메뉴 건너뛰기




Volumn 78, Issue 2, 2008, Pages 141-145

Changes in transthoracic impedance during sequential biphasic defibrillation

Author keywords

Biphasic; Cardioversion; Defibrillation; Resuscitation; Transthoracic impedance

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOVERSION; CLINICAL TRIAL; DEFIBRILLATION; DEFIBRILLATOR; FEMALE; HEART ARREST; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HUMAN; INFLAMMATION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SKIN BLOOD FLOW; STATISTICAL SIGNIFICANCE; TREATMENT OUTCOME;

EID: 46649084594     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2008.02.024     Document Type: Article
Times cited : (18)

References (14)
  • 1
    • 0028806652 scopus 로고
    • Impedance to defibrillation countershock: does an optimal impedance exist?
    • KenKnight B.H., Eyuboglu B.M., and Ideker R.E. Impedance to defibrillation countershock: does an optimal impedance exist?. Pacing Clin Electrophysiol 18 11 (1995) 2068-2087
    • (1995) Pacing Clin Electrophysiol , vol.18 , Issue.11 , pp. 2068-2087
    • KenKnight, B.H.1    Eyuboglu, B.M.2    Ideker, R.E.3
  • 3
    • 0016949566 scopus 로고
    • Transthoracic impedance to direct current discharge: effect of repeated countershocks
    • Dahl C.F., Ewy G.A., Ewy M.D., and Thomas E.D. Transthoracic impedance to direct current discharge: effect of repeated countershocks. Med Instrum 10 3 (1976) 151-154
    • (1976) Med Instrum , vol.10 , Issue.3 , pp. 151-154
    • Dahl, C.F.1    Ewy, G.A.2    Ewy, M.D.3    Thomas, E.D.4
  • 4
    • 1242269825 scopus 로고    scopus 로고
    • Differential contribution of skin impedance and thoracic volume to transthoracic impedance during external defibrillation
    • Deakin C.D., Sado D.M., Petley G.W., and Clewlow F. Differential contribution of skin impedance and thoracic volume to transthoracic impedance during external defibrillation. Resuscitation 60 2 (2004) 171-174
    • (2004) Resuscitation , vol.60 , Issue.2 , pp. 171-174
    • Deakin, C.D.1    Sado, D.M.2    Petley, G.W.3    Clewlow, F.4
  • 5
    • 0026440191 scopus 로고
    • Guidelines for advanced life support
    • ALS Working Party of the ERC. Guidelines for advanced life support. Resuscitation 24 (1992) 111-122
    • (1992) Resuscitation , vol.24 , pp. 111-122
    • ALS Working Party of the ERC1
  • 6
    • 28544439505 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2005. Section 3. Electrical therapies: automated external defibrillators, defibrillation, cardioversion and pacing
    • Deakin C.D., and Nolan J.P. European resuscitation council guidelines for resuscitation 2005. Section 3. Electrical therapies: automated external defibrillators, defibrillation, cardioversion and pacing. Resuscitation 67 Suppl. 1 (2005) S25-S37
    • (2005) Resuscitation , vol.67 , Issue.SUPPL. 1
    • Deakin, C.D.1    Nolan, J.P.2
  • 7
    • 33751217742 scopus 로고    scopus 로고
    • A randomised controlled trial of the effect of biphasic or monophasic waveform on the incidence and severity of cutaneous burns following external direct current cardioversion
    • Ambler J.J., and Deakin C.D. A randomised controlled trial of the effect of biphasic or monophasic waveform on the incidence and severity of cutaneous burns following external direct current cardioversion. Resuscitation 71 3 (2006) 293-300
    • (2006) Resuscitation , vol.71 , Issue.3 , pp. 293-300
    • Ambler, J.J.1    Deakin, C.D.2
  • 8
    • 0000606835 scopus 로고    scopus 로고
    • Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care-an international consensus on science
    • ILCOR. Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care-an international consensus on science. Resuscitation 46 1-3 (2000) 111
    • (2000) Resuscitation , vol.46 , Issue.1-3 , pp. 111
    • ILCOR1
  • 9
    • 2542480866 scopus 로고    scopus 로고
    • The incidence and severity of cutaneous burns following external DC cardioversion
    • Ambler J.J., Sado D.M., Zideman D.A., and Deakin C.D. The incidence and severity of cutaneous burns following external DC cardioversion. Resuscitation 61 3 (2004) 281-288
    • (2004) Resuscitation , vol.61 , Issue.3 , pp. 281-288
    • Ambler, J.J.1    Sado, D.M.2    Zideman, D.A.3    Deakin, C.D.4
  • 10
    • 0021170163 scopus 로고
    • Advance prediction of transthoracic impedance in human defibrillation and cardioversion: importance of impedance in determining the success of low-energy shocks
    • Kerber R.E., Kouba C., Martins J., et al. Advance prediction of transthoracic impedance in human defibrillation and cardioversion: importance of impedance in determining the success of low-energy shocks. Circulation 70 2 (1984) 303-308
    • (1984) Circulation , vol.70 , Issue.2 , pp. 303-308
    • Kerber, R.E.1    Kouba, C.2    Martins, J.3
  • 11
    • 0026059926 scopus 로고
    • Factors determining success and energy requirements for cardioversion of atrial fibrillation: revised version
    • Dalzell G.W., Anderson J., and Adgey A.A. Factors determining success and energy requirements for cardioversion of atrial fibrillation: revised version. Q J Med 78 285 (1991) 85-95
    • (1991) Q J Med , vol.78 , Issue.285 , pp. 85-95
    • Dalzell, G.W.1    Anderson, J.2    Adgey, A.A.3
  • 12
    • 0024464088 scopus 로고
    • Electrode pad size, transthoracic impedance and success of external ventricular defibrillation
    • Dalzell G.W., Cunningham S.R., Anderson J., and Adgey A.A. Electrode pad size, transthoracic impedance and success of external ventricular defibrillation. Am J Cardiol 64 12 (1989) 741-744
    • (1989) Am J Cardiol , vol.64 , Issue.12 , pp. 741-744
    • Dalzell, G.W.1    Cunningham, S.R.2    Anderson, J.3    Adgey, A.A.4
  • 13
    • 0037221245 scopus 로고    scopus 로고
    • Transthoracic impedance does not decrease with rapidly repeated countershocks in a swine cardiac arrest model
    • Niemann J.T., Garner D., and Lewis R.J. Transthoracic impedance does not decrease with rapidly repeated countershocks in a swine cardiac arrest model. Resuscitation 56 1 (2003) 91-95
    • (2003) Resuscitation , vol.56 , Issue.1 , pp. 91-95
    • Niemann, J.T.1    Garner, D.2    Lewis, R.J.3
  • 14
    • 0032955613 scopus 로고    scopus 로고
    • The effect of shock configuration and delivered energy on defibrillation impedance
    • Olsovsky M.R., Shorofsky S.R., and Gold M.R. The effect of shock configuration and delivered energy on defibrillation impedance. Pacing Clin Electrophysiol 22 (1999) 165-168
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 165-168
    • Olsovsky, M.R.1    Shorofsky, S.R.2    Gold, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.