molecular entity with retention of spin multiplicity, but as a synonym for (photo)luminescence. Glossary of terms used in photochemistry, 3rd edition (IUPAC Recommendations 2006). Pure Appl. Chem. 79 : 293 465.
    • (2007) Pure Appl. Chem. , vol.79 , pp. 293-465
    • Braslavsky, S.E.1
  • 27
    • 22044449446 scopus 로고
    • Under the sensitivity specification for a fluorescence spectrophotometer
    • Froehlich, P. 1989. Under the sensitivity specification for a fluorescence spectrophotometer. Int. Lab. 42 44.
    • (1989) Int. Lab. , pp. 42-44
    • Froehlich, P.1
  • 28
    • 22044442226 scopus 로고
    • The measurement of sensitivity in fluorescence spectroscopy
    • &
    • Kovach, R.J. & W.M. Peterson. 1994. The measurement of sensitivity in fluorescence spectroscopy. Am. Lab. 32G 32K.
    • (1994) Am. Lab.
    • Kovach, R.J.1    Peterson, W.M.2
  • 29
    • 0036143097 scopus 로고    scopus 로고
    • Fluorescence polarization standards for high-throughput screening and imaging
    • &
    • Thompson, R.B., I. Gryczynski & J. Malicka. 2002. Fluorescence polarization standards for high-throughput screening and imaging. BioTechniques 32 : 34 41.
    • (2002) BioTechniques , vol.32 , pp. 34-41
    • Thompson, R.B.1    Gryczynski, I.2    Malicka, J.3
  • 30
    • 33847620267 scopus 로고    scopus 로고
    • Fluorescence lifetime standards for time and frequency domain fluorescence spectroscopy
    • Boens, N., W. Qin, N. Basaric, et al. 2007. Fluorescence lifetime standards for time and frequency domain fluorescence spectroscopy. Anal. Chem. 79 : 2137 2149.
    • (2007) Anal. Chem. , vol.79 , pp. 2137-2149
    • Boens, N.1    Qin, W.2    Basaric, N.3
  • 31
    • 21844433172 scopus 로고    scopus 로고
    • Pitfalls and their remedies in time-resolved fluorescence spectroscopy and microscopy
    • &
    • vandeVen, M., M. Ameloot, B. Valeur & N. Boens. 2005. Pitfalls and their remedies in time-resolved fluorescence spectroscopy and microscopy. J. Fluoresc. 15 : 377 413.
    • (2005) J. Fluoresc. , vol.15 , pp. 377-413
    • Vandeven, M.1    Ameloot, M.2    Valeur, B.3    Boens, N.4
  • 36
    • 68049094419 scopus 로고    scopus 로고
    • Need for and metrological approaches towards standardization of fluorescence measurements from the view of national metrology institutes
    • In. U. Resch-Genger, Ed. Springer. Berlin, in press.
    • DeRose, P.C., L. Wang, A.K. Gaigalas, et al. 2008. Need for and metrological approaches towards standardization of fluorescence measurements from the view of national metrology institutes. In Quality Assurance and Standardization of Fluorescence Measurements. U. Resch-Genger, Ed. Springer. Berlin, in press.
    • (2008) Quality Assurance and Standardization of Fluorescence Measurements.
    • Derose, P.C.1    Wang, L.2    Gaigalas, A.K.3
  • 37
    • 47349099325 scopus 로고    scopus 로고
    • This equals emission spectra that are independent of excitation wavelength and excitation spectra that are independent of emission wavelength.
    • This equals emission spectra that are independent of excitation wavelength and excitation spectra that are independent of emission wavelength.
  • 38
    • 47349115400 scopus 로고    scopus 로고
    • The stringency of this requirement depends on the spatial resolution of the respective photoluminescence technique.
    • The stringency of this requirement depends on the spatial resolution of the respective photoluminescence technique.
  • 39
    • 0041134814 scopus 로고
    • Uniformity of quantum efficiency of single and trap-configured silicon photodiodes
    • &
    • White, M.G. & A. Bittar. 1993. Uniformity of quantum efficiency of single and trap-configured silicon photodiodes. Metrologia 30 : 361 364.
    • (1993) Metrologia , vol.30 , pp. 361-364
    • White, M.G.1    Bittar, A.2
  • 40
    • 47349093839 scopus 로고    scopus 로고
    • Nearly isotropic emitters with r of approximately. ≤ 0.05 render polarizers dispensable, whereas for devices or materials revealing a partly or strongly polarized emission, such as organic fluorophores embedded into a solid matrix, use without polarizers results in enlarged calibration uncertainties; see also ref. 21.
    • Nearly isotropic emitters with r of approximately ≤ 0.05 render polarizers dispensable, whereas for devices or materials revealing a partly or strongly polarized emission, such as organic fluorophores embedded into a solid matrix, use without polarizers results in enlarged calibration uncertainties; see also ref. 21.
  • 41
    • 35248857834 scopus 로고    scopus 로고
    • Characterization of standard reference material 2941, uranyl-ion-doped glass, spectral correction standard for fluorescence
    • DeRose, P.C., M.V. Smith, K.D. Mielenz, et al. 2008. Characterization of standard reference material 2941, uranyl-ion-doped glass, spectral correction standard for fluorescence. J. Lumin., 128 (2 257 266.
    • (2008) J. Lumin. , vol.128 , Issue.2 , pp. 257-266
    • Derose, P.C.1    Smith, M.V.2    Mielenz, K.D.3
  • 44
    • 0003492094 scopus 로고
    • International Organization for Standardization (ISO). ISBN 92-67-10188-9, 1st ed. Geneva.
    • International Organization for Standardization (ISO). 1995. Guide to the expression of uncertainty in measurement. ISBN 92-67-10188-9, 1st ed. Geneva.
    • (1995) Guide to the Expression of Uncertainty in Measurement.
  • 46
    • 47349102379 scopus 로고    scopus 로고
    • Federal Institute for Materials Research and Testing (BAM). Certificates of analysis, Certified Reference Material BAM-F001, BAM-F002, BAM-F003, BAM-F004, and BAM-F001. Spectral fluorescence standard for the determination of the relative spectral responsivity of fluorescence instruments within its emission range. Certification of emission spectra in 1 nm-intervals. The corresponding product numbers from Sigma-Aldrich for the standards are 97003-1KT-F for the Calibration Kit and 72594, 23923, 96158, 74245, and 94053 for BAM-F001, BAM-F002, BAM-F003, BAM-F004, and BAM-F005, respectively.
    • Federal Institute for Materials Research and Testing (BAM). 2006. Certificates of analysis, Certified Reference Material BAM-F001, BAM-F002, BAM-F003, BAM-F004, and BAM-F001. Spectral fluorescence standard for the determination of the relative spectral responsivity of fluorescence instruments within its emission range. Certification of emission spectra in 1 nm-intervals. The corresponding product numbers from Sigma-Aldrich for the standards are 97003-1KT-F for the Calibration Kit and 72594, 23923, 96158, 74245, and 94053 for BAM-F001, BAM-F002, BAM-F003, BAM-F004, and BAM-F005, respectively.
    • (2006)
  • 47
    • 47349126984 scopus 로고
    • National Bureau of Standards (NBS). Certificate of analysis. Standard Reference Material 936, quinine sulfate dihydrate.
    • National Bureau of Standards (NBS). 1979. Certificate of analysis. Standard Reference Material 936, quinine sulfate dihydrate.
    • (1979)
  • 49
    • 47349109741 scopus 로고    scopus 로고
    • National Institute of Standards and Technology (NIST) (. Certificate of analysis, Standard Reference Materials 2940 and 2941, Relative intensity correction standard for fluorescence spectroscopy: Orange (SRM 2940) and green emission (SRM 2941). Certification of emission spectra in 1 nm-intervals.
    • National Institute of Standards and Technology (NIST) (2006) Certificate of analysis, Standard Reference Materials 2940 and 2941, Relative intensity correction standard for fluorescence spectroscopy: Orange (SRM 2940) and green emission (SRM 2941). Certification of emission spectra in 1 nm-intervals.
    • (2006)
  • 50
    • 47349100899 scopus 로고    scopus 로고
    • Standard practice for testing homogeneity of materials for development of reference materials
    • ASTM E 826-85 (1996, orginal version 1985), In
    • ASTM E 826-85 (1996, orginal version 1985), Standard practice for testing homogeneity of materials for development of reference materials. In : Annual Book of ASTM Standards, vol. 03.06.
    • Annual Book of ASTM Standards , vol.306
  • 51
    • 47349104243 scopus 로고    scopus 로고
    • In some publications, the term technical spectra is also used for corrected spectra; for example, see ref. 20.
    • In some publications, the term technical spectra is also used for corrected spectra; for example, see ref. 20.
  • 52
    • 0021372552 scopus 로고
    • Nomenclature, symbols, units and their usage in spectrochemical analysis VI: Molecular luminescence spectroscopy
    • Melhuish, W.H. 1984. Nomenclature, symbols, units and their usage in spectrochemical analysis VI: molecular luminescence spectroscopy. Pure Appl. Chem. 56 (2 231 245.
    • (1984) Pure Appl. Chem. , vol.56 , Issue.2 , pp. 231-245
    • Melhuish, W.H.1
  • 53
    • 0017814344 scopus 로고
    • Refraction correction for fluorescence spectra of aqueous solutions
    • Mielenz, K.D. 1978. Refraction correction for fluorescence spectra of aqueous solutions. Appl. Opt. 17 : 2875 2876.
    • (1978) Appl. Opt. , vol.17 , pp. 2875-2876
    • Mielenz, K.D.1
  • 54
    • 33745967214 scopus 로고    scopus 로고
    • The calibration kit spectral fluorescence standards: A simple tool for the standardization of the spectral characteristics of fluorescence instruments
    • Pfeifer, D., K. Hoffmann, A. Hoffmann, et al. 2006. The calibration kit spectral fluorescence standards: a simple tool for the standardization of the spectral characteristics of fluorescence instruments. J. Fluoresc. 16 : 581 587.
    • (2006) J. Fluoresc. , vol.16 , pp. 581-587
    • Pfeifer, D.1    Hoffmann, K.2    Hoffmann, A.3
  • 55
    • 84864463431 scopus 로고    scopus 로고
    • Standards in fluorescence spectroscopy: Simple tool for the characterization of fluorescence instruments
    • & pp.
    • Hoffmann, K., C. Monte, D. Pfeifer & U. Resch-Genger. 2005. Standards in fluorescence spectroscopy: simple tool for the characterization of fluorescence instruments. GIT Laboratory Journal, pp. 29 31.
    • (2005) GIT Laboratory Journal , pp. 29-31
    • Hoffmann, K.1    Monte, C.2    Pfeifer, D.3    Resch-Genger, U.4
  • 56
    • 1842622962 scopus 로고    scopus 로고
    • National Institute of Standards and Technology.
    • National Institute of Standards and Technology. NIST Handbook of Basic Atomic Spectroscopic Data. http://www.physics.nist.gov/PhysRefData/Handbook/ index.html.
    • NIST Handbook of Basic Atomic Spectroscopic Data
  • 58
    • 47349123621 scopus 로고    scopus 로고
    • Calibration light source CAL-2000, MIKROPACK GmbH (. or Ocean Optics, Inc. http://www.oceanoptics.com)
    • Calibration light source CAL-2000, MIKROPACK GmbH (http://www.mikropack. de) or Ocean Optics, Inc http://www.oceanoptics.com).
  • 59
    • 47349112005 scopus 로고    scopus 로고
    • Certain commercial equipment, instruments, or materials are identified in this chapter to foster understanding. Such identification does not imply recommendation or endorsement by the Federal Institute for Materials Research and Testing (BAM), nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.
    • Certain commercial equipment, instruments, or materials are identified in this chapter to foster understanding. Such identification does not imply recommendation or endorsement by the Federal Institute for Materials Research and Testing (BAM), nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.
  • 60
    • 22044451559 scopus 로고
    • Standard sample for calibrating wavelength scales of spectral fluorometers
    • &
    • Lifshitz, I.T. & M.L. Meilman. 1989. Standard sample for calibrating wavelength scales of spectral fluorometers. Sov. J. Opt. Technol. 55 : 487 492.
    • (1989) Sov. J. Opt. Technol. , vol.55 , pp. 487-492
    • Lifshitz, I.T.1    Meilman, M.L.2
  • 61
    • 47349122846 scopus 로고    scopus 로고
    • Photon Technology International Inc. (. DYAG. FA-2036.
    • Photon Technology International Inc. (DYAG FA-2036.
  • 62
    • 33745953714 scopus 로고    scopus 로고
    • Simple tool for the standardization of confocal spectral imaging systems
    • & pp.
    • Hoffmann, K., U. Resch-Genger & R. Nitschke. 2005. Simple tool for the standardization of confocal spectral imaging systems. GIT Imaging & Microscopy, pp. 18 20.
    • (2005) GIT Imaging & Microscopy , pp. 18-20
    • Hoffmann, K.1    Resch-Genger, U.2    Nitschke, R.3
  • 63
    • 36248951125 scopus 로고    scopus 로고
    • Fluorescence reference materials used for optical and biophotonic applications
    • Engel, A., C. Otterman, J. Klahn, et al. 2007. Fluorescence reference materials used for optical and biophotonic applications. Proc. SPIE 6628 : 662815 662822.
    • (2007) Proc. SPIE , vol.6628 , pp. 662815-662822
    • Engel, A.1    Otterman, C.2    Klahn, J.3
  • 64
    • 47349092007 scopus 로고    scopus 로고
    • The lifetimes of the different RE species are in the upper micro- to millisecond range.
    • The lifetimes of the different RE species are in the upper micro- to millisecond range.
  • 65
    • 70349548966 scopus 로고    scopus 로고
    • Comparability of fluorescence microscopy data and need for instrument characterization of spectral scanning microscopes
    • & In. U. Resch-Genger, Ed. Springer. Berlin, in press.
    • Hoffmann, K., U. Resch-Genger & R. Nitschke. 2008. Comparability of fluorescence microscopy data and need for instrument characterization of spectral scanning microscopes. In Quality Assurance and Standardization of Fluorescence Measurements. U. Resch-Genger, Ed. Springer. Berlin, in press.
    • (2008) Quality Assurance and Standardization of Fluorescence Measurements.
    • Hoffmann, K.1    Resch-Genger, U.2    Nitschke, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.