Volumn 22, Issue 1 II, 1999, Pages 165-168

The effect of shock configuration and delivered energy on defibrillation impedance

Author keywords

Active pectoral lead system; Defibrillation impedance; Transvenous defibrillation

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; DEFIBRILLATION; DEFIBRILLATOR; ENERGY; FEMALE; HEART ATRIUM FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; MALE;

EID: 0032955613     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1999.tb00325.x     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0023736265 scopus 로고
    • Current-based versus energy based ventricular defibrillation: A prospective study
    • Lerman BB, DiMarco JP, Haines DE. Current-based versus energy based ventricular defibrillation: A prospective study. J Am Coll Cardiol 1988; 12:1259-1264.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 1259-1264
    • Lerman, B.B.1    DiMarco, J.P.2    Haines, D.E.3
  • 2
    • 0023938827 scopus 로고
    • Energy current, and success in defibrillation and cardioversion: Clinical studies using an automated impedance-based method of energy adjustment
    • Kerber, RE, Martins JB, Kienzle MG, et al. Energy current, and success in defibrillation and cardioversion: Clinical studies using an automated impedance-based method of energy adjustment. Circulation 1988; 77:1038-1046.
    • (1988) Circulation , vol.77 , pp. 1038-1046
    • Kerber, R.E.1    Martins, J.B.2    Kienzle, M.G.3
  • 3
    • 0030041075 scopus 로고    scopus 로고
    • Biphasic defibrillation using a single capacitor with large capacitance: Reduction of peak voltages and ICD device size
    • Block M, Hammel D, Bocker D, et al. Biphasic Defibrillation using a single capacitor with large capacitance: Reduction of peak voltages and ICD device size. PACE 1996; 19:207-214.
    • (1996) PACE , vol.19 , pp. 207-214
    • Block, M.1    Hammel, D.2    Bocker, D.3
  • 4
    • 0028850822 scopus 로고
    • A prospective randomized comparison in humans of biphasic waveform 60-°F and 120 °F capacitance pulses using a unipolar defibrillation system
    • Bardy GH, Poole JE, Kudenchuk PJ, et al. A prospective randomized comparison in humans of biphasic waveform 60-°F and 120 °F capacitance pulses using a unipolar defibrillation system. Circulation 1995; 91:91-95.
    • (1995) Circulation , vol.91 , pp. 91-95
    • Bardy, G.H.1    Poole, J.E.2    Kudenchuk, P.J.3
  • 5
    • 0019497010 scopus 로고
    • Transthoracic resistance in human defibrillation: Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure
    • Kerber RE, Grayzel J, Hoye R, et al. Transthoracic resistance in human defibrillation: Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure. Circulation 1981; 63:676-682.
    • (1981) Circulation , vol.63 , pp. 676-682
    • Kerber, R.E.1    Grayzel, J.2    Hoye, R.3
  • 6
    • 0022380547 scopus 로고
    • The implanted defibrillator: Relation of a defibrillating lead configuration and clinical variables to defibrillation threshold
    • Troup PJ, Chapman PD, Olinger GN, et al. The implanted defibrillator: Relation of a defibrillating lead configuration and clinical variables to defibrillation threshold. J Am Coll Cardiol 1985; 6:1315-1321.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 1315-1321
    • Troup, P.J.1    Chapman, P.D.2    Olinger, G.N.3
  • 7
    • 0025878541 scopus 로고
    • Electrode system influence on biphasic waveform defibrillation efficacy in humans
    • Bardy GH, Troutman C, Johnson G, et al. Electrode system influence on biphasic waveform defibrillation efficacy in humans. Circulation 1991; 84:665-671.
    • (1991) Circulation , vol.84 , pp. 665-671
    • Bardy, G.H.1    Troutman, C.2    Johnson, G.3
  • 8
    • 0029128807 scopus 로고
    • Optimal electrode configuration for pectoral transvenous implantable defibrillator without an active can
    • Swerdlow CD, Davie S, Kass RM, et al. Optimal electrode configuration for pectoral transvenous implantable defibrillator without an active can. Am J Cardiol 1995; 76:370-374.
    • (1995) Am J Cardiol , vol.76 , pp. 370-374
    • Swerdlow, C.D.1    Davie, S.2    Kass, R.M.3
  • 9
    • 0030237562 scopus 로고    scopus 로고
    • The effect of an active pectoral pulse generator shell on defibrillation efficacy with a transvenous lead system
    • Gold MR, Foster AH, Shorofsky SR. The effect of an active pectoral pulse generator shell on defibrillation efficacy with a transvenous lead system. Am J Cardiol 1996; 78:540-543.
    • (1996) Am J Cardiol , vol.78 , pp. 540-543
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 10
    • 0025352387 scopus 로고
    • Utility of low energy test shocks for estimation of cardiac and electrode impedance with implantable defibrillators
    • Leitch JW, Yee R, Klein GJ, et al. Utility of low energy test shocks for estimation of cardiac and electrode impedance with implantable defibrillators. PACE 1990; 13:410-416.
    • (1990) PACE , vol.13 , pp. 410-416
    • Leitch, J.W.1    Yee, R.2    Klein, G.J.3
  • 11
    • 0028301696 scopus 로고
    • Effects of voltage and respiration on impedance in nonthoracotomy defibrillation pathways
    • Swerdlow CD, Kass RM, Hwang C, et al. Effects of voltage and respiration on impedance in nonthoracotomy defibrillation pathways. Am J Cardiol 1994; 73:688-692.
    • (1994) Am J Cardiol , vol.73 , pp. 688-692
    • Swerdlow, C.D.1    Kass, R.M.2    Hwang, C.3
  • 13
    • 0032080562 scopus 로고    scopus 로고
    • Comparison of single- and dual-coil active pectoral defibrillation lead systems
    • Gold MR, Olsovsky MR, Pelini MA, et al. Comparison of single- and dual-coil active pectoral defibrillation lead systems. J Am Coll Cardiol 1998; 313:1391-1394.
    • (1998) J Am Coll Cardiol , vol.313 , pp. 1391-1394
    • Gold, M.R.1    Olsovsky, M.R.2    Pelini, M.A.3
  • 14
    • 0031945621 scopus 로고    scopus 로고
    • Effect of shock polarity on biphasic defibrillation thresholds using an active pectoral lead system
    • Olsovsky MR, Shorofsky, SR, Gold MR. Effect of shock polarity on biphasic defibrillation thresholds using an active pectoral lead system. J Cardiovasc Electrophysiol 1998; 9:350-354.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 350-354
    • Olsovsky, M.R.1    Shorofsky, S.R.2    Gold, M.R.3
  • 15
    • 0030705217 scopus 로고    scopus 로고
    • Induction of atrial fibrillation with low-energy defibrillation shocks in patients with implantable cardioverter defibrillators
    • Florin TJ, Weiss DN, Peters RW, et al. Induction of atrial fibrillation with low-energy defibrillation shocks in patients with implantable cardioverter defibrillators. Am J Cardiol 1997; 80:960-962.
    • (1997) Am J Cardiol , vol.80 , pp. 960-962
    • Florin, T.J.1    Weiss, D.N.2    Peters, R.W.3
  • 16
    • 0019644588 scopus 로고
    • Determining transthoracic impedance, delivered energy and peak current during defibrillation episodes
    • Jones VC, Charbonnier FM, Long P. Determining transthoracic impedance, delivered energy and peak current during defibrillation episodes. Med Instrum 1981; 15:380-382.
    • (1981) Med Instrum , vol.15 , pp. 380-382
    • Jones, V.C.1    Charbonnier, F.M.2    Long, P.3
  • 17
    • 0030221145 scopus 로고    scopus 로고
    • Chronic rise in defibrillation threshold with a hybrid lead system
    • Tummula RV, Riggio DR, Peters RW, et al. Chronic rise in defibrillation threshold with a hybrid lead system. Am J Cardiol 1996; 78:309-312.
    • (1996) Am J Cardiol , vol.78 , pp. 309-312
    • Tummula, R.V.1    Riggio, D.R.2    Peters, R.W.3
  • 18
    • 0031568431 scopus 로고    scopus 로고
    • Chronic rise in monophasic defibrillation thresholds with transvenous lead system
    • Kirk MM, Shorofsky SR, Khalighi K, et al. Chronic rise in monophasic defibrillation thresholds with transvenous lead system. Am J Cardiol 1997; 79:502-505.
    • (1997) Am J Cardiol , vol.79 , pp. 502-505
    • Kirk, M.M.1    Shorofsky, S.R.2    Khalighi, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.