메뉴 건너뛰기




Volumn 23, Issue 7, 2008, Pages 853-858

Analysis of biomechanical effect of stem-end design in revision TKA using Digital Korean model

Author keywords

Finite element model; Revision total knee arthroplasty; Stem design; Stem end pain

Indexed keywords

ARCHITECTURAL DESIGN; BIOMECHANICS; COATING TECHNIQUES; FINITE DIFFERENCE METHOD; MECHANICS; MODAL ANALYSIS; PHOTOACOUSTIC EFFECT; PRESSURE; STANDARDS; STRESS CONCENTRATION; STRESSES; THREE DIMENSIONAL;

EID: 46749085883     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2008.01.010     Document Type: Article
Times cited : (24)

References (25)
  • 1
    • 12144263432 scopus 로고    scopus 로고
    • A parametric analysis of fixation post shape in tibial knee prostheses
    • Au A.G., Liggins A.B., Raso V.J., and Amirfazli A. A parametric analysis of fixation post shape in tibial knee prostheses. Med. Eng. Phys. 27 (2005) 123-134
    • (2005) Med. Eng. Phys. , vol.27 , pp. 123-134
    • Au, A.G.1    Liggins, A.B.2    Raso, V.J.3    Amirfazli, A.4
  • 2
    • 33947593021 scopus 로고    scopus 로고
    • Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements
    • Au A.G., Raso V.J., Liggins A.B., and Amirfazli A. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. J. Biomech. 40 (2007) 1410-1416
    • (2007) J. Biomech. , vol.40 , pp. 1410-1416
    • Au, A.G.1    Raso, V.J.2    Liggins, A.B.3    Amirfazli, A.4
  • 3
    • 46749091121 scopus 로고
    • Preliminary results of press-fit condylar knee
    • Bae D.K., Ahn J.S., and Nah K.N. Preliminary results of press-fit condylar knee. Korean Knee Soc. 1 (1989) 132-138
    • (1989) Korean Knee Soc. , vol.1 , pp. 132-138
    • Bae, D.K.1    Ahn, J.S.2    Nah, K.N.3
  • 4
    • 0032696478 scopus 로고    scopus 로고
    • Pain at the end of the stem after revision total knee arthroplasty
    • Barrack R.L., Rorabeck C., Burt M., and Sawhney J. Pain at the end of the stem after revision total knee arthroplasty. Clin. Orthop. 367 (1999) 216-225
    • (1999) Clin. Orthop. , vol.367 , pp. 216-225
    • Barrack, R.L.1    Rorabeck, C.2    Burt, M.3    Sawhney, J.4
  • 5
    • 5344256906 scopus 로고    scopus 로고
    • The effect of stem design on end of stem pain in revision total knee arthroplasty
    • Barrack R.L., Stanley T., Burt M., and Hopkins S. The effect of stem design on end of stem pain in revision total knee arthroplasty. J. Arthroplasty 19 (2004) 119-124
    • (2004) J. Arthroplasty , vol.19 , pp. 119-124
    • Barrack, R.L.1    Stanley, T.2    Burt, M.3    Hopkins, S.4
  • 6
    • 0031890246 scopus 로고    scopus 로고
    • Principles of revision total knee arthroplasty
    • Bourne R.B., and Crawford H.A. Principles of revision total knee arthroplasty. Orthop. Clin. North Am. 29 (1998) 331-337
    • (1998) Orthop. Clin. North Am. , vol.29 , pp. 331-337
    • Bourne, R.B.1    Crawford, H.A.2
  • 7
    • 0021153444 scopus 로고
    • Tibial component fixation in deficient tibial bone stock
    • Brooks P.J., Walker P.S., and Scott R.D. Tibial component fixation in deficient tibial bone stock. Clin. Orthop. 184 (1984) 302-308
    • (1984) Clin. Orthop. , vol.184 , pp. 302-308
    • Brooks, P.J.1    Walker, P.S.2    Scott, R.D.3
  • 8
    • 33748680570 scopus 로고    scopus 로고
    • Racial/ethnic differences in preferences for total knee replacement surgery
    • Byrne M.M., Souchek J., Richardson M., and Suarez-Almazor M. Racial/ethnic differences in preferences for total knee replacement surgery. J. Clin. Epidemiol. 59 (2006) 1078-1086
    • (2006) J. Clin. Epidemiol. , vol.59 , pp. 1078-1086
    • Byrne, M.M.1    Souchek, J.2    Richardson, M.3    Suarez-Almazor, M.4
  • 9
    • 5344235412 scopus 로고    scopus 로고
    • The optimal strategy for stable tibial fixation in revision total knee arthroplasty
    • Conditt M.A., Parsley B.S., Alexander J.W., Doherty S.D., and Noble P.C. The optimal strategy for stable tibial fixation in revision total knee arthroplasty. J. Arthroplasty 19 S2 (2004) 113-118
    • (2004) J. Arthroplasty , vol.19 , Issue.SUPPL.2 , pp. 113-118
    • Conditt, M.A.1    Parsley, B.S.2    Alexander, J.W.3    Doherty, S.D.4    Noble, P.C.5
  • 10
    • 0026339364 scopus 로고
    • Results of revision total knee arthroplasty associated with significant bone loss
    • Elia E.A., and Lotke P.A. Results of revision total knee arthroplasty associated with significant bone loss. Clin. Orthop. 271 (1991) 114-121
    • (1991) Clin. Orthop. , vol.271 , pp. 114-121
    • Elia, E.A.1    Lotke, P.A.2
  • 11
    • 0242441675 scopus 로고    scopus 로고
    • Stem fixation in revision total knee arthroplasty: a comparative analysis
    • Fehring T.K., Odum S., Olekson C., et al. Stem fixation in revision total knee arthroplasty: a comparative analysis. Clin. Orthop. 416 (2003) 217-224
    • (2003) Clin. Orthop. , vol.416 , pp. 217-224
    • Fehring, T.K.1    Odum, S.2    Olekson, C.3
  • 12
    • 12344305251 scopus 로고    scopus 로고
    • Load-shift - numerical evaluation of a new design philosophy for uncemented hip prostheses
    • Goetzen N., Lampe F., Nassut R., and Morlock M.M. Load-shift - numerical evaluation of a new design philosophy for uncemented hip prostheses. J. Biomech. 38 (2005) 595-604
    • (2005) J. Biomech. , vol.38 , pp. 595-604
    • Goetzen, N.1    Lampe, F.2    Nassut, R.3    Morlock, M.M.4
  • 14
    • 10444255467 scopus 로고    scopus 로고
    • Explicit finite element modeling of total knee replacement mechanics
    • Halloran J.P., Petrella A.J., and Rullkoetter P.J. Explicit finite element modeling of total knee replacement mechanics. J. Biomech. 38 (2005) 323-331
    • (2005) J. Biomech. , vol.38 , pp. 323-331
    • Halloran, J.P.1    Petrella, A.J.2    Rullkoetter, P.J.3
  • 15
    • 36048942194 scopus 로고    scopus 로고
    • Ethnic differences in preoperative function of patients undergoing total knee arthroplasty
    • Joshy S., Datta A., Perera A., Thomas B., Gogi N., and Singh B.K. Ethnic differences in preoperative function of patients undergoing total knee arthroplasty. Int. Orthop. 30 (2006) 426-428
    • (2006) Int. Orthop. , vol.30 , pp. 426-428
    • Joshy, S.1    Datta, A.2    Perera, A.3    Thomas, B.4    Gogi, N.5    Singh, B.K.6
  • 16
    • 16644386170 scopus 로고    scopus 로고
    • Race, ethnicity, insurance coverage and preoperative status of hip and knee surgical patients
    • Lavernia C.J., Lee D., Sierra R.J., and Gomez-Marin O. Race, ethnicity, insurance coverage and preoperative status of hip and knee surgical patients. J. Arthroplasty 19 (2004) 978-985
    • (2004) J. Arthroplasty , vol.19 , pp. 978-985
    • Lavernia, C.J.1    Lee, D.2    Sierra, R.J.3    Gomez-Marin, O.4
  • 17
    • 16244385444 scopus 로고    scopus 로고
    • Aseptic failure in total knee arthroplasty
    • Engh G.A., and Rorabeck C.H. (Eds), Lippincott, Williams & Wilkins, US
    • Maloney W.J. Aseptic failure in total knee arthroplasty. In: Engh G.A., and Rorabeck C.H. (Eds). Revision Total Knee Arthroplasty (1997), Lippincott, Williams & Wilkins, US
    • (1997) Revision Total Knee Arthroplasty
    • Maloney, W.J.1
  • 18
    • 46749084098 scopus 로고    scopus 로고
    • Analysis of the shape of the tibial tray in total knee arthroplasty using a three dimension finite element model
    • Miyoshi S., Takahashi T., Ohtani M., Yamamoto H., and Kameyama K. Analysis of the shape of the tibial tray in total knee arthroplasty using a three dimension finite element model. Clin. Biomech. 38 (2005) 595-604
    • (2005) Clin. Biomech. , vol.38 , pp. 595-604
    • Miyoshi, S.1    Takahashi, T.2    Ohtani, M.3    Yamamoto, H.4    Kameyama, K.5
  • 19
    • 0014698584 scopus 로고
    • The mechanics of the knee joint in relation to normal walking
    • Morrison J.B. The mechanics of the knee joint in relation to normal walking. J. Biomech. 3 (1970) 51-61
    • (1970) J. Biomech. , vol.3 , pp. 51-61
    • Morrison, J.B.1
  • 21
    • 0038386323 scopus 로고    scopus 로고
    • Influence of the stiffness of bone defect implants on the mechanical conditions at the interface finite element analysis with contact
    • Simon U., Augat P., Ignatius A., and Claes L. Influence of the stiffness of bone defect implants on the mechanical conditions at the interface finite element analysis with contact. J. Biomech. 36 (2003) 1079-1086
    • (2003) J. Biomech. , vol.36 , pp. 1079-1086
    • Simon, U.1    Augat, P.2    Ignatius, A.3    Claes, L.4
  • 22
    • 0031454020 scopus 로고    scopus 로고
    • The effect of tibial stem design on component micromotion in knee arthroplasty
    • Stern S.H., Wills R.D., and Gilbert J.L. The effect of tibial stem design on component micromotion in knee arthroplasty. Clin. Orthop. 345 (1997) 44-52
    • (1997) Clin. Orthop. , vol.345 , pp. 44-52
    • Stern, S.H.1    Wills, R.D.2    Gilbert, J.L.3
  • 23
    • 34047195369 scopus 로고    scopus 로고
    • Anthropometry of the medial tibial condyle to design the tibial component for unicondylar knee arthroplasty for the Korean population
    • Surendran S., Kwak D.S., Lee U.Y., Park S.E., Gopinathan P., Han S.H., and Han C.W. Anthropometry of the medial tibial condyle to design the tibial component for unicondylar knee arthroplasty for the Korean population. Knee Surg. Sports Traumatol. Arthrosc. 15 (2007) 436-442
    • (2007) Knee Surg. Sports Traumatol. Arthrosc. , vol.15 , pp. 436-442
    • Surendran, S.1    Kwak, D.S.2    Lee, U.Y.3    Park, S.E.4    Gopinathan, P.5    Han, S.H.6    Han, C.W.7
  • 24
    • 0030987956 scopus 로고    scopus 로고
    • Fatigue failure of cancellous bone: a possible cause of implant migration and loosening
    • Taylor M., and Tanner K.E. Fatigue failure of cancellous bone: a possible cause of implant migration and loosening. J. Bone Joint Surg. 79B (1997) 181-182
    • (1997) J. Bone Joint Surg. , vol.79 B , pp. 181-182
    • Taylor, M.1    Tanner, K.E.2
  • 25
    • 0032053031 scopus 로고    scopus 로고
    • Finite element analysis of the implanted proximal tibia: a relationship between the initial cancellous bone stresses and implant migration
    • Taylor M., Tanner K.E., and Freeman M.A. Finite element analysis of the implanted proximal tibia: a relationship between the initial cancellous bone stresses and implant migration. J. Biomech. 31 (1998) 303-310
    • (1998) J. Biomech. , vol.31 , pp. 303-310
    • Taylor, M.1    Tanner, K.E.2    Freeman, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.